Building Code Review Board
Regular MeetingArlington Heights, IL · May 17, 2023
Agenda
Agenda
Village of Arlington Heights
Building Code Review Board
Community Room
33 S. Arlington Heights Rd, AH 60005
May 17, 2023
6:30 PM
I. CALL TO ORDER
II. ROLL CALL
III. APPROVAL OF MINUTES
A. Approval of the May 11, 2022 Minutes
IV. REPORTS
V. OLD BUSINESS
VI. NEW BUSINESS
A. 519 W Algonquin Rd -Petition for Appeal and Modification
VII. OTHER BUSINESS
VIII.ADJOURNMENT
Persons with disabilities requiring auxiliary aids or services, such as an
American Sign Language interpreter or written materials in accessible
formats, should contact Erin Mercado, at 33 S. Arlington Heights Road,
Arlington Heights, Illinois 60005, emercado@vah.com or (847)368-5793.
Building Code Review Board
5/17/2023
Item: Approval of the May 11, 2022 Minutes
Department: Building & Life Safety
ATTACHMENTS:
Description Type
May 11, 2022 Draft Minutes Minutes
DRAFT
BUILDING CODE REVIEW BOARD
MINUTES OF A MEETING BEFORE THE
VILLAGE OF ARLINGTON HEIGHTS
BUILDING CODE REVIEW BOARD
May 11, 2022
MEMBERS PRESENT: ADMINISTRATION PRESENT:
Richard Bondarowicz, Acting Chairman Jorge Torres, Director of Building & Life Safety
Carl Baldassarra Elliot Eldridge, Assist. Building Official
Richard Bondarowicz Dave Roberts, Division Chief
Pat O’Gorman Patty LeVee, Recording Secretary
Trustee Jim Tinaglia
Other: Keith Moens
SUBJECT: Removal of Amendments to the basic Building & Fire Code
There being a quorum present, the meeting was called to order at 6:02pm.
APPROVAL OF MINUTES
MR. BALDASSARRA MOTIONED TO APPROVE THE NOVEMBER 8, 2021 MINUTES OF THE BCRB.
SECONDED BY TRUSTEE TINALIA, THE MOTION PASSED.
AYES: Mr. Baldassarra, Mr. Bondarowicz, Mr. O’Gorman, Trustee Tinaglia,
ABSENT: Mr. Hutchinson and Mr. Smith
OLD BUSINESS
Acting Chairman, Bondarowicz’ inquired on how the implementation of the roofing permits was
going? Mr. Torres responded that it is going very well. There have been no complaints, on the
opposite there have been several positive comments thanking us for reinstating the roofing
permit requirement for protection of the new homeowner/new residents. The feedback is all
good, there are no issues at all.
NEW BUSINESS
Removal of Varied Amendments to the Municipal Codes
Mr. Torres provided background stating that we use the ICC Building Codes, which is THE
standard building Codes used internationally throughout the world, these Codes have been
tested and challenged by different trades and different entities. Occasionally when we adopt the
new codes, we add amendments. Amendments are something extra than the base code. There
are three amendments we are seeking recommendation to remove. From talking to staff and
through different experiences and conversations with some of our contractors and design
professionals, we found we need to review these again and make sure if they make sense or not.
Mr. Torres added he is not questioning why it was adopted, it may have made sense at that point
when this was included as part of our codes, but we feel that it is not necessary and actually does
more harm than good for the property owner.
Mr. Torres stated the first code is from the IRC, which applies for residential, single-family homes.
The base code only requires a thicker plywood for sheathing 5/8th if the spacing of the rafter is
wider than the normal. However, the amendment as we added was that any kind of spacing for
roofing sheathing requires 5/8th.
Mr. Torres continued, that being sensitive to the markets we have now, and that we do not judge
the quality of the work nor how long the material lasts versus 1/2” versus 5/8th, we all know the
thicker the better is more quality, but that is not our job. Our job is to make sure it meets the
current building codes. That being said, we are seeking to go back to the base code and not
require 5/8th for a detached garage plywood roofing, a 5/8th for a single-family home, just
because whoever put that amendment thought it was better quality work. We all know that
material grades, the higher the intensity, the more quality there will be and it will last longer.
Mr. Torres agrees but stated that it not our job, our job is to make sure that the applicant does
the minimum requirement of the base codes which have been tested already for many years
through the ICC process.
Mr. Baldassarra stated that the language states, shall be a minimum of 5/8” and asked, are we
changing this from ½”. Mr. Torres explained that the base code already requires ½”. We are
going to take out, we are removing that amendment.
Trustee Tinaglia, for the benefit of the audience, stated that these codes are National Codes in a
book all of us use daily. From time to time over his 30 years of business with different building
official of the years, codes get added to and amended. What we are doing tonight is removing a
few of those amendments that maybe do not make sense anymore. Mr. Baldassarra asked for
clarification that these were our local amendments, and we are deleting them. Trustee Tinaglia
stated yes, this is in Chapter 23.
Acting Chairman Bondarowicz suggested to discuss each code separately, and commented that
as a builder, and also involved in the roofing industry, and worked in 70-80 different
communities, this is an odd ball requirement. It is not typical for 5/8th plywood on a roof and with
the cost of lumber where it is at, it is in a way doing a disservice. Ventilation is more important
than the thickness of the plywood. Mr. Torres agreed, adding the key is also that, when do we
inspect this, if it is 5/8th or not? What do you do when the shingles are already installed? We
highly recommend for the Village Board to remove this amendment.
Acting Chairman Bondarowicz discussed voting on each code separately and called for a motion
on this issue. Mr. Baldassarra moved to amend the Village Code to delete the requirement for
2
5/8” roof sheathing in Section R803.2.2.1. Mr. O’Gorman seconded the motion. All in favor,
motion passed.
Mr. Torres introduced the next code item, taken from the IBC, Chapter 30, related to the
elevator. Mr. Torres explained the base code has a standard size for the cabin of the actual
elevator. For some reason or another we added an amendment to make one elevator wider than
what the base code requires for it. He had spoken with the Fire Department on this issue and
presented our recommendation. They reviewed it and agreed, they do not need that wide or big
of an elevator cabin. Mr. Torres continued that this is important because if the applicant is
required to create this type of elevator, it is a whole different scenario in terms of elevator type.
That elevator type will be huge in terms of expenses and we do not have any use for that. Mr.
Torres thanked the Fire Department for their collaboration, they agree the extra space of the
elevator is not needed.
Acting Chairman Bondarowicz asked for comments. Mr. Baldassarra asked, was this an
amendment that said every building had to have at least one elevator this size? Does the base
Code, IBC 3002.4 state if the building is four stories or more, it needs to be this size, but not all
buildings? Mr. Torres explained that what the amendment required is that the size of the
elevator, any elevator, would have to be bigger than what is required. The base code already has
the dimension, which satisfies all usage of all elevators, we do not need a wider or bigger elevator
cabin. Mr. Baldassarra noted this is all about the size, and noted the language that will remain,
requires that size in buildings four stories or more. Division Chief Roberts stated it requires the
fit of the stretcher, as long as we can fit the stretcher, they are good. There are different
configurations but the old language is more specific, they are fine with this.
With no further comments, Acting Chairman Bondarowicz, called for a motion. Mr. Baldassarra
made a motion to approve to delete the requirement to the amendment of 3002.4 from the
Village amendments. Mr. O’Gorman second the motion. All were in favor.
Mr. Torres next presented the Fire Code, Chapter 9 for existing building. The base code
referenced standpipe with the regular Section 905, which is the whole purpose of how to install
a standpipe. We are asking to remove the amendment that was added to the end of that
paragraph. Basically, if someone wants to remove the hose from the standpipe, the different
requirement is needed to remove this hose. Mr. Torres spoke with the Fire Department and they
really do not trust those hoses and prefer having the hose removed and not have it there as a
tool to possibly harm someone down the road. Division Chief Roberts stated the only person
who uses this is someone not trained in fire fighting and this is something they do not particularly
want. They have a rule to never use those hoses and prefer that civilians never use them either.
Mr. Torres added that they are trying to make it easier for the property owner to remove the fire
hoses, there is no purpose of having them there.
Acting Chairman, Richard Bondarowicz called for comments, there were none. Mr. Baldassarra
moved to approve the proposed amendment to 905.12 of the Village amendments. Mr.
O’Gorman second the motion. All were in favor.
3
Discussion
Mr. Torres added that some of these items came through conversations at the stakeholders’
meetings, held quarterly with some of our design professionals and general contractors. One
caller, regarding one of these codes, expressed that just did not make any sense. He then did
talk to other staffing and departments, and all were in agreement to correct and make these
amendments more efficient. Mr. Baldassarra noted he spoke against one of these items long
ago and it did not prevail and now finally it will.
Mr. Torres, on a separate note, thanked the Village for doing the proclamation for the month of
May, making it Building Safety month for the Village. This makes everybody aware of how
important building codes are.
Acting Chairman Bondarowicz in closing commented on how great this was, it is all common
sense. It is common sense that will save money and save lives, it all works. Mr. Torres stated
Building & Life Safety Department tries to be very practical, there are always ways we can
improve things, and encouraged anyone at the table that sees anything that needs improvement
or discussion to bring to his or Elliot’s attention.
There was brief discussion that the Electrical Commission has been eliminated, noting Mr.
Hutchinson (Chairman) from that Commission is now on the Building Code Review Commission.
With no further business, Acting Chairman Bondarowicz motioned to adjourn. Seconded by
Trustee Tinaglia, all were in favor.
The meeting adjourned at 6:24 pm
4
Building Code Review Board
5/17/2023
Item: 519 W Algonquin Rd - Petition for Appeal and Modification
Department: Building & Life Safety
ATTACHMENTS:
Description Type
Application and Petition Presentation