Building Code Review Board
Regular MeetingArlington Heights, IL · November 6, 2024
Agenda
AGENDA
Building Code Review Board
Commissions Room
Arlington Heights Village Hall, 33 S. Arlington Heights Rd., AH 60005
November 6, 2024
6:00 PM
I. CALL TO ORDER
II. ROLL CALL OF MEMBERS
III. APPROVAL OF MINUTES
A. Building Code Review Board 07/24/2023 Meeting Minutes
IV. REPORTS
V. OLD BUSINESS
VI. NEW BUSINESS
A. Chapter 27-102 Text Amendments - Aerial Fire Apparatus Access Roads
B. Chapter 27-102 Text Amendments - Consistency with reference to the Authority
Having Jurisdiction (AHJ)
C. Chapter 23-302 Text Amendments - Certificate of Occupancy
D. Chapter 23-302 & Chapter 27-102 Text Amendments - Discrepancies
E. Chapter 23-702 Text Amendments - Discrepancy
VII. OTHER BUSINESS
VIII. PUBLIC COMMENT
Anyone wishing to speak on a subject not on the Agenda may speak at this time. Please limit
your comments to three minutes.
IX. ADJOURNMENT
Persons with disabilities requiring auxiliary aids or services, such as an American Sign
Language interpreter or written materials in accessible formats, should contact Erin Mercado,
at 33 S. Arlington Heights Road, Arlington Heights, IL 60005, emercado@vah.com or 847/368-
5793.
Packet
AGENDA
Building Code Review Board
Commissions Room
Arlington Heights Village Hall, 33 S. Arlington Heights Rd., AH 60005
November 6, 2024
6:00 PM
I. CALL TO ORDER
II. ROLL CALL OF MEMBERS
III. APPROVAL OF MINUTES
A. Building Code Review Board 07/24/2023 Meeting Minutes
IV. REPORTS
V. OLD BUSINESS
VI. NEW BUSINESS
A. Chapter 27-102 Text Amendments - Aerial Fire Apparatus Access Roads
B. Chapter 27-102 Text Amendments - Consistency with reference to the Authority
Having Jurisdiction (AHJ)
C. Chapter 23-302 Text Amendments - Certificate of Occupancy
D. Chapter 23-302 & Chapter 27-102 Text Amendments - Discrepancies
E. Chapter 23-702 Text Amendments - Discrepancy
VII. OTHER BUSINESS
VIII. PUBLIC COMMENT
Anyone wishing to speak on a subject not on the Agenda may speak at this time. Please limit
your comments to three minutes.
IX. ADJOURNMENT
Persons with disabilities requiring auxiliary aids or services, such as an American Sign
Language interpreter or written materials in accessible formats, should contact Erin Mercado,
at 33 S. Arlington Heights Road, Arlington Heights, IL 60005, emercado@vah.com or 847/368-
5793.
Page 1 of 16
DRAFT
BUILDING CODE REVIEW BOARD
MINUTES OF A MEETING BEFORE THE
VILLAGE OF ARLINGTON HEIGHTS
BUILDING CODE REVIEW BOARD
July 24, 2023
MEMBERS PRESENT: ADMINISTRATION PRESENT:
Richard Bondarowicz, Chairman Pro Tem Jorge Torres, Director of Building & Life Safety
Carl Baldassarra Dave Roberts, Division Chief
Pat O’Gorman Fred Alaimo, Plumbing Inspector
Scott Smith Patty LeVee, Recording Secretary
Trustee Jim Tinaglia
SUBJECT: Removal of amendments and adopting the appendices to the basic Building and Fire
Codes.
There being a quorum present, the meeting was called to order at 6:30pm.
APPROVAL OF MINUTES
TRUSTEE TINAGLIA MOTIONED TO APPROVE THE MINUTES OF THE MAY 17, 2023 MEETING OF
THE BCRB. SECONDED BY PAT O’GORMAN, THE MOTION PASSED.
AYES: Mr. Bondarowicz, Mr. O’Gorman, Trustee Tinaglia,
ABSTAIN: Mr. Baldassarra and Mr. Smith (absent from the May 17th meeting).
OLD BUSINESS
Mr. Torres provided an update as to the status of the last meeting regarding Chez Hotel. Mr.
Torres reported progress as the Petitioner has changed their plan. As requested, 50% of the
drywall of the first floor was removed. The property owners are now leading the project, the
prior project manager has been removed. Upon mutual agreement, the inspection responsibility
has been outsourced to FSCI, who will be responsible for all the inspections. Depending on the
result of their inspection of the first floor, they will request more drywall removal on the 2nd, 3rd,
4th and 5th floor. The 6th floor was framed and they will inspect that as well. Plan reviews have
been submitted as requested. This included the fire protection system, the elevator, the full
building permit, and the backup generator. Mr. Torres stated it appears they are going to get
this project moving forward quicker than anticipated.
1
Page 2 of 16
Mr. Baldassarra asked Mr. Torres why he agreed to allow a 3rd party inspection agency? Mr.
Torres replied that because it was determined that it was to their best benefit as they need more
attention to this project. We are in our peak season and are unable to have our inspectors stay
on site 2 to 3 hours for the type of inspections needed, as the owners want to proceed quickly
on this and obtain occupancy. After discussing this option separately with our staffing and then
the owners, all agreed this is a better option and will provide the attention needed.
Mr. Baldassarra asked if we are spot checking the 3rd party? Mr. Torres replied, yes, and noted
we have worked with the 3rd party before. The contract is with the Village, the expense will be
covered by them, as they agreed. This is strictly for the inside of the building, the architectural,
they will not be involved with engineering, or planning etc.
There was further discussion regarding the need to return to this Board and the many counts
brought up at the May 17th meeting. Mr. Torres explained that the relief they were asking for
has nothing to do with Building Code, it was more a relief of errors from working on the project
without approved drawings. The option for a BCRB meeting is always there if they feel the need.
NEW BUSINESS
CH 27 2018 IFC Adopting
Mr. Torres stated that when the 2018 codes were adopted, part of the base code, the appendixes
were not adopted, making it unenforceable. The two appendixes are Appendix B, which is the
fire code requirement and Appendix C, the fire hydrant locations and distribution. This was
referenced and brought to our attention at a meeting as not adopted, therefor we are
recommending adopting these two appendixes.
Mr. Baldassarra asked if recently, have there been any major issues about complying with fire
flow permits in the Village? Mr. Torres stated there has not, however, we do not have anything
to hang our hat on if it comes up down the road. Mr. Baldassarra noted with the Village having
a pretty good water supply, we shouldn’t have trouble unless it is on a dead end.
Mr. Tinaglia asked, if that were to happen, is there language where the Building Code Official
can make adjustments and rule appropriately? Mr. Torres responded, yes, the Village can do
that.
Mr. Roberts stated there are a couple requirements to have them have more fire flow if the
need arises or allow them to have less.
Chapter 23
Removal of Amendments Related to Plumbing Code
Mr. Torres stated next are two amendments to the Plumbing Code. After research by our
plumbing inspector, Mr. Alaimo, it was found we are the only municipality that has these two
amendments. The first is the grease traps. We require the grease traps to always be installed
2
Page 3 of 16
outside. Through conversation and discussions with other departments as to why this was
adopted, (which was roughly 20 years ago), the intent of this adoption was more for maintenance
issues. Due to having a new maintenance division, Mr. Alaimo and I feel comfortable that with
the team we have for maintenance, this can be addressed separately. Why would we overburden
the restaurant owner or the property owner on installing the grease trap outside if it can easily
be installed inside.
Mr. Torres continued stating, the other amendment is in regards to plumbing fixtures. For some
reason, beginning of Covid, we adopted the amendment to require all medical buildings to have
a hand sink in all rooms. Again, we are the only municipality that has this. In discussion with our
previous plumbing inspector, he thought this was primarily because of Covid. Mr. Alaimo, our
current plumbing inspector, had researched this with the CDC and IDPH regarding the need and
intent. They did not know what the intent was but no, this is more of a burden and overkill. Mr.
Torres stated we are comfortable that this is not needed or required, especially since the State
Plumbing Code does not have it there.
Building Regulations – Article II
Mr. Torres stated that lastly, for some reason for mechanical for new systems, we require to
always install a high and low return. Once again, old houses with a mechanical systems that work
perfectly well with the central return, not having a high and low return in each room, we are the
only municipality that has this amendment. We feel that it is not needed. This is getting into the
design of the furnace. Usually, the furnace will manifest its specification, will instruct how many
returns are needed or the design of it will figure that out. Why would we require something that
is overburden or overkill on this particular amendment? Obviously, it is better, it is more
efficient, no question there, but everything can be better. We need to keep in mind that Building
Codes are the minimum standards. We do not need to force the contractor or home remodeling
to do this, it is sometimes not practical. Having concluded, Mr. Torres opened to discussion on
any of these items.
Mr. Baldassarra commented on the first two items, asking are they consistent with the Il State
Plumbing Code? Mr. Alaimo replied that the first two items are amendments to the Code that
we are taking out. Mr. Baldassarra stated, then what we are proposing now will be consistent.
Mr. Alaimo replied, yes, consistent with the Code.
Mr. Baldassarra next commented on the high and low returns and his personal preference is that
he has it and likes it. Discussion on preference for this ensued. Mr. Torres agreed, stating more
quality is better and it is a better design but we are keeping in mind that this is really the minimum
code. Chairman Bondarowicz agrees that it is more efficient but in all of his experience, Arlington
Heights is the one that enforces this. In two of his current homes this is problematic during the
construction.
Chairman Bondarowicz called for any further comments or questions regarding the
amendments.
3
Page 4 of 16
Mr. Tinaglia commented that it is great and appreciates the research and consideration and
cleaning up of some of these code related matters. There was short discussion on past code
amendments and where we are now.
Chairman Bondawowicz called for a motion as to the removal of these amendments.
MR. BALDASSARRA MOVED TO APPROVE, SECONDED BY MR. O’GORMAN, ALL WERE IN
FAVOR.
OTHER BUSINESS
Mr. Baldassarra inquired about the cycle for the next code upgrade. Mr. Torres commented
that this will be discussed next year.
Chairman Bondarowicz commented on the guidelines for the sprinkler requirement for the
systems for domestic tied in for un-engineered floor joists. There was discussion on this
requirement and the threshold of the square footage of the area, using a 10 x 10 furnace room,
for example.
Mr. Torres stated that for the residential and not for fully sprinklered homes, but just a particular
area, it would not be required by a licensed architect to do that drawing, as long as there are
specs of the coverage of the head. Chairman Bondarowicz was seeking clarification to this in
regards to the Village asking for a document that identifies all of the parts and pieces and
obstructions.
Chairman Bondarowicz next commented in regards to height restrictions on single family homes.
This continues to fester and feels we are pretty much the only community with this requirement.
It seems to be in zoning, not building code. Mr. Torres recalled this coming up during a
stakeholder meeting and thought there should be another meeting and follow up on this,
possibly as soon as September.
With no further comment, Chairman Bondarowicz called to adjourn the meeting.
The meeting adjourned at 7:05pm.
4
Page 5 of 16
Building Code Review Board
11/6/2024
Item: Chapter 27-102 Text Amendments - Aerial Fire Apparatus
Access Roads
Department: Building & Life Safety
Item Description:
The last two editions of the International Fire Code includes an exception to
Section D105.1 which allows noncombustible construction buildings to be
exempt of an aerial fire apparatus access road if fully sprinklered and
includes enclosed stairways with standpipes from the lowest fire
department access to all roof surfaces.
This immediately relates to an upcoming project that recently was approved
for zoning variations, 811 E. Central Rd., The Moorings project.
The addition of this exception is recommended to be presented to the
Village Board for approval of an amendment to the Village of Arlington
Heights Municipal Code.
ATTACHMENTS:
1. 2025-05-13 PHTM -DRAFT_ 2021 IFC Code modification Letter (004)
2. Appendix_D__Fire_Apparatus_Access_Roads
3. 10b_CEX - Fire and Life Safety Exhibit_2024.08.01
4. CLX - Alternate Entrance Landscape Plan
Page 6 of 16
May 13, 2024
Mr. Jorge Torres
Director, C.B.O.
Building & Life Safety Department
Village of Arlington Heights, IL
Dear Mr. Torres –
We are writing in regard to Presbyterian Homes Expansion project.
Village of Arlington Heights is currently applying the 2018 edition of the International
Fire Code in their permit review for this project. And we have been informed that
Perkins Eastman
Village of Arlington Heights plans to adopt the 2021 version of the IFC soon. Architects DPC
In our response to your comments on fire apparatus, we’re currently revising the site
plan layout. The new layout will ensure compliance with the fire apparatus access road
requirements as specified in Section D 101 through D108 of Appendix D in the IFC PERKINSEASTMAN.COM
2018 version.
However, due to the existing site restrictions, this revision will bring forth several
challenges to the project. It includes providing less desirable surface parking near the Boston
entrance for senior residents, a decreased landscape buffer zone between vehicular Charlotte
traffic and residential living spaces, and limited space to incorporate a pedestrian path Chicago
for the senior residents. Costa Mesa
Dallas
Therefore, the project team aims to advocate for the specific application of Section
Dubai
D105.1 of the 2021 IBC, In lieu of the 2018 edition. This section in 2021 IFC provides
an exception to the requirement for an aerial fire apparatus access road. For your Guayaquil
convenience, we have transcribed the requirements of Exception verbiage below, in Los Angeles
italicized blue font. Mumbai
New York
D105.1 Where required” Oakland
Where the vertical distance between the grade plane and the highest roof surface
Pittsburgh
exceeds 30 feet ….
San Francisco
Exception: When approved by the fire code official, Buildings of Type 1A, 1B or IIA
construction equipped throughout with an automatic sprinkler system in Shanghai
accordance with section 903.1.1 and having fire fighter access through an Stamford
enclosed stairway with a class I standpipe from the lower level of fire department Toronto
vehicle access to all roof surfaces. Washington DC
Our interpretation of this section is that since the proposed new IL building is a 1B
construction with an automatic sprinkler system in accordance with 903.1.1 and will
include a Class I standpipe and enclosed stairway from the lower level to the roof, a fire
apparatus access road is deemed unnecessary.
Page 7 of 16
To summarize, we wish to request your approval for granting a building code
modification in which the requirements of the Section D105.1 of the 2021 IFC, in lieu
of the currently adopted 2018 IFC by Village of Arlington heights, would be applied to
the fire apparatus access roads for this project. We view this request as reasonable, as
the parameters of future additions of the code are often referenced in an authority’s
evaluation of a requested variance.
Please let me know if you have any questions or would like to discuss this further.
Prepared by: Reviewed by:
Daniel Wu, AIA, LEED AP BD+C Jerry R. Walleck, AIA, LEED AP
Project Architect Principal
Page 2 of 2
Page 8 of 16
APPENDIX D: FIRE APPARATUS ACCESS ROADS
D105.1 Where required.
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet (9144 mm), approved
aerial fire apparatus access roads shall be provided. For purposes of this section, the highest roof surface shall be
determined by measurement to the eave of a pitched roof, the intersection of the roof to the exterior wall, or the top of
parapet walls, whichever is greater.
Exception: Where approved by the fire code official, buildings of Type IA, Type IB or Type IIA construction equipped
throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and having fire fighter access
through an enclosed stairway with a Class I standpipe from the lowest level of fire department vehicle access to all roof
surfaces.
❖ Aerial apparatus access roads are required where the fire department cannot reach the roof or upper stories with
ground ladders. The Insurance Services Office (ISO) Fire Suppression Rating Schedule suggests that fire departments
carry a 35-foot ground ladder. When setting up a 35-foot ground ladder appropriately, the effective vertical reach of the
ladder is approximately 30 feet; hence the 30-foot requirement within this section. Note that the measurement in this
section is from grade plane to the edge of the roof where the ladder would be placed. If this measurement is greater than
30 feet, then an aerial apparatus access road would be required. The term eave is the most common term used in the
International Building Code® (IBC®) when describing the edge of a peaked roof and is thus used herein. See also the
commentary to the definition of “Grade plane” in Chapter 2.
The exception acknowledges that fire department aerial apparatus access is rarely needed for buildings of Type IA, IB
or IIA construction that is equipped throughout with an automatic sprinkler system, in accordance with NFPA 13, and that
also has firefighter access through an enclosed stair or stair(s) with a Type I standpipe system from the lowest level of
fire department vehicle access to all roof surfaces. Firefighting operations including ventilation can be achieved through
the interior of these buildings using enclosed stairs as means of egress from the hazard area. The requirement for a Class
I standpipe is for fire suppression and fire-fighter protection when operating hoselines at the roof or at a lower floor level.
High-rise buildings are required by IBC Section 403.4.7 to have means for smoke removal. These means do not require
aerial apparatus access.
Copyright © 2024 International Code Council, Inc., or its licensors (ALL RIGHTS RESERVED).
Accessed by Andrew Roskos on 07/02/2024 pursuant to License Agreement with ICC. No further reproduction or distribution
authorized. Any Unauthorized reproduction or distribution is a violation of the federal copyright, and subject to civil and
criminal penalties thereunder.
Page 9 of 16
No. Description Date
Plan Commission
1 07.03.2024
Resubmission
Plan Commission Revision
2 08.01.2024
2
VEHICLE LEGEND
TOPHER M.FIS
CH RI S H
062-063549
REGISTERED
PROFESSIONAL
ENGINEER
OF
I L L I N OI S
EXPIRATIONDATE: 11/30/2025
SEAL
KEY PLAN
The Rookery
209 South LaSalle St., Suite 400
Chicago, IL 60604
T. +1.312.755.1200
F. +1.312.755.1155
Owner:
The Moorings of Arlington Heights
811 E Central Rd, Arlington Heights, IL 60005
847-979-3970
Civil / Site:
Eriksson Engineering Associates
145 Commerce Drive, Suite A, Grayslake, IL 60030
630-296-6259
Landscape:
The Lakota Group
One East Wacker Dr, Suite 2700, Chicago, IL 60601
312-467-5445 x 202
Structural:
Meyer Borgman Johnson
1 N LaSalle St, Suite 3250,Chicago, IL 60602
312-602-0157
Mechanical & Plumbing:
Salas O'Brien
815 S Wabash, Chicago, IL 60605
312-870-5142
Electrical:
Salas O'Brien
815 S Wabash, Chicago, IL 60605
312-870-5142
Elevator Consultant:
Jenkins & Huntington
5 Climax Road, Avon, CT 06001
630-325-4415
Envelope Consultant:
Wiss, Janney, Elstner Associates
10 S LaSalle St, Suite 2600, Chicago IL 60603
312-325-0907
PROJECT TITLE:
Presbyterian Homes -
The Moorings
811 E Central Rd
Arlington Heights, IL 60005
PROJECT No: 102120
DRAWING TITLE:
FIRE & LIFE
SAFETY EXHIBIT
SCALE:
CEX
ISSUED FOR
ISSUED FORPLAN COMMISSION
SCHEMATIC DESIGN
RESUBMITTAL
08.01.2024
06.21.2024
Page 10 of 16
Page 11 of 16
Building Code Review Board
11/6/2024
Item: Chapter 27-102 Text Amendments - Consistency with
reference to the Authority Having Jurisdiction (AHJ)
Department: Building & Life Safety
Item Description:
There are two sections within the Fire Regulations that are not consistent
with whom the AHJ is.
It is recommended that Section 912.2.1 (fire department connections) and
Section D103.4 (dead ends) remove the Fire Chief and replace with the
original IFC text to the Fire Code Official.
ATTACHMENTS:
None
Page 12 of 16
Building Code Review Board
11/6/2024
Item: Chapter 23-302 Text Amendments - Certificate of Occupancy
Department: Building & Life Safety
Item Description:
The new e-permitting software, Enterprise Permitting & Licensing (EPL), has
limitations regarding what information can be added to built-in reports.
Customized reports by 3rd party vendors cost thousands of dollars and
appear not to be supported in the future.
It is recommended that Section 111.2 (certificate issued) add numbers 4, 7,
8, and 12 to the list of deleted items. All of these items are required to be
noted directly on the approved permit drawings. Therefore, this duplicate
information is not needed on the certificate of occupancy.
ATTACHMENTS:
None
Page 13 of 16
Building Code Review Board
11/6/2024
Item: Chapter 23-302 & Chapter 27-102 Text Amendments -
Discrepancies
Department: Building & Life Safety
Item Description:
There are discrepancies between the Building and Fire Regulations due to
several sections that include similar code. The additional amendments noted
in the Building Regulations are not necessary as the International Existing
Building Code covers these code requirements and is written to reduce the
requirements for when sprinklers are required, which was not the intent of
these amendments.
It is recommended that these discrepancies be eliminated and replaced with
text to clarify the requirements.
1. Ch. 23-302: Remove Sections 903-908
1. Delete these sections in their entirety and replace them with the
following:
2. Refer to Chapter 27-102 for the adopted and modified
International Fire Code Sections 903-908.
2. Ch. 23-302: Remove Sections 912
1. Delete these sections in their entirety and replace them with the
following:
2. Refer to Chapter 27-102 for the adopted and modified
International Fire Code Section 912.
3. Ch. 23-302: Remove Section 913.4
1. Delete this section in its entirety and replace it with the
following:
2. Refer to Chapter 27-102 for the adopted and modified
International Fire Code Section 913.4.
4. Ch. 23-302: Remove "" from 901.6.1
1. 901.6.1 Automatic sprinkler systems. Modify this section by
replacing the words "an approved supervising station" with
"Northwest Central Dispatch".
2. Ch. 27-102: Add section to match IBC 901.6.1
5. 903.4.1 Monitoring. Modify this section by replacing the words "an
approved supervising station" with "Northwest Central Dispatch".
Page 14 of 16
ATTACHMENTS:
None
Page 15 of 16
Building Code Review Board
11/6/2024
Item: Chapter 23-702 Text Amendments - Discrepancy
Department: Building & Life Safety
Item Description:
Section 904.1 Automatic sprinkler systems states to replace text that
doesn't exist.
It is recommended to remove this section in its entirety.
ATTACHMENTS:
None
Page 16 of 16