Planning Commission
Regular MeetingPalatine, IL · January 18, 2022
Minutes
VILLAGE OF PALATINE
VILLAGE HALL - COUNCIL CHAMBERS 200 E. WOOD STREET
PALATINE, IL 60067-5339 – (847) 359-9050
http://www.palatine.il.us
PLAN COMMISSION
MINUTES ● JANUARY 18, 2022
Village Hall - Council Chambers Regular Meeting 7:00 PM
I. CALL TO ORDER
Attendee Name Title Status Arrived
Dennis Dwyer Chairman Present
Patrick Noonan Plan Commissioner Absent
Teri Williams Plan Commissioner Present
Eric Friedman Plan Commissioner Absent
Rodney Bettenhausen Plan Commissioner Present
Robert Kolososki Plan Commissioner Present
Stephen Fedota Plan Commissioner Absent
II. APPROVAL OF MINUTES
1. Plan Commission - Regular Meeting - Dec 7, 2021 7:00 PM
RESULT: ACCEPTED AS AMENDED [UNANIMOUS]
MOVER: Teri Williams, Plan Commissioner
SECONDER: Robert Kolososki, Plan Commissioner
AYES: Dwyer, Williams, Bettenhausen, Kolososki
ABSENT: Noonan, Friedman, Fedota
VILLAGE OF PALATINE Page 1
Minutes Plan Commission January 18, 2022
III. PUBLIC HEARING
IV. CASE STAFF STATEMENTS
1. 1101 E. Dundee Road - Planned Development Amendment to the Park Place
Shopping Center Planned Development to allow for the Construction of a New
Multi-Tenant Building; and 2. A Special Use to Permit a Restaurant, with Drive-
Through, as a Tenant in the New Building.
Chairman Dwyer read the notice of public hearing that was published in the Daily
Herald on January 3rd, 2022 and mailed to the owners of the surrounding
properties.
The following petitioner’s exhibits were introduced:
1. Project Narrative & Menu
2. Planned Development Amendment
3. Special Use & Variation Application
4. Plat of Survey
5. Cross Access Easement
6. Public Notice
7. Park Place Planned Development
Sworn in Petitioner: Mr. Mario Valentini - MRV Architects on behalf of
petitioner Kelsi Hall (Hamra Chicago LLC)
Mr. Valentini explains that the request is proposing to construct a new,
approximately 4,000 square foot multi-tenant building with an additional 2,450
square foot restaurant and drive-through on the end cap of the new building. The
existing building on the property will be demolished once the utilities have been
disconnected. Mr. Valentini presents a site plan, a building grading plan showing
the intended landscaping and notes that all trash enclosures would be located in
the back of the building. He states that the new building materials would coincide
with surrounding storefront establishments. A tentative floor plan is presented
and he states that floor plans would be finalized once tenants have been
established. Mr. Valentini provides further information regarding the construction
for the Wendys restaurant and drive thru construction requirements. He also
provides information on the parking and access points. He states that Hamra
Chicago LLC worked out a cross access agreement with Einstein Bagels which
would allow another access point onto Dundee Road. Vehicles could either
access east bound Dundee Road through Einstein’s property or connect to a full
access point to the east and presents drawings for the proposed cross access at
Einstein Bagels.
He states that the existing water service will be disconnected and a new service
is proposed. Portions of the existing sanitary and storm will be abandoned and
new services are proposed. They intend to reuse as much of the existing utilities
as possible. He also states that the photometric plan would exceed what the
VILLAGE OF PALATINE Page 2
Minutes Plan Commission January 18, 2022
Village would normally allow.
Mr. Kolososki asks if the signage would be illuminated?
Mr. Valentini states that the signs would be as per the village ordinance.
Mr. Kolososki asks if there will be mechanical equipment on the roof of the new
building.
Mr. Valentini states that there would be.
Mr. Kolososki asks if there is any way to eliminate some of the parking spots in
lieu of additional landscaping
Mr. Valentini states that final parking would be based on tenant confirmation and
there is no intention at this time to eliminate any of the parking.
Sworn in staff - Mr. Ben Vyverberg
Mr. Vyverberg provides a summary of the proposed project.
STAFF RECOMMENDATION:
RECOMMENDATION:
The proposed building continues the outlot redevelopment along the Park Place
Dundee Road frontage. Panda Express and Sonic are examples of recent
redevelopments, in this area. Drive through uses are common along Rand and
Dundee Roads. The proposed restaurant and drive through comply with the
parking and stacking requirements. Although the existing property is angular,
the location of the drive through and proposed traffic patterns will function within
the surrounding properties and median along Dundee Road. As noted, the cross
access agreement will provide a benefit to the subject and surrounding
properties. The proposed new multi-tenant building conforms the underlying
Planned Development requirements and adheres to the zoning bulk standards.
Therefore, Staff recommends approval of the Planned Development Amendment
and Special Use, pursuant to the following conditions:
1. The Planned Development Amendment and Special Use shall substantially
conform to the site plan and elevations prepared by MRV Architects, dated
12/08/2021 and engineering plans by Northwestern Engineering
Consultants, dated 12/08/21, and business plan, except as such plans may
be changed to conform to Village Codes and Ordinances
2. The signage shall be revised in a manner acceptable to the Director of
Planning and Zoning and in compliance with the Park Place Planned
Development Ordinance requirements.
3. Parking lot lighting shall be revised in a manner acceptable to the Village
VILLAGE OF PALATINE Page 3
Minutes Plan Commission January 18, 2022
Engineer.
4. IDOT and MWRD permits are required.
5. A cross access agreement with the property owner at 987 E. Dundee Road
(Einstein’s), shall be revised and executed in a manner acceptable to the
Village Attorney.
6. The final traffic directional sign plan within the subject property shall be
submitted in a manner acceptable to the Village Engineer and Director of
Planning and Zoning.
7. The Special Use shall be granted to Hamra Chicago LLC.
Commissioner Dwyer made a motion to close the public hearing.
DISCUSSION:
Mr. Bettenhausen made a motion to accept case #19-73 - 2nd by Mr.
Kolososki; Unanimously approved.
Chairman Dwyer summarized that this request has met the standards and
was unanimously approved by a vote of 4-0. This item will tentatively go to
the Village Council on Monday, January 24th, 2022.
Communications:
Mr. Vyverberg states that Village Council did not recommend approval of the
Quentin Road apartments.
There will be no meeting on 2/1/2022
RESULT: RECOMMENDED TO APPROVE [UNANIMOUS]
MOVER: Rodney Bettenhausen, Plan Commissioner
SECONDER: Robert Kolososki, Plan Commissioner
AYES: Dwyer, Williams, Bettenhausen, Kolososki
ABSENT: Noonan, Friedman, Fedota
VILLAGE OF PALATINE Page 4
Minutes Plan Commission January 18, 2022
V. COMMUNICATIONS
VI. ADJOURNMENT
VILLAGE OF PALATINE Page 5
Agenda
VILLAGE OF PALATINE
VILLAGE HALL - COUNCIL CHAMBERS 200 E. WOOD STREET
PALATINE, IL 60067-5339 – (847) 359-9050
http://www.palatine.il.us
PLAN COMMISSION
AGENDA ● JANUARY 18, 2022
Village Hall - Council Chambers Regular Meeting 7:00 PM
I. CALL TO ORDER
II. APPROVAL OF MINUTES
1. Plan Commission - Regular Meeting - Dec 7, 2021 7:00 PM
III. PUBLIC HEARING
IV. CASE STAFF STATEMENTS
1. 1101 E. Dundee Road - Planned Development Amendment to the Park Place
Shopping Center Planned Development to allow for the construction of a new
multi-tenant building; and 2. A Special Use to permit a restaurant, with drive-
through, as a tenant in the new building.
V. COMMUNICATIONS
VI. ADJOURNMENT
VILLAGE OF PALATINE Page 1
2.1
VILLAGE OF PALATINE
VILLAGE HALL - COUNCIL CHAMBERS 200 E. WOOD STREET
PALATINE, IL 60067-5339 – (847) 359-9050
http://www.palatine.il.us
PLAN COMMISSION
MINUTES ● DECEMBER 7, 2021
Village Hall - Council Chambers Regular Meeting 7:00 PM
I. CALL TO ORDER
Attendee Name Title Status Arrived
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
Dennis Dwyer Chairman Present
Patrick Noonan Plan Commissioner Present
Teri Williams Plan Commissioner Present
Eric Friedman Plan Commissioner Present
Rodney Bettenhausen Plan Commissioner Present
Robert Kolososki Plan Commissioner Absent
Stephen Fedota Plan Commissioner Present
II. APPROVAL OF MINUTES
1. Plan Commission - Regular Meeting - Nov 16, 2021 7:00 PM - Accepted as
Amended
RESULT: ACCEPTED AS AMENDED [UNANIMOUS]
MOVER: Patrick Noonan, Plan Commissioner
SECONDER: Rodney Bettenhausen, Plan Commissioner
AYES: Dwyer, Noonan, Williams, Friedman, Bettenhausen
ABSENT: Kolososki, Fedota
VILLAGE OF PALATINE Page 1
Packet Pg. 2
2.1
Minutes Plan Commission December 7, 2021
III. PUBLIC HEARING
IV. CASE STAFF STATEMENTS
1. 874-920 N. Quentin Road - Preliminary Planned Development to allow a 2-story,
40-unit apartment building. - No Recommendation
Chairman Dwyer read the notice of public hearing that was published in the Daily
Herald on November 22nd, 2021 and mailed to the owners of the surrounding
properties.
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
The following petitioner’s exhibits were introduced:
1. Letter & Description of Project Changes
2. Palatine Parking & Traffic Narrative
3. 9-27-21 Combined Drawing
4. Revised Elevation & Floor Plan 11-24-21
5. Initially Revised Rendering 2nd Submission
6. Proposed Unit Mix - Density Analysis
7. Quentin Apartments - Project Description
8. PPD Application
9. Previously Proposed Elevations
10. Previously Proposed - Initial Site Plan
11. Site Plan & Elevation Changes
12. Resident Email Documents 12 thru 36
13. Public Notice
14. Additional Resident Emails not in Packet
15. Updated Petition and Map of households in the immediate neighborhood
opposed to development - submitted to Plan Commission as of 12/07/21.
Sworn in Petitioners: Jake Victor with Northpoint Development and Andy
Dumke of Alliance Development.
Mr. Victor presents the site plan and explains that over the last 6 months
revisions have been made to incorporate the feedback they received from the
neighbors, staff, and the Plan Commission. He provides information on the
revisions and a summary of the concerns that have been addressed, which
includes changes to the parking, removing the entrance on Poplar Street,
reducing the structure from three stories to two stories with a flat roof, instead of
a pitched roof, landscaping improvements and installing an 8-foot fence. The
changes also include removing balconies facing the single family homes and
removing the retaining walls.
Mr. Victor presents the new proposal and 3-D animation. He states it would be a
high-end development and finishes for the units and community room and
provides details regarding the units available in the complex. He states that the
three bedroom option has been reduced significantly to address the concerns
VILLAGE OF PALATINE Page 2
Packet Pg. 3
2.1
Minutes Plan Commission December 7, 2021
from the surrounding neighbors regarding the number of children that this
development could potentially attract. He summarized the reductions and
characteristics of the units in the revised plan. He indicated that the site plan
remains overparked. The plan also removed the trees within the 20-foot setback
and maintained some that are existing, based upon neighbor feedback and
reviewed the animation presentation of the building. Mr. Victor indicated that
traffic was raised as a concern, their plan projects 15 vehicles during the peak
traffic hour. This is a green building, with significant investment in stormwater
controls. Tenant storage and patios would also be included. The density is
comparable to the Clayson development, approved in unincorporated Cook
County, but adjacent to the site. Mr. Victor states that they would consider
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
adding a second entrance from Quentin Road and reducing the number of units
from 40 units to 36 unit, as part of a condition of review. He also notes that this
would create more room between the detention pond and the playground and the
road. He states that the detention pond is a dry basin. Mr. Victor addresses the
concern regarding the 20-foot setback off Quentin Road and states they would
be willing to provide further setback, if necessary. Mr. Victor believes the density
is appropriate for the site and the R-3 Zoning is being met. Their plan also
address tenant storage and a snow removal plan. He noted that not many other
properties on Quentin Road have deceleration lanes. Mr. Victor provides
information on the tax incentive program. He explains that The State of Illinois is
providing a $15 million investment for this site and it would be providing needed
housing for the Palatine work force. He explains that tenants would have to pass
background checks, have stable income, and prove to be good tenants. They
have also secured $1 million from the Federal Home Loan bank of Chicago. He
provides typical income information and the expected rates for the rental units.
Mr. Dumke states that the Illinois State Agency identified Palatine as a
community with a high demand for affordable work force housing. The area is
typical of where apartment complexes like this would be built, based upon their
review of the area.
Mr. Bettenhausen asks about the staff recommendation for a 2nd entrance off
Quentin Road, because the site looks very tight.
Mr. Dumke states it would be closer to Poplar Street with a right in and a right
out. He explains that they would probably have to shrink the building to the 36
units in order to achieve this request which would also adjust the density of the
project.
Mr. Bettenhausen asks if they would consider reducing the capacity of the
building.
Mr. Dumke states the state agency has made considerable accommodations and
feels that any more reductions in units could affect their funding and the
economics of the site.
Mr. Victor adds that they had to compete for the tax credit and have pushed the
State in this process.
Mr. Dumke confirms that almost 50% of the units are one bedroom and notes
that this change also minimizes the density.
STAFF SUMMARY AND RECOMMENDATION:
VILLAGE OF PALATINE Page 3
Packet Pg. 4
2.1
Minutes Plan Commission December 7, 2021
Mr. Vyverberg provides the staff statement and explains the subject property is
2.53 acres and addresses the revised changes. He presents the revised site
plans and confirms that engineering plans were reviewed by the village engineer
and accepted, with some conditions. He also confirms that the infrastructure is
existing and in place around the Subject Property. Stormwater detention is
provided on the north and south sides of the site. He states that revised plans
have not been submitted to the village or reviewed by Staff for any changes to
the number of entrances to the site or any reduction in units. He noted that a
singular full access off Quentin Road is a concern for staff. He confirms the
landscaping changes that have been submitted. Mr. Vyverberg addresses the
proposed parking spaces, Quentin Road site access, and concerns with the
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
singular full access.
He spoke about accessibility, with the plans being amended to include elevator
access to 20% of the units, as required by Code. This would include a 2 nd story
on the common area. The surrounding density and dimensional information is
also reviewed. Staff sees the Clayson development as a different standard, as it
was developed in unincorporated Cook County and annexed into the Village. He
noted concerns about the confluence of the emergency turnaround, two-way
driveway access to the underground parking, and the existing parking lot drive
aisle. He spoke about the landscaping plan changes, including an 8-foot fence,
and the installation of 10-foot evergreen trees along the western side of the
property. The provided parking is 2.53 spaces per unit, where the typical
townhouse development provides between 4 and 4.5 spaces/unit. Staff remains
concerned about the traffic constraints. In response to a Plan Commission
question, Staff noted a carryover density information did not reflect the current
15.81, as it should have.
Mr. Friedman questions the access to information on the Clayson development to
determine bedrooms per acre at that development. Mr. Vyverberg indicates that
states that the information for this property was processed and developed in
unincorporated Cook County, prior to annexation into the village of Palatine in the
early 90’s. The bedroom count and unit information wasn’t included with the
annexation materials that Staff reviewed.
Mr. Dwyer requested that Staff provide the recommendation for the proposal.
Mr. Vyverberg summarized that the Petitioners reduced the overall density and
provided additional landscaping and screening for the west side of the property.
Additionally, the height of the building was lowered to 2-stories and 26 feet. Staff
notes that the Future Land Use and previous approvals for the property
contemplated a multi-family memory care use and is consistent with the
designation for both Greencastle and the Grand. Also, the proposed is denser
than the other multi-family and townhouse uses. As the Clayson apartments
were planned, approved, and constructed in Cook County, Staff views that
circumstance dissimilar from the proposed.
There is also no access to public transportation, park district facilities, or
recreational facilities, within a vicinity of the property. The plan indicates one
VILLAGE OF PALATINE Page 4
Packet Pg. 5
2.1
Minutes Plan Commission December 7, 2021
outdoor 1,200 square foot fenced recreation area on the west side of the
building. This area is located along the entrance drive to the surface parking lot
and further speaks to the constraints of the site plan, as it is straddled by the
drive aisle and parking lot.
Staff also raised questions and concerns about snowplowing and adequate snow
storage. The Petitioner indicates that snow could be hauled off site, which would
have to be further determined to accommodate. The proposed site plan and
property dimensions of the Subject Property do not likely allow for onsite plowing.
Staff also questions the one access point into the site. A deceleration lane
should also be reviewed coming from Quentin Road into the site. As a condition
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
of review, Staff recommends 2 separate access points to accommodate turns
onto Quentin Road. The elimination of the Poplar Street access may have
addressed previous resident and Staff concerns about the access and traffic, but
the single access point raises additional questions and access and turning
movement concerns within the site plan. Such things as deliveries, maintenance,
moving trips will be forced to use the single access point, which is also shared by
the residents. The dual access plan and reduced unit count referenced at
tonight’s meeting, were also not submitted for Staff review.
The interior of the building has a 1,988 square foot common area space on the
first floor of the area between the buildings, for use by the residents of the 40-
units, which the narrative indicates would have a fitness room. The underground
parking area provides approximately 221 square feet of storage areas and 60
square feet noted for bike storage. This does not seem sufficient for the
additional storage needs for 40 units.
While the elimination of the second access to Poplar Street addressed neighbor
and Staff concerns from the initial Petition, the revised site plan and singular
access point on the south side of the property create additional access and
turning movement concerns with the site plan. The site plan could potentially
relieve potential congestion and turning conflicts by providing a second access
onto Quentin Road.
Staff sees the confluence of the access drive to the underground parking garage,
fire department emergency hammerhead turnaround, and the singular drive to
the surface parking lot, as creating unnecessary traffic conflicts. It also further
bespeaks the dimensional limitations of the proposed site and underlying
property acreage. As proposed, Staff believes that the site plan does not
adequately address or comply with the traffic circulation design standards for
Planned Developments.
Ultimately, Staff cannot support the proposed site plan. If the Plan Commission
recommends approval, Staff recommends the following conditions:
1. The Preliminary Planned Development shall substantially conform to the
Engineering Plans prepared by Vierbicher dated 09/27/2021, and the
Architectural Plans prepared by Knothe Bruce Architects dated 09/27/2021 last
VILLAGE OF PALATINE Page 5
Packet Pg. 6
2.1
Minutes Plan Commission December 7, 2021
revised 11/24/2021, except as such plans may be revised to comply with all of
the accessibility requirements for multi-story buildings and residential facilities, as
required within the building codes, and to conform to Village Codes and
Ordinances.
2. A Plat of Consolidation/Subdivision shall be submitted in a manner acceptable to
the Village Engineer and include all necessary easement language, including a
10-foot easement along the Quentin Road frontage. The plat shall reflect that the
property-owner shall be responsible for all utilities on the property including storm
water maintenance.
3. The Final Engineering plans and Engineers of Probable Cost shall be submitted
in a manner acceptable to the Village Engineer.
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
4. The Final Landscape Plan shall be submitted in a manner acceptable to the
Director of Planning and Zoning. The final plantings on the west side of the
property should also include additional types of trees and bushes to present a
more natural appearance to promote the vibrancy and health of the plantings.
This could include the use of understory trees and bushes.
5. An Auto-Turn Exhibit shall be submitted in a manner acceptable to the Fire
Marshal.
6. The required Public Improvement and Planned Development Letters of Credit
and other all fees shall be submitted in a manner acceptable to the Director of
Planning and Zoning and Village Engineer.
7. MWRD, Cook County, and NCCSWC permits are required.
8. In conjunction with the Final Planned Development application process, the
Petitioner shall submit a construction management plan and schedule in a
manner acceptable to the Village of Palatine.
9. If deemed necessary by the Village Engineer and in conjunction with the Final
Planned Development application process, the Petitioner shall submit a Traffic
Impact Study in a manner acceptable to the Village Engineer and Director of
Planning and Zoning. The developer should anticipate possible road
improvements along Quentin Road, including a deceleration lane along and
second access to Quentin Road. The full access point should include two exit
lanes to accommodate left and right turns.
10. A final fencing and screening plan shall be submitted in a manner acceptable to
the Director of Planning and Zoning. The final floorplan and site plan for the
fenced play area shall be submitted in a manner acceptable to the Director of
Planning and Zoning.
11. The Petitioner shall submit a stormwater management and maintenance plan in
a manner acceptable to the Village Engineer.
12. The playground location will be reconsidered to provide additional separation
from the detention basin.
13. The petitioner shall provide a detailed sign plan for the entire site. Information
on the freestanding sign and wayfinding signage for the property shall be
provided in the plan.
VILLAGE OF PALATINE Page 6
Packet Pg. 7
2.1
Minutes Plan Commission December 7, 2021
Chairman Dwyer addresses the petitioner and asks Mr. Dumpke if plan
commission recommends approval, would he abide by the conditions that staff
has noted.
Mr. Dumke states that there is one concern regarding the deceleration lane and
states all other conditions would be accommodated.
Chairman Dwyer opens floor to the audience and explains that they’ve heard
staff recommendations and asks them not to be redundant. He states that all
emails have been read and would like the conversation to not be repetitive.
Mr. Noonan discloses his in-laws are in the audience and states that he can be
unbiased and will vote.
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
Sworn in Mr. Robert Lettecci - 998 N Glenview Court - States he received a
registered letter from the Village of Palatine but post marked in Osh Kosh, WI.
Mr. Vyverberg explained that the letter is drafted by Staff and sent the petitioner
for mailing to the required properties. It is the responsible of the petitioner to send
out. The petitioner resides in Osh Kos, WI.
Mr. Lettecci states his concerns for 94 parking spaces, 56 underground and 38
surface. His opinion is that it is too many vehicles for this area. He also noted
another property on Northwest Highway that is vacant and approximately 2
acres.
Sworn in Julie Jesso - 939 N Franklin Avenue. Ms. Jesso lives behind
development and explains she spent the last 2 weeks meeting with neighbors
and has accumulated over 360 signatures opposing the planned development.
The developer scaled back the proposal, but the main concerns are density,
increased traffic, and quality of life. The meeting with developer didn’t address
the number of units. She urged the plan commission to reject the current
proposal. It is not the right development for the neighborhood, as it is too many
units. The neighborhood never felt or indicated the revisions were adequate to
address the density concerns. The impact to the single-family homes behind the
proposed development cannot be addressed with landscaping or screening, as
the property is too dense and not in line with the other Village densities.
Sworn in Kathy Cortez - 141 S Fremont Street.
Ms. Cortez states she attended the last meeting and would like to address how
affordable housing could be accommodated for this site. She believes that
people don’t understand how bad it is. She spoke to her belief that there is a lot
of noise and biases in the Staff report. She spoke to the proximity of the Clayson
and how it is in the neighborhood and should be considered such. She speaks to
the antiquated zoning practices that do not allow affordable housing in the village
and affordability issues, which disallow the possibility to create affordable
housing in the Village. She requests the commissioners vote to approve the plan.
Mr. Robert Lettecci inquired as to how far away Ms. Cortez lives from the
development.
Sworn in Maria Galo - 117 N Cedar Street.
Has lived in the neighborhood since 1996. She talks about the changes that have
taken place in her neighborhood since she moved there. She states that there
VILLAGE OF PALATINE Page 7
Packet Pg. 8
2.1
Minutes Plan Commission December 7, 2021
have been a variety of housing projects in the neighborhood and the changes
have been positive, with the surrounding development and infrastructure
improvements. She is confident the developer is working to make this a better
place. Urges plan commission to recommend the proposed plan.
Sworn in Nathaniel Groh - 1480 N. Benton Avenue.
Advocates for the development and would like to see it happen. He talks about
his own upbringing by a single mom and believes the affordable housing is a
benefit to those in need. He states this development can give hope to the young
factory workers in Palatine. He would like the Plan Commission to approve the
proposal.
Sworn in Marcus Orofino - 913 N Franklin Ave.
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
He addresses the fair housing in the area. He states they are not against
affordable housing, but is saying no to the dynamics associated to this project.
Noted that the Clayson is a large and sprawling property and not comparable to
the site proposed for this development. He states that the property is not the
right size property for this project. He appreciates the efforts to reduce the size,
but the development is still twice the density.
Sworn in Lori Grainawi - 227 S Vail Avenue - Arlington Heights, IL.
Resident of Arlington Heights - lives less than a mile from an affordable housing
project in Arlington Heights. She used to live in unincorporated Cook County on
Echo Lane, across the street. She is co-president of a housing task force and
worked with the Village of Palatine on the Spruce Village apartment complex,
which is for disabled residents and is also an affordable housing project. She
invites anyone from the Village to visit the site and states it’s a beautiful project.
Village Attorney Brankin interjects that the Commission’s job and focus is upon
land usage and the policy discussions are not relevant not a discussion about
affordable housing, for everyone here and for the record. This is a discussion
about land use.
Chairman Dwyer addresses Ms. Grainawi and states this discussion is for land
use.
Mr. Brankin indicates that it is inappropriate to make accusations about biases.
Staff has prepared a professional report and recommendations, based upon the
land use factors and provided testimony related to the land use factors before
you.
Sworn in Kathleen Bolger - 320 E Tall Trees Lane.
Lives in unincorporated palatine. States that the previous land use for a memory
care facility was not a concern for the neighbors at the time, but the proposed
project is being opposed.
Mr. Vyverberg addresses the previous approved land use and explains it was
approved for the memory care facility, but never implemented.
Mr. Friedman inquired about the conditions related to the access points.
Discussion about the Cook County Highway Department.
Mr. Noonan made a motion to close the public hearing. Mr. Fedota
VILLAGE OF PALATINE Page 8
Packet Pg. 9
2.1
Minutes Plan Commission December 7, 2021
seconded. Motion approved.
DISCUSSION:
Discussion about a 36-unit development, with a 2nd access off Quentin.
Mr. Brankin indicates that the 2nd access and unit count reduction has not been
presented or applied for by the developer or submitted for Staff review. That plan
is not before the Plan Commission, nor has been evaluated by Staff. These
changes would then have to be evaluated through a process.
Discussion about the scope of review.
Mr. Dwyer comments about conditions.
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
Mr. Vyverberg reads condition #9 from the staff recommendations for clarification
that addresses the access points.
Mr. Brankin clarified that the developer is welcome to submit a plan reflective of
those changes, but this is not what was submitted or is before the plan
commission.
Mr. Fedota commented that the unit reduction and 2 nd access point make sense.
Lot density and frontage were previous concerns discussed.
Mr. Friedman spoke to density, land use, and affordable housing and their
respective linkages.
Mr. Bettenhausen clarified that no one denies the need for affordable housing,
but that does not mean that it should be located on any vacant property
available. The resident deserve a safe quality development, including the
neighboring residents.
Mr. Noonan makes a motion to deny.
Mr. Brankin recommended that the motion should be in the affirmative
Mr. Noonan made a motion to approve with the 13 Staff condition. Seconded by
Ms. Williams.
Communication:
LPC Development on Algonquin will go before Village Council on Monday
12/13/21
Meeting anticipated for the first Tuesday in January, 2022
RESULT: NO RECOMMENDATION [3 TO 3]
AYES: Dwyer, Friedman, Fedota
NAYS: Noonan, Williams, Bettenhausen
ABSENT: Kolososki
VILLAGE OF PALATINE Page 9
Packet Pg. 10
2.1
Minutes Plan Commission December 7, 2021
V. COMMUNICATIONS
VI. ADJOURNMENT
Minutes Acceptance: Minutes of Dec 7, 2021 7:00 PM (Approval of Minutes)
VILLAGE OF PALATINE Page 10
Packet Pg. 11
4.1
VILLAGE OF PALATINE
Plan Commission
SCHEDULED 01/18/22 07:00 PM
CASE STAFF STATEMENT (ID # 7308)
1101 E. Dundee Road - Planned Development Amendment to
the Park Place Shopping Center Planned Development to
allow for the construction of a new multi-tenant building; and
2. A Special Use to permit a restaurant, with drive-through, as
a tenant in the new building.
CASE NUMBER: 19-73 - with a 2021 Resubmission
PETITIONER: Chase Grubb - Hamra Chicago LLC
LOCATION: 1101 E. Dundee Road - Park Place Shopping Center (former location of
the Famous Dave's restaurant). This is an outlot parcel in Park Place Shopping Center,
along Rand and Dundee Road corridors. The existing building has been closed and
vacant, since 2011.
PROPOSAL: The Petitioner intends to demolish the existing restaurant and develop a
new multi-tenant building, anchored by a drive-thru Wendy’s restaurant on the eastern
endcap.
SUBJECT ZONING AND LAND USE: Park Place Shopping Center is zoned Planned
Development and was annexed into the Village in 1985. In addition to the Dundee
Road and Rand Road outlots, Park Place has an existing multi-tenant building fronting
on Dundee Road. As the Plan Commission will recall, a new 80,000 square foot U-Haul
storage facility, along the interior in-line building, was approved in 2020 and is working
under an active building permit.
SURROUNDING ZONING AND LAND USES:
North: Planned Development; B2 - general business
South: Planned Development; B-2 - general business
East: Planned Development; B-2 - general business
Page 1
Packet Pg. 12
4.1
Case Staff Statement (ID # 7308)
Meeting of January 18, 2022
West: Planned Development; B-5 - highway business; B-2 - general business
COMPREHENSIVE PLAN:
The Subject Property is located within two of the largest commercial corridors in the
Village and the Future Land Use Guide recommends continued business uses.
BACKGROUND:
The Petitioner intends to demolish the existing vacant former Famous Dave’s restaurant
and construct a new 6,600 square foot multi-tenant building, with a Wendy’s restaurant
and drive through on the eastern side of the building. Therefore, the Petitioner is
seeking approval of the following:
Planned Development Amendment to the Park Place Shopping Center
Planned Development to allow for the construction of a new multi-tenant
building; and
A Special Use for a restaurant, with drive through, as a tenant within the
multi-tenant building
ANALYSIS:
Park Place Shopping Center is approximately 34 acres and was annexed into the
Village in 1985. The first phase of construction was completed in Cook County,
with the remaining development being completed within the Village of Palatine.
In addition to the inline center on the east side of the property, Park Place
includes multiple outlots along Dundee and Rand Roads. The Subject Property is
the location of the former Famous Dave’s restaurant, which has been closed and
vacant, since 2011.
Park Place is unique in that the Planned Development has not only a specific use
list, unto the planned development, but also follows the Cook County C-4 district
and the Village’s B-1 and B-2 use lists. These requirements date to the
annexation agreement and partial development in Cook County.
The Petitioner intends to demolish the existing building and construct a new
multi-tenant building, with a Wendy’s restaurant and drive through to be located
on the eastern side of the building. This outlot is located in between Einstein’s
bagels (west - 987 E. Dundee Road) and Chase Bank (east - 1131 E. Dundee
Page 2
Packet Pg. 13
4.1
Case Staff Statement (ID # 7308)
Meeting of January 18, 2022
Road).
The following summarizes the required and provided parking, drive through and
access within the site and center for the new building:
Square Footage Number of Seats Required
Number of
Parking Spaces
Wendy’s 2,450 50 17
Retail 4,000 N/A 13
Required Number of Parking Spaces 30
Total Number of Parking Spaces 70
o The drive through provides a minimum of 8 stacking spaces and
includes a dedicated escape lane. The escape lane is 11 feet wide,
which is 1 foot narrower than the minimum required 12 feet. Given
that the escape lane runs the length of the drive through and is
separated from the other drive aisles and parking, through curbing,
Staff does not have any specific concerns about the dimensions of
the escape lane.
o The drive through wraps around the south side of the building and
exits into a 2-way drive aisle heading west. Vehicles could then
either access east bound Dundee Road, through the Einstein’s
bagel property, or connect to a full access point to the east on
Dundee Road, south through the property. IDOT and the Village
have been working to install a new stoplight control on Dundee
Road at the Park Place entrance to Walmart and the Sonic/Chase
Bank. This work is anticipated to be complete by the end of March
2022.
o As a proposed condition of review, the Village is requiring a cross-
access agreement with the Einstein’s property to allow full vehicular
turning and movement both entering and exiting the subject
property. Ultimately, this will benefit both properties, particularly
given the IDOT barrier median installation on Dundee Road. The
Petitioners are in agreement with this requirement and have drafted
a proposed agreement for Village review and execution.
Page 3
Packet Pg. 14
4.1
Case Staff Statement (ID # 7308)
Meeting of January 18, 2022
Utilities exist both onsite and within the surrounding area. Per the Utility Plan,
the existing water service will be disconnected and a new service is proposed.
Also, portions of the existing sanitary and storm will be abandoned and new
services are proposed. An IDOT permit will be required to access the sanitary
sewer connection.
Due to the size of the property (1.75-acres), an MWRD permit is required, with
volume control and a detention evaluation requirement. Permeable pavers are
proposed in various sections of the parking lot and areas to assist with
stormwater management within the site.
A new sidewalk is proposed at the northwest corner of the subject property. This
sidewalk will connect to the existing sidewalk parallel to Dundee Road and will be
ADA accessible.
The proposed elevations include both brick and EIFS, with metal capping
components on the elevations and frieze. The façade facing Dundee Road
includes varying building heights along the cornice, as a transition.
Landscaping within the site includes a variety of shade trees, an evergreen tree,
and both deciduous and evergreen shrubs. A total of eight new trees will be
installed in the parking lot and in the Dundee Road right of way. There are also a
variety of perennials and grasses planned for this development.
RECOMMENDATION:
The proposed building continues the outlot redevelopment along the Park Place
Dundee Road frontage. Panda Express and Sonic are examples of recent
redevelopments, in this area. Drive through uses are common along Rand and Dundee
Roads. The proposed restaurant and drive through comply with the parking and
stacking requirements. Although the existing property is angular, the location of the
drive through and proposed traffic patterns will function within the surrounding
properties and median along Dundee Road. As noted, the cross access agreement will
provide a benefit to the subject and surrounding properties. The proposed new multi-
tenant building conforms the underlying Planned Development requirements and
adheres to the zoning bulk standards. Therefore, Staff recommends approval of the
Planned Development Amendment and Special Use, pursuant to the following
conditions:
1. The Planned Development Amendment and Special Use shall substantially
conform to the site plan and elevations prepared by MRV Architects, dated
12/08/2021 and engineering plans by Northwestern Engineering
Page 4
Packet Pg. 15
4.1
Case Staff Statement (ID # 7308)
Meeting of January 18, 2022
Consultants, dated 12/08/21, and business plan, except as such plans may
be changed to conform to Village Codes and Ordinances
2. The signage shall be revised in a manner acceptable to the Director of
Planning and Zoning and in compliance with the Park Place Planned
Development Ordinance requirements.
3. Parking lot lighting shall be revised in a manner acceptable to the Village
Engineer.
4. IDOT and MWRD permits are required.
5. A cross access agreement with the property owner at 987 E. Dundee Road
(Einstein’s), shall be revised and executed in a manner acceptable to the
Village Attorney.
6. The final traffic directional sign plan within the subject property shall be
submitted in a manner acceptable to the Village Engineer and Director of
Planning and Zoning.
7. The Special Use shall be granted to Hamra Chicago LLC.
ATTACHMENTS:
Aerial Map
Planned Development Amendment application
Project Narrative and menu
Special Use application
120821_Wnedy's multi-tenant building -ARCH/ENG plans
Cross Access Easement - Exhibit C
Front and Signature Pages - Palatine - Access Easement Agreement
Plat of Survey
Park Place Planned Development
Public Notice - 1101 E. Dundee Road
Page 5
Packet Pg. 16
4.1.a
Packet Pg. 17
Attachment: Aerial Map (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.b
Packet Pg. 18
Attachment: Planned Development Amendment application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.b
Packet Pg. 19
Attachment: Planned Development Amendment application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.b
Packet Pg. 20
Attachment: Planned Development Amendment application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.b
Packet Pg. 21
Attachment: Planned Development Amendment application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.c
Packet Pg. 22
Attachment: Project Narrative and menu (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.c
Packet Pg. 23
Attachment: Project Narrative and menu (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.c
Packet Pg. 24
Attachment: Project Narrative and menu (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.c
Packet Pg. 25
Attachment: Project Narrative and menu (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.d
Packet Pg. 26
Attachment: Special Use application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.d
Packet Pg. 27
Attachment: Special Use application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.d
Packet Pg. 28
Attachment: Special Use application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.d
Packet Pg. 29
Attachment: Special Use application (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Packet Pg. 30
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Packet Pg. 31
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Packet Pg. 32
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Packet Pg. 33
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Packet Pg. 34
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
PERMEABLE JOINT OPENING SURFACE WATER FLOW PERMEABLE JOINT OPENING SURFACE WATER FLOW PERMEABLE JOINT OPENING SURFACE WATER FLOW
AS DIRECTED BY MANUFACTURER PERMEABLE SETTING BED AGGREGATE AS DIRECTED BY MANUFACTURER PERMEABLE SETTING BED AGGREGATE AS DIRECTED BY MANUFACTURER PERMEABLE SETTING BED AGGREGATE
AS DIRECTED BY MANUFACTURER AS DIRECTED BY MANUFACTURER AS DIRECTED BY MANUFACTURER
PERMEABLE PAVERS PERMEABLE PAVERS PERMEABLE PAVERS
VEGETATED FILTER STRIPS/ VEGETATED FILTER STRIPS/ VEGETATED FILTER STRIPS/
VEGETATED FILTER STRIPS/ VEGETATED FILTER STRIPS/ VEGETATED FILTER STRIPS/
OTHER BMPS (SEE NOTE 10) OTHER BMPS (SEE NOTE 10) OTHER BMPS (SEE NOTE 10)
OTHER BMPS (SEE NOTE 10) OTHER BMPS (SEE NOTE 10) OTHER BMPS (SEE NOTE 10)
10" MIN. VA OBSERVATION WELL, 6"
10" MIN. VA OBSERVATION WELL, 6"
10" MIN. VA OBSERVATION WELL, 6"
GEOTEXTILE FABRIC VB PERFORATED PVC PIPE WITH
LOCKABLE CAP GEOTEXTILE FABRIC VB PERFORATED PVC PIPE WITH
LOCKABLE CAP GEOTEXTILE FABRIC VB PERFORATED PVC PIPE WITH
LOCKABLE CAP
(SIDES ONLY) (SIDES ONLY) (SIDES ONLY)
2'-3.5 OFFSET 2'-3.5 OFFSET 2'-3.5 OFFSET
4" DIAMETER UNDERDRAIN 4" DIAMETER UNDERDRAIN 4" DIAMETER UNDERDRAIN
2" TO 12" 2" TO 12" 2" TO 12"
NATIVE SOIL PERFORATED PIPE, INSTALL IF NATIVE SOIL PERFORATED PIPE, INSTALL IF NATIVE SOIL PERFORATED PIPE, INSTALL IF
PERMEABLE BASE AGGREGATE, INFILTRATION IS LESS THAN 0.50 IN/HR PERMEABLE BASE AGGREGATE, INFILTRATION IS LESS THAN 0.50 IN/HR PERMEABLE BASE AGGREGATE, INFILTRATION IS LESS THAN 0.50 IN/HR
(SEE NOTE 7) (SEE NOTE 7) (SEE NOTE 7)
OPEN-GRADED, CRUSHED, OPEN-GRADED, CRUSHED, OPEN-GRADED, CRUSHED,
(SEE NOTES) (SEE NOTES) (SEE NOTES)
SEASONALLY HIGH SEASONALLY HIGH SEASONALLY HIGH
GROUNDWATER LEVEL GROUNDWATER LEVEL GROUNDWATER LEVEL
BOTTOM OF THE FACILITY: ELEV. ______ BOTTOM OF THE FACILITY: ELEV. ______ BOTTOM OF THE FACILITY: ELEV. ______
SEASONALLY HIGH GROUNDWATER: ELEV. ______ SEASONALLY HIGH GROUNDWATER: ELEV. ______ SEASONALLY HIGH GROUNDWATER: ELEV. ______
SEPARATION: FEET ______ SEPARATION: FEET ______ SEPARATION: FEET ______
VOLUME TYPE SURFACE AREA DEPTH POROSITY STORAGE VOLUME VOLUME PROVIDED VOLUME TYPE SURFACE AREA DEPTH POROSITY STORAGE VOLUME VOLUME PROVIDED VOLUME TYPE SURFACE AREA DEPTH POROSITY STORAGE VOLUME VOLUME PROVIDED
VA : COARSE AGGREGATE (ABOVE INVERT) 0.36 0.50 X 0.36 X V A VA : COARSE AGGREGATE (ABOVE INVERT) 0.36 0.50 X 0.36 X V A VA : COARSE AGGREGATE (ABOVE INVERT) 0.36 0.50 X 0.36 X V A
VB : COARSE AGGREGATE (BELOW INVERT) 0.36 0.36 X V B VB : COARSE AGGREGATE (BELOW INVERT) 0.36 0.36 X V B VB : COARSE AGGREGATE (BELOW INVERT) 0.36 0.36 X V B
TOTAL TOTAL TOTAL
NOTES: NOTES: NOTES:
1. THE PERIMETER OF THE VOLUME CONTROL FACILITY SHALL MAINTAIN THE MINIMUM HORIZONTAL SEPARATION DISTANCE 1. THE PERIMETER OF THE VOLUME CONTROL FACILITY SHALL MAINTAIN THE MINIMUM HORIZONTAL SEPARATION DISTANCE 1. THE PERIMETER OF THE VOLUME CONTROL FACILITY SHALL MAINTAIN THE MINIMUM HORIZONTAL SEPARATION DISTANCE
OF: 10-FEET FROM FOUNDATIONS, UNLESS WATERPROOFED; 20-FEET FROM ROADWAY GRAVEL SHOULDER; AND 100-FEET OF: 10-FEET FROM FOUNDATIONS, UNLESS WATERPROOFED; 20-FEET FROM ROADWAY GRAVEL SHOULDER; AND 100-FEET OF: 10-FEET FROM FOUNDATIONS, UNLESS WATERPROOFED; 20-FEET FROM ROADWAY GRAVEL SHOULDER; AND 100-FEET
FROM POTABLE WATER WELLS, SEPTIC TANKS/FIELDS, OR OTHER UNDERGROUND TANKS. FROM POTABLE WATER WELLS, SEPTIC TANKS/FIELDS, OR OTHER UNDERGROUND TANKS. FROM POTABLE WATER WELLS, SEPTIC TANKS/FIELDS, OR OTHER UNDERGROUND TANKS.
2. SANITARY OR COMBINED SEWERS SHALL NOT BE LOCATED WITHIN THE VOLUME CONTROL FACILITY. SANITARY OR 2. SANITARY OR COMBINED SEWERS SHALL NOT BE LOCATED WITHIN THE VOLUME CONTROL FACILITY. SANITARY OR 2. SANITARY OR COMBINED SEWERS SHALL NOT BE LOCATED WITHIN THE VOLUME CONTROL FACILITY. SANITARY OR
COMBINED SEWERS SHALL NOT BE LOCATED BELOW THE FOOTPRINT OF THE VOLUME CONTROL FACILITY. WHEN LOCAL COMBINED SEWERS SHALL NOT BE LOCATED BELOW THE FOOTPRINT OF THE VOLUME CONTROL FACILITY. WHEN LOCAL COMBINED SEWERS SHALL NOT BE LOCATED BELOW THE FOOTPRINT OF THE VOLUME CONTROL FACILITY. WHEN LOCAL
CONDITIONS PREVENT THE SEWER FROM BEING LOCATED OUTSIDE THE FOOTPRINT OF THE FACILITY THE SEWER SHALL BE CONDITIONS PREVENT THE SEWER FROM BEING LOCATED OUTSIDE THE FOOTPRINT OF THE FACILITY THE SEWER SHALL BE CONDITIONS PREVENT THE SEWER FROM BEING LOCATED OUTSIDE THE FOOTPRINT OF THE FACILITY THE SEWER SHALL BE
CONSTRUCTED TO WATER MAIN QUALITY STANDARDS, OR IT SHALL BE ENCASED WITH A WATER MAIN QUALITY CARRIER CONSTRUCTED TO WATER MAIN QUALITY STANDARDS, OR IT SHALL BE ENCASED WITH A WATER MAIN QUALITY CARRIER CONSTRUCTED TO WATER MAIN QUALITY STANDARDS, OR IT SHALL BE ENCASED WITH A WATER MAIN QUALITY CARRIER
PIPE WITH THE ENDS SEALED. PIPE WITH THE ENDS SEALED. PIPE WITH THE ENDS SEALED.
3. AVOID INSTALLATION ON SLOPES GREATER THAN 3.00 %. AVOID COMPACTING NATIVE SOILS. SCARIFY ANY COMPACTED SOIL. 3. AVOID INSTALLATION ON SLOPES GREATER THAN 3.00 %. AVOID COMPACTING NATIVE SOILS. SCARIFY ANY COMPACTED SOIL. 3. AVOID INSTALLATION ON SLOPES GREATER THAN 3.00 %. AVOID COMPACTING NATIVE SOILS. SCARIFY ANY COMPACTED SOIL.
4. GEOTEXTILE FABRIC SHALL MEET REQUIREMENTS OF IUM MATERIAL SPECIFICATION 592. FOR WOVEN: APPARENT 4. GEOTEXTILE FABRIC SHALL MEET REQUIREMENTS OF IUM MATERIAL SPECIFICATION 592. FOR WOVEN: APPARENT 4. GEOTEXTILE FABRIC SHALL MEET REQUIREMENTS OF IUM MATERIAL SPECIFICATION 592. FOR WOVEN: APPARENT
OPENING SIZE OF 0.50 MM (TABLE 1, CLASS I). FOR NON WOVEN: APPARENT OPENING SIZE OF 0.30 MM (TABLE 2, CLASS II). OPENING SIZE OF 0.50 MM (TABLE 1, CLASS I). FOR NON WOVEN: APPARENT OPENING SIZE OF 0.30 MM (TABLE 2, CLASS II). OPENING SIZE OF 0.50 MM (TABLE 1, CLASS I). FOR NON WOVEN: APPARENT OPENING SIZE OF 0.30 MM (TABLE 2, CLASS II).
5. STONE STORAGE OPTIONS ARE IDOT CA-1, CA-3, CA-7, DISTRICT VULCAN MIX, OR APPROVED ALTERNATE. NO RECYCLED 5. STONE STORAGE OPTIONS ARE IDOT CA-1, CA-3, CA-7, DISTRICT VULCAN MIX, OR APPROVED ALTERNATE. NO RECYCLED 5. STONE STORAGE OPTIONS ARE IDOT CA-1, CA-3, CA-7, DISTRICT VULCAN MIX, OR APPROVED ALTERNATE. NO RECYCLED
MATERIALS. MATERIALS. MATERIALS.
6. MINIMUM DISTANCE OF 2 FEET (3.5 FEET IN COMBINED SEWER AREAS) BETWEEN BOTTOM OF BMP AND SEASONALLY 6. MINIMUM DISTANCE OF 2 FEET (3.5 FEET IN COMBINED SEWER AREAS) BETWEEN BOTTOM OF BMP AND SEASONALLY 6. MINIMUM DISTANCE OF 2 FEET (3.5 FEET IN COMBINED SEWER AREAS) BETWEEN BOTTOM OF BMP AND SEASONALLY
HIGH GROUNDWATER LEVEL. HIGH GROUNDWATER LEVEL. HIGH GROUNDWATER LEVEL.
7. UNDERDRAINS ARE REQUIRED IN TYPICAL CLAYEY SOILS WHERE INFILTRATION RATES ARE LESS THAN 0.5 INCH/HOUR. 7. UNDERDRAINS ARE REQUIRED IN TYPICAL CLAYEY SOILS WHERE INFILTRATION RATES ARE LESS THAN 0.5 INCH/HOUR. 7. UNDERDRAINS ARE REQUIRED IN TYPICAL CLAYEY SOILS WHERE INFILTRATION RATES ARE LESS THAN 0.5 INCH/HOUR.
MAXIMUM OF 1 UNDERDRAIN PER 30 FEET. PROVIDE A SOIL REPORT DOCUMENTING NATIVE INFILTRATION RATE TO MAXIMUM OF 1 UNDERDRAIN PER 30 FEET. PROVIDE A SOIL REPORT DOCUMENTING NATIVE INFILTRATION RATE TO MAXIMUM OF 1 UNDERDRAIN PER 30 FEET. PROVIDE A SOIL REPORT DOCUMENTING NATIVE INFILTRATION RATE TO
FOREGO UNDERDRAINS. FOREGO UNDERDRAINS. FOREGO UNDERDRAINS.
8. MINIMUM UNDERDRAIN BEDDING OF TWO INCHES, MAXIMUM OF 12 INCHES. 8. MINIMUM UNDERDRAIN BEDDING OF TWO INCHES, MAXIMUM OF 12 INCHES. 8. MINIMUM UNDERDRAIN BEDDING OF TWO INCHES, MAXIMUM OF 12 INCHES.
9. ONE OBSERVATION WELL REQUIRED PER 6,000 SQUARE FEET OF SURFACE AREA. 9. ONE OBSERVATION WELL REQUIRED PER 6,000 SQUARE FEET OF SURFACE AREA. 9. ONE OBSERVATION WELL REQUIRED PER 6,000 SQUARE FEET OF SURFACE AREA.
10. FOLLOW THE REQUIRED PRETREATMENT MEASURES LISTED ON THE VOLUME CONTROL PRETREATMENT MEASURES DETAIL. 10. FOLLOW THE REQUIRED PRETREATMENT MEASURES LISTED ON THE VOLUME CONTROL PRETREATMENT MEASURES DETAIL. 10. FOLLOW THE REQUIRED PRETREATMENT MEASURES LISTED ON THE VOLUME CONTROL PRETREATMENT MEASURES DETAIL.
11. MAINTENANCE REQUIREMENTS INCLUDE ANNUAL VACUUMING AND LOW-PRESSURE POWER WASHING OF PAVEMENT 11. MAINTENANCE REQUIREMENTS INCLUDE ANNUAL VACUUMING AND LOW-PRESSURE POWER WASHING OF PAVEMENT 11. MAINTENANCE REQUIREMENTS INCLUDE ANNUAL VACUUMING AND LOW-PRESSURE POWER WASHING OF PAVEMENT
SURFACE. ADJACENT VEGETATED AREAS SHALL BE WELL-MAINTAINED. BARE SPOTS AND ERODED AREAS SHALL BE SURFACE. ADJACENT VEGETATED AREAS SHALL BE WELL-MAINTAINED. BARE SPOTS AND ERODED AREAS SHALL BE SURFACE. ADJACENT VEGETATED AREAS SHALL BE WELL-MAINTAINED. BARE SPOTS AND ERODED AREAS SHALL BE
REPLANTED AND STABILIZED IMMEDIATELY. DO NOT SEALCOAT OR APPLY DE-ICING SAND/GRAVEL/SALT. REPLANTED AND STABILIZED IMMEDIATELY. DO NOT SEALCOAT OR APPLY DE-ICING SAND/GRAVEL/SALT. REPLANTED AND STABILIZED IMMEDIATELY. DO NOT SEALCOAT OR APPLY DE-ICING SAND/GRAVEL/SALT.
APPROPRIATE SIGNAGE REQUIRED FOR FACILITY, REFER TO THE TYPICAL SIGNAGE FOR PERMEABLE PAVEMENT DETAIL. APPROPRIATE SIGNAGE REQUIRED FOR FACILITY, REFER TO THE TYPICAL SIGNAGE FOR PERMEABLE PAVEMENT DETAIL. APPROPRIATE SIGNAGE REQUIRED FOR FACILITY, REFER TO THE TYPICAL SIGNAGE FOR PERMEABLE PAVEMENT DETAIL.
Packet Pg. 35
4.1.e
Packet Pg. 36
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
A. REFERENCED SPECIFICATIONS PIPE MATERIAL PIPE SPECIFICATIONS JOINT SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FOLLOWING, VITRIFIED CLAY PIPE ASTM C-700 ASTM C-425 E. EROSION AND SEDIMENT CONTROL
EXCEPT AS MODIFIED HEREIN OR ON THE PLANS: 1. THE CONTRACTOR SHALL INSTALL THE EROSION AND SEDIMENT CONTROL DEVICES AS SHOWN ON THE
* STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (LATEST EDITION), BY THE REINFORCED CONCRETE SEWER PIPE ASTM C-76 ASTM C-443 APPROVED EROSION AND SEDIMENT CONTROL PLAN.
ILLINOIS DEPARTMENT OF TRANSPORTATION (IDOT SS) FOR ALL IMPROVEMENTS EXCEPT SANITARY
SEWER AND WATER MAIN CONSTRUCTION;
* STANDARD SPECIFICATIONS FOR WATER AND SEWER MAIN CONSTRUCTION IN ILLINOIS, LATEST CAST IRON SOIL PIPE ASTM A-74 ASTM C-564 2. EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE FUNCTIONAL PRIOR TO HYDROLOGIC
EDITION (SSWS) FOR SANITARY SEWER AND WATER MAIN CONSTRUCTION; DISTURBANCE OF THE SITE.
* VILLAGE OF ________________ MUNICIPAL CODE; DUCTILE IRON PIPE ANSI A21.51 ANSI A21.11
* THE METROPOLITAN WATER RECLAMATION DISTRICT OF GREATER CHICAGO (MWRD) WATERSHED 3. ALL DESIGN CRITERIA, SPECIFICATIONS, AND INSTALLATION OF EROSION AND SEDIMENT CONTROL
MANAGEMENT ORDINANCE AND TECHNICAL GUIDANCE MANUAL; POLYVINYL CHLORIDE (PVC) PIPE PRACTICES SHALL BE IN ACCORDANCE WITH THE ILLINOIS URBAN MANUAL.
* IN CASE OF CONFLICT BETWEEN THE APPLICABLE ORDINANCES NOTED, THE MORE STRINGENT SHALL TAKE 6-INCH TO 15-INCH DIAMETER SDR 26 ASTM D-3034 ASTM D-3212
PRECEDENCE AND SHALL CONTROL ALL CONSTRUCTION. 18-INCH TO 27-INCH DIAMETER F/DY=46 ASTM F-679 ASTM D-3212 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE
SITE AT ALL TIMES.
HIGH DENSITY POLYETHYLENE (HDPE) ASTM D-3350 ASTM D-3261,F-2620 (HEAT FUSION)
B. NOTIFICATIONS ASTM D-3035 ASTM D-3212,F-477 (GASKETED) 5. INSPECTIONS AND DOCUMENTATION SHALL BE PERFORMED, AT A MINIMUM:
1. THE MWRD LOCAL SEWER SYSTEMS SECTION FIELD OFFICE MUST BE NOTIFIED AT LEAST TWO (2) WORKING WATER MAIN QUALITY PVC a) UPON COMPLETION OF INITIAL EROSION AND SEDIMENT CONTROL MEASURES, PRIOR TO ANY
DAYS PRIOR TO THE COMMENCEMENT OF ANY WORK (CALL 708-588-4055). 4-INCH TO 36-INCH ASTM D-2241 ASTM D-3139 SOIL DISTURBANCE.
4-INCH TO 12-INCH AWWA C900 ASTM D-3139 b) ONCE EVERY SEVEN (7) CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM EVENT
2. THE VILLAGE OF ________________ ENGINEERING DEPARTMENT AND PUBLIC MUST BE NOTIFIED AT LEAST 24 HOURS 14-INCH TO 48-INCH AWWA C905 ASTM D-3139 WITH GREATER THAN 0.5 INCH OF RAINFALL OR LIQUID EQUIVALENT PRECIPITATION.
PRIOR TO THE START OF CONSTRUCTION AND PRIOR TO EACH PHASE OF WORK. CONTRACTOR SHALL
DETERMINE ITEMS REQUIRING INSPECTION PRIOR TO START OF CONSTRUCTION OR EACH WORK PHASE. 6. SOIL DISTURBANCE SHALL BE CONDUCTED IN SUCH A MANNER AS TO MINIMIZE EROSION.
THE FOLLOWING MATERIALS ARE ALLOWED ON A QUALIFIED BASIS SUBJECT TO DISTRICT REVIEW AND IF STRIPPING, CLEARING, GRADING, OR LANDSCAPING ARE TO BE DONE IN PHASES, THE CO-PERMITTEE
APPROVAL PRIOR TO PERMIT ISSUANCE. A SPECIAL CONDITION WILL BE ADDED TO THE PERMIT WHEN SHALL PLAN FOR APPROPRIATE SOIL EROSION AND SEDIMENT CONTROL MEASURES.
3. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES PRIOR TO BEGINNING CONSTRUCTION FOR THE
EXACT LOCATIONS OF UTILITIES AND FOR THEIR PROTECTION DURING CONSTRUCTION. IF EXISTING THE PIPE MATERIAL BELOW IS USED FOR SEWER CONSTRUCTION OR A CONNECTION IS MADE.
UTILITIES ARE ENCOUNTERED THAT CONFLICT IN LOCATION WITH NEW CONSTRUCTION, IMMEDIATELY 7. A STABILIZED MAT OF CRUSHED STONE MEETING THE STANDARDS OF THE ILLINOIS URBAN MANUAL
NOTIFY THE ENGINEER SO THAT THE CONFLICT CAN BE RESOLVED. CALL J.U.L.I.E. AT 1-800-892-0123. SHALL BE INSTALLED AT ANY POINT WHERE TRAFFIC WILL BE ENTERING OR LEAVING A CONSTRUCTION
PIPE MATERIAL PIPE SPECIFICATIONS JOINT SPECIFICATIONS SITE. SEDIMENT OR SOIL REACHING AN IMPROVED PUBLIC RIGHT-OF-WAY, STREET, ALLEY OR PARKING
POLYPROPYLENE (PP) PIPE AREA SHALL BE REMOVED BY SCRAPING OR STREET CLEANING AS ACCUMULATIONS WARRANT AND
C. GENERAL NOTES TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA.
1. ALL ELEVATIONS SHOWN ON PLANS REFERENCE THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88). 12-INCH TO 24-INCH DOUBLE WALL ASTM F-2736 D-3212, F-477
CONVERSION FACTOR IS _________ FT. 8. CONCRETE WASHOUT FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE ILLINOIS
30-INCH TO 60-INCH TRIPLE WALL ASTM F-2764 D3212, F-477 URBAN MANUAL AND SHALL BE INSTALLED PRIOR TO ANY ON SITE CONSTRUCTION ACTIVITIES INVOLVING
2. MWRD, THE MUNICIPALITY AND THE OWNER OR OWNER'S REPRESENTATIVE SHALL HAVE THE AUTHORITY TO CONCRETE.
INSPECT, APPROVE, AND REJECT THE CONSTRUCTION IMPROVEMENTS.
9. MORTAR WASHOUT FACILITIES SHALL BE CONSTRUCTED IN ADDITION TO CONCRETE WASHOUT
3. THE CONTRACTOR(S) SHALL INDEMNIFY THE OWNER, ENGINEER, MUNICIPALITY, MWRD, AND THEIR AGENTS, FACILITIES FOR ANY BRICK AND MORTAR BUILDING ENVELOPE CONSTRUCTION ACTIVITIES.
ETC., FROM ALL LIABILITY INVOLVED WITH THE CONSTRUCTION, INSTALLATION, OR TESTING OF THIS WORK
ON THE PROJECT. 8. ALL SANITARY SEWER CONSTRUCTION (AND STORM SEWER CONSTRUCTION IN COMBINED SEWER AREAS), 10. TEMPORARY DIVERSIONS SHALL BE CONSTRUCTED AS NECESSARY TO DIRECT ALL RUNOFF FROM
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
REQUIRES STONE BEDDING WITH STONE ¼ ” TO 1” IN SIZE, WITH MINIMUM BEDDING THICKNESS EQUAL HYDROLOGICALLY DISTURBED AREAS TO AN APPROPRIATE SEDIMENT TRAP OR BASIN. VOLUME
4. THE PROPOSED IMPROVEMENTS MUST BE CONSTRUCTED IN ACCORDANCE WITH THE ENGINEERING PLANS TO ¼ THE OUTSIDE DIAMETER OF THE SEWER PIPE, BUT NOT LESS THAN FOUR (4) INCHES NOR MORE CONTROL FACILITIES SHALL NOT BE USED AS TEMPORARY SEDIMENT BASINS.
AS APPROVED BY MWRD AND THE MUNICIPALITY UNLESS CHANGES ARE APPROVED BY MWRD, THE THAN EIGHT (8) INCHES. MATERIAL SHALL BE CA-7, CA-11 OR CA-13 AND SHALL BE EXTENDED AT LEAST 12”
MUNICIPALITY, OR AUTHORIZED AGENT. THE CONSTRUCTION DETAILS, AS PRESENTED ON THE PLANS, MUST ABOVE THE TOP OF THE PIPE WHEN USING PVC. 12. DISTURBED AREAS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR
BE FOLLOWED. PROPER CONSTRUCTION TECHNIQUES MUST BE FOLLOWED ON THE IMPROVEMENTS PERMANENTLY CEASED SHALL BE STABILIZED WITH TEMPORARY OR PERMANENT MEASURES WITHIN
INDICATED ON THE PLANS. 9. NON-SHEAR FLEXIBLE-TYPE COUPLINGS SHALL BE USED IN THE CONNECTION OF SEWER PIPES SEVEN (7) DAYS.
OF DISSIMILAR PIPE MATERIALS.
5. THE LOCATION OF VARIOUS UNDERGROUND UTILITIES WHICH ARE SHOWN ON THE PLANS ARE FOR 13. ALL FLOOD PROTECTION AREAS AND VOLUME CONTROL FACILITIES SHALL, AT A MINIMUM, BE
INFORMATION ONLY AND REPRESENT THE BEST KNOWLEDGE OF THE ENGINEER. VERIFY LOCATIONS AND 10. ALL MANHOLES SHALL BE PROVIDED WITH BOLTED, WATERTIGHT COVERS. SANITARY LIDS SHALL BE PROTECTED WITH A DOUBLE-ROW OF SILT FENCE (OR EQUIVALENT).
ELEVATIONS PRIOR TO BEGINNING THE CONSTRUCTION OPERATIONS. CONSTRUCTED WITH A CONCEALED PICKHOLE AND WATERTIGHT GASKET WITH THE WORD “SANITARY”
CAST INTO THE LID. 14. VOLUME CONTROL FACILITIES SHALL NOT BE CONSTRUCTED UNTIL ALL OF THE CONTRIBUTING
6. ANY EXISTING PAVEMENT, SIDEWALK, DRIVEWAY, ETC., DAMAGED DURING CONSTRUCTION OPERATIONS DRAINAGE AREA HAS BEEN STABILIZED.
AND NOT CALLED FOR TO BE REMOVED SHALL BE REPLACED AT THE EXPENSE OF THE CONTRACTOR. 11. WHEN CONNECTING TO AN EXISTING SEWER MAIN BY MEANS OTHER THAN AN EXISTING WYE, TEE, OR
AN EXISTING MANHOLE, ONE OF THE FOLLOWING METHODS SHALL BE USED: 15. SOIL STOCKPILES SHALL, AT A MINIMUM, BE PROTECTED WITH PERIMETER SEDIMENT CONTROLS.
7. MATERIAL AND COMPACTION TESTING SHALL BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS a) A CIRCULAR SAW-CUT OF SEWER MAIN BY PROPER TOOLS (“SHEWER-TAP” MACHINE OR SIMILAR) SOIL STOCKPILES SHALL NOT BE PLACED IN FLOOD PROTECTION AREAS OR THEIR BUFFERS.
OF THE MUNICIPALITY, MWRD, AND OWNER. AND PROPER INSTALLATION OF HUBWYE SADDLE OR HUB-TEE SADDLE.
b) REMOVE AN ENTIRE SECTION OF PIPE (BREAKING ONLY THE TOP OF ONE BELL) AND REPLACE WITH 16. EARTHEN EMBANKMENT SIDE SLOPES SHALL BE STABILIZED WITH APPROPRIATE EROSION CONTROL
8. THE UNDERGROUND CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS TO NOTIFY ALL A WYE OR TEE BRANCH SECTION. BLANKET.
INSPECTION AGENCIES. c) WITH PIPE CUTTER, NEATLY AND ACCURATELY CUT OUT DESIRED LENGTH OF PIPE FOR INSERTION 17. STORM SEWERS THAT ARE OR WILL BE FUNCTIONING DURING CONSTRUCTION SHALL BE PROTECTED
OF PROPER FITTING, USING “BAND SEAL” OR SIMILAR COUPLINGS TO HOLD IT FIRMLY IN PLACE. BY APPROPRIATE SEDIMENT CONTROL MEASURES.
9. ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS DISTURBED DURING CONSTRUCTION
SHALL BE ADJUSTED TO FINISH GRADE PRIOR TO FINAL INSPECTION. 12. WHENEVER A SANITARY/COMBINED SEWER CROSSES UNDER A WATERMAIN, THE MINIMUM VERTICAL 18. THE CONTRACTOR SHALL EITHER REMOVE OR REPLACE ANY EXISTING DRAIN TILES AND INCORPORATE
DISTANCE FROM THE TOP OF THE SEWER TO THE BOTTOM OF THE WATERMAIN SHALL BE 18 INCHES. THEM INTO THE DRAINAGE PLAN FOR THE DEVELOPMENT. DRAIN TILES CANNOT BE TRIBUTARY TO A
10. RECORD DRAWINGS SHALL BE KEPT BY THE CONTRACTOR AND SUBMITTED TO THE ENGINEER AS SOON AS FURTHERMORE, A MINIMUM HORIZONTAL DISTANCE OF 10 FEET BETWEEN SANITARY/COMBINED SANITARY OR COMBINED SEWER. DRAIN TILES ALLOWED IN COMBINED SEWER AREA FOR
UNDERGROUND IMPROVEMENTS ARE COMPLETED. FINAL PAYMENTS TO THE CONTRACTOR SHALL BE HELD SEWERS AND WATERMAINS SHALL BE MAINTAINED UNLESS: THE SEWER IS LAID IN A SEPARATE GREEN INFRASTRUCTURE PRACTICES.
UNTIL THEY ARE RECEIVED. ANY CHANGES IN LENGTH, LOCATION OR ALIGNMENT SHALL BE SHOWN IN RED. TRENCH, KEEPING A MINIMUM 18” VERTICAL SEPARATION; OR THE SEWER IS LAID IN THE SAME
ALL WYES OR BENDS SHALL BE LOCATED FROM THE DOWNSTREAM MANHOLE. ALL VALVES, B-BOXES, TEES TRENCH WITH THE WATERMAIN LOCATED AT THE OPPOSITE SIDE ON A BENCH OF UNDISTURBED
OR BENDS SHALL BE TIED TO A FIRE HYDRANT. EARTH, KEEPING A MINIMUM 18” VERTICAL SEPARATION. IF EITHER THE VERTICAL OR HORIZONTAL 19. IF DEWATERING SERVICES ARE USED, ADJOINING PROPERTIES AND DISCHARGE LOCATIONS SHALL
DISTANCES DESCRIBED CANNOT BE MAINTAINED, OR THE SEWER CROSSES ABOVE THE WATER MAIN, BE PROTECTED FROM EROSION AND SEDIMENTATION. DEWATERING SYSTEMS SHOULD BE INSPECTED
THE SEWER SHALL BE CONSTRUCTED TO WATER MAIN STANDARDS OR IT SHALL BE ENCASED WITH A DAILY DURING OPERATIONAL PERIODS. THE SITE INSPECTOR MUST BE PRESENT AT THE
D. SANITARY SEWER
WATER MAIN QUALITY CARRIER PIPE WITH THE ENDS SEALED. COMMENCEMENT OF DEWATERING ACTIVITIES.
1. THE CONTRACTOR SHALL TAKE MEASURES TO PREVENT ANY POLLUTED WATER, SUCH AS GROUND AND
SURFACE WATER, FROM ENTERING THE EXISTING SANITARY SEWERS. 13. ALL EXISTING SEPTIC SYSTEMS SHALL BE ABANDONED. ABANDONED TANKS SHALL BE FILLED WITH 20. THE CONTRCTOR SHALL BE RESPONSIBLE FOR TRENCH DEWATERING AND EXCAVATION FOR THE
GRANULAR MATERIAL OR REMOVED. INSTALLATION OF SANITARY SEWERS, STORM SEWERS, WATERMAINS AS WELL AS THEIR SERVICES
2. A WATER-TIGHT PLUG SHALL BE INSTALLED IN THE DOWNSTREAM SEWER PIPE AT THE POINT OF SEWER AND OTHER APPURTENANCES. ANY TRENCH DEWATERING, WHICH CONTAINS SEDIMENT SHALL PASS
CONNECTION PRIOR TO COMMENCING ANY SEWER CONSTRUCTION. THE PLUG SHALL REMAIN IN PLACE 14. ALL SANITARY MANHOLES, (AND STORM MANHOLES IN COMBINED SEWER AREAS), SHALL HAVE A THROUGH A SEDIMENT SETTLING POND OR EQUALLY EFFECTIVE SEDIMENT CONTROL DEVICE.
UNTIL REMOVAL IS AUTHORIZED BY THE MUNICIPALITY AND/OR MWRD AFTER THE SEWERS HAVE BEEN MINIMUM INSIDE DIAMETER OF 48 INCHES, AND SHALL BE CAST IN PLACE OR PRE-CAST REINFORCED ALTERNATIVES MAY INCLUDE DEWATERING INTO A SUMP PIT, FILTER BAG OR EXISTING VEGETATED
TESTED AND ACCEPTED. CONCRETE. UPSLOPE AREA. SEDIMENT LADEN WATERS SHALL NOT BE DISCHARGE TO WATERWAYS, FLOOD
PROTECTION AREAS OR THE COMBINED SEWER SYSTEM.
3. DISCHARGING ANY UNPOLLUTED WATER INTO THE SANITARY SEWER SYSTEM FOR THE PURPOSE OF 15. ALL SANITARY MANHOLES, (AND STORM MANHOLES IN COMBINED SEWER AREAS), SHALL HAVE 21. ALL PERMANENT EROSION CONTROL PRACTICES SHALL BE INITIATED WITHIN SEVEN (7) DAYS
SEWER FLUSHING OF LINES FOR THE DEFLECTION TEST SHALL BE PROHIBITED WITHOUT PRIOR APPROVAL PRECAST “RUBBER BOOTS” THAT CONFORM TO ASTM C-923 FOR ALL PIPE CONNECTIONS. PRECAST FOLLOWING THE COMPLETION OF SOIL DISTURBING ACTIVITIES.
FROM THE MUNICIPALITY OR MWRD. SECTIONS SHALL CONSIST OF MODIFIED GROOVE TONGUE AND RUBBER GASKET TYPE JOINTS.
4. ALL SANITARY SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS 22. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED AND REPAIRED AS NEEDED
16. ALL ABANDONED SANITARY SEWERS SHALL BE PLUGGED AT BOTH ENDS WITH AT LEAST 2 FEET LONG ON A YEAR-ROUND BASIS DURING CONSTRUCTION AND ANY PERIODS OF CONSTRUCTION SHUTDOWN
FOR WATER AND SEWER MAIN CONSTRUCTION IN ILLINOIS (LATEST EDITION). NON-SHRINK CONCRETE OR MORTAR PLUG. UNTIL PERMANENT STABILIZATION IS ACHIEVED.
5. ALL FLOOR DRAINS SHALL DISCHARGE TO THE SANITARY SEWER SYSTEM. 17. EXCEPT FOR FOUNDATION/FOOTING DRAINS PROVIDED TO PROTECT BUILDINGS, OR PERFORATED PIPES 23. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN
ASSOCIATED WITH VOLUME CONTROL FACILITIES, DRAIN TILES/FIELD TILES/UNDERDRAINS/PERFORATED THIRTY (30) DAYS AFTER PERMANENT SITE STABILIZATION.
6. ALL DOWNSPOUTS AND FOOTING DRAINS SHALL DISCHARGE TO THE STORM SEWER SYSTEM. PIPES ARE NOT ALLOWED TO BE CONNECTED TO OR TRIBUTARY TO COMBINED SEWERS, SANITARY
SEWERS, OR STORM SEWERS TRIBUTARY TO COMBINED SEWERS IN COMBINED SEWER AREAS. 24. THE EROSION AND SEDIMENT CONTROL MEASURES SHOWN ON THE PLANS ARE THE MINIMUM
7. ALL SANITARY SEWER PIPE MATERIALS AND JOINTS (AND STORM SEWER PIPE MATERIALS AND JOINTS CONSTRUCTION OF NEW FACILITIES OF THIS TYPE IS PROHIBITED; AND ALL EXISTING DRAIN TILES AND REQUIREMENTS. ADDITIONAL MEASURES MAY BE REQUIRED, AS DIRECTED BY THE ENGINEER,
IN A COMBINED SEWER AREA) SHALL CONFORM TO THE FOLLOWING: PERFORATED PIPES ENCOUNTERED WITHIN THE PROJECT AREA SHALL BE PLUGGED OR REMOVED, AND SITE INSPECTOR, OR MWRD.
SHALL NOT BE CONNECTED TO COMBINED SEWERS, SANITARY SEWERS, OR STORM SEWERS TRIBUTARY
TO COMBINED SEWERS.
18. A BACKFLOW PREVENTER IS REQUIRED FOR ALL DETENTION BASINS TRIBUTARY TO COMBINED SEWERS.
REQUIRED BACKFLOW PREVENTERS SHALL BE INSPECTED AND EXERCISED ANNUALLY BY THE PROPERTY
OWNER TO ENSURE PROPER OPERATION, AND ANY NECESSARY MAINTENANCES SHALL BE PERFORMED TO
ENSURE FUNCTIONALITY. IN THE EVENT OF A SEWER SURCHARGE INTO AN OPEN DETENTION BASIN
TRIBUTARY TO COMBINED SEWERS, THE PERMITTEE SHALL ENSURE THAT CLEAN UP AND WASH OUT OF
SEWAGE TAKES PLACE WITHIN 48 HOURS OF THE STORM EVENT.
Packet Pg. 37
4.1.e
Packet Pg. 38
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.e
20' 0
NORTH
10' 20' 40'
MRV
ARCHITECTS, INC.
Scale: 1 inch = 20 ft.
PROPERTY LINE 5105TOLLVIEWDR S,.UITE197
ROADWAY MEDIAN
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
BUILDING MRV ARCHITECTS, INC. 2019
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
DUNDEE RD. TRAFFIC DIRECTION SERVICE AND THEREFORE ARE PROPERTY
EXISTING TREES TO REMAIN, TYP. EXISTING TREE TO REMAIN OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
EXISTING CONCRETE SIDEWALK EXISTING TREE TO BE
26" Honeylocust 22" Honeylocust 30" Honeylocust REMOVED
TO REMAIN SITE NUMBER:
BASE MDL: SMART 55 - 2.0
NOTE: ASSET TYPE: COMP./FRAN
REMOVALS SHOWN ON SITE DEVELOPMENT CLASSIFICATION: NEW
RESTORE ANY PLAN FOR REFERENCE. OWNER:
DISTURBED RETAINING WALL,
AREAS WITH SOD, TYP. SEE ARCH REMOVE EXISTING PEAR TREE BASE VERSION: 2019
UPGRADE CLASSIFICATION:
30' BUILDING LINE
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
22" Pear NEW BUILD
AC PROJECT YEAR: 2019
FIRE TRUCK CE
ACCESS / SS EXISTING ORNAMENTAL FURNITURE PACKAGE: 2019
OVERHANG, CR TREES AND FOUNDATION
OS DRAWING RELEASE SPRING 2019
SEE ARCH SHARED PLANTINGS TO BE REMOVED,
S TYP.
MONUMENT SIGN
NE
PROPERTY LINE W
1101 E. DUNDEE ROAD
TRAFFIC DIRECTION
PRIVATE
DRIVE
REMOVED EXISTING DEAD
PALATINE, ILLINOIS
TREES, TYP.
8" Dead 4" Dead
W1
PROJECT TYPE: NEW BUILD
W1 W1 W1 SMART 55 - 2.0
B
EXISTING SHRUBS TO REMAIN,
PRUNE AND REMOVE ANY
DEADWOOD
REV. DATE DESCRIPTION
A 1 5.25.21 ZONING COMMENTS
2 12.8.21 ZONING COMMENTS
10" Honeylocust
8" Honeylocust ISSUE DATE: 07.31.19
TRASH ENCLOSURE,
225 W Ohio Street - Suite 400; Chicago, IL 60654
SEE ARCH (T) 312-467-0123 | (F) 312-467-0220 PROJECT NUMBER: 18048
DRAWN BY: AH / CM
CHECKED BY: KG
TRASH ENCLOSURE,
SEE ARCH
SEAL
8" Honeylocust
PROPERTY LINE
EXISTING SHRUBS TO REMAIN EXISTING TREES TO REMAIN, TYP.
10" Honeylocust
8" Honeylocust
REMOVED EXISTING ASH TREE SHEET NAME
1 TREE REMOVAL PLAN
TREE REMOVAL PLAN
8" Ash
SCALE: 1" = 20'-0"
#157-000150
SHEET NUMBER
exp. 8/31/21
Keven Graham FASLA, PLA
L0.0
TERRA Engineering Ltd.
225 W. Ohio Street, Fourth Floor
Chicago, Illinois 60610
ph: 312.467.0123
Packet Pg. 39
4.1.e
DUNDEE ROAD
1 PAB
20' 0
NORTH
10' 20' 40'
MRV
ARCHITECTS, INC.
Scale: 1 inch = 20 ft.
PROPERTY LINE
25 VID 5105TOLLVIEWDR S,.UITE197
RESTORE ANY ROLLINGMEADOWIS,L60008
DISTURBED RETAINING WALL, BUILDING
TEL2:24-318-2140
AREAS WITH SOD, TYP. SEE ARCH 2' MULCH STRIP FOR MRV ARCHITECTS, INC. 2019
CAR OVERHANG
35 SPH ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
30' BUILDING LINE 70 NEF SERVICE AND THEREFORE ARE PROPERTY
AC
70 COZ SHADE TREE OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
FIRE TRUCK CE WITHOUT PERMISSION AND EXPRESS
ACCESS / SS WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
OVERHANG, CR 13 PAV
SEE ARCH OS SHARED
S
MONUMENT SIGN EVERGREEN TREE
NE SITE NUMBER:
PROPERTY LINE W
BASE MDL: SMART 55 - 2.0
32 SPH ASSET TYPE: COMP./FRAN
9 RHA 10 RHA DECIDUOUS SHRUBS
CLASSIFICATION: NEW
17 SPH 13 CAA
7 RKO OWNER:
TRAFFIC DIRECTION
ORNAMENTAL GRASSES
2 ACA 9 CAA BASE VERSION: 2019
PRIVATE
UPGRADE CLASSIFICATION:
LAWN SOD
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
NEW BUILD
DRIVE
PROJECT YEAR: 2019
PERENNIAL / GROUNDCOVER
AREAS FURNITURE PACKAGE: 2019
DRAWING RELEASE SPRING 2019
MULCH, 3" DEPTH
3 RHA
1101 E. DUNDEE ROAD
12' X 12' SIGHT TRIANGLE
15 SPH 10 TAD
1 PAB 10 HYA
2 ULM W1 13 ARM
3 RKO LIGHT FIXTURE
PICK-UP
WINDOW
10 PAV
W1 W1 W1
PICK-UP 37 NEF
PALATINE, ILLINOIS
WINDOW 161 LIS 6 RHA
B 3 RKO
5 CAA
33 HEH
39 HEH
23 LIS MULCH STRIP ALONG CURB
15 CAA 27 HEH FOR VEHICULAR OVERHANG
5 RHA
3 RHA 2 ULM
A
PROJECT TYPE: NEW BUILD
SMART 55 - 2.0
1 PAB 3 RHA
11 ARM
TRASH ENCLOSURE,
SEE ARCH
7 VID
9 PAV
TRASH ENCLOSURE, 3 PIA
SEE ARCH
PROPERTY LINE REV. DATE DESCRIPTION
RESTORE ANY DISTURBED 1 5.25.21 ZONING COMMENTS
AREAS WITH SOD, TYP.
2 12.8.21 ZONING COMMENTS
EXISTING TREES TO REMAIN, TYP.
ISSUE DATE: 07.31.19
225 W Ohio Street - Suite 400; Chicago, IL 60654
(T) 312-467-0123 | (F) 312-467-0220 PROJECT NUMBER: 18048
1 LANDSCAPE PLAN
DRAWN BY: AH / CM
CHECKED BY: KG
SCALE: 1" = 20'-0"
SEAL
SHEET NAME
LANDSCAPE PLAN
#157-000150
SHEET NUMBER
exp. 8/31/21
Keven Graham FASLA, PLA
L1.0
TERRA Engineering Ltd.
225 W. Ohio Street, Fourth Floor
Chicago, Illinois 60610
ph: 312.467.0123
Packet Pg. 40
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2019
ALL DRAWINGS, SPECIFICATIONS, PLANS
WHEN PERENNIAL AREAS ARE CALLED AND CONCEPTS ARE INSTRUMENTS OF
EQUAL EQUAL OUT AS "EQUAL MIX", CONTRACTOR SERVICE AND THEREFORE ARE PROPERTY
SHALL INSTALL PLANTS IN GROUPS OF OF MRV ARCHITECTS, INC. THEY MAY NOT
3-5. BE REUSED, COPIED OR REPRODUCED
PLANT SPACING WITHOUT PERMISSION AND EXPRESS
SEE PLANTING PLAN WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
SITE NUMBER:
3" SHREDDED 3" SHREDDED HARDWOOD
HARDWOOD MULCH EQUAL BASE MDL: SMART 55 - 2.0
3" SHREDDED PLANT SPACING MULCH LAYER. TOP OF
HARDWOOD 1" BELOW ADJACENT SEE PLANT LIST MULCH SHALL BE 1-INCH ASSET TYPE: COMP./FRAN
MULCH PAVEMENT BELOW TOP OF ADJACENT
USE PLANTING PAVEMENT. CLASSIFICATION: NEW
SOIL TO CREATE FINISHED GRADE DO NOT PLACE MULCH UP TO
3X OWNER:
3" TALL DISH X STEM OF PLANT
BASE VERSION: 2019
UPGRADE CLASSIFICATION:
TREE ROOT BALL
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
NEW BUILD
· SET ORIGINAL GROUND LINE OF
ROOTBALL AT FINISH GRADE. UNDISTURBED PLANTING SOIL - SEE SPECIFICATIONS, PROJECT YEAR: 2019
· REMOVE NYLON ROPE. SUBGRADE 18" MIN. DEPTH. INSTALL ROOTBALLS
OVER 9" COMPACTED PLANTING SOIL UNDISTURBED SUBGRADE AMENDED PLANTING SOIL FURNITURE PACKAGE: 2019
· SET ROOT BALL ON 9" OF COMPACTED
UNDISTURBED AMENDED PLANTING SOIL (DENSE HATCH) (DENSER HATCH) SEE SPECIFICATIONS, 18"
DRAWING RELEASE SPRING 2019
SUBGRADE MIN. DEPTH
1 SHADE/ORNAMENTAL TREE PLANTING DETAIL 2 SHRUB PLANTING DETAIL GROUNDCOVER / PERENNIAL PLANTING DETAIL
3 SCALE:
1101 E. DUNDEE ROAD
SCALE: NTS SCALE: NTS NTS
PALATINE, ILLINOIS
PROJECT TYPE: NEW BUILD
SMART 55 - 2.0
REV. DATE DESCRIPTION
1 5.25.21 ZONING COMMENTS
2 12.8.21 ZONING COMMENTS
ISSUE DATE: 07.31.19
225 W Ohio Street - Suite 400; Chicago, IL 60654
(T) 312-467-0123 | (F) 312-467-0220 PROJECT NUMBER: 18048
DRAWN BY: AH / CM
CHECKED BY: KG
SEAL
SHEET NAME
LANDSCAPE DETAILS
#157-000150
SHEET NUMBER
exp. 8/31/21
Keven Graham FASLA, PLA
L2.0
TERRA Engineering Ltd.
225 W. Ohio Street, Fourth Floor
Chicago, Illinois 60610
ph: 312.467.0123
Packet Pg. 41
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
A A
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
A
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
D
PUD AMENDMENT
W
W1 W1 W1
B
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
D A
B
PROJECT TYPE: END CAP
SMART 55 - 2.0
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
PHOTOMETRIC SITE PLAN
1" = 20'-0" 1
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
PHOTMETRIC PLAN
SHEET NUMBER
PH1.1
Packet Pg. 42
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
DUNDEE ROAD SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
PUD AMENDMENT
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
PROJECT TYPE: END CAP
SMART 55 - 2.0
PICK-UP
ER WINDOW
NT
CE
TY
MU
NI
OM
PICK-UP
TC WINDOW
RT
HW
DIRECTIONAL ES
NO
SIGNAGE FRONT & TF
OR
SIDE EM
1/4" = 1'-0" 3 EA
S
EN
REV. DATE DESCRIPTION
IN G 1 06-02-21 SPECIAL USE PERMIT SUBMISSION
PA
RK 2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
E
AC
SP
10
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
ARCHITECTURAL SITE PLAN
& SIGNAGE DETAILS
SHEET NUMBER
MONUMENT SIGN
FRONT & SIDE
1/4" = 1'-0" 2
FIRE TRUCK TURNING STUDY
1" = 20'-0" 1 AS1.1
Packet Pg. 43
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
PUD AMENDMENT
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
PROJECT TYPE: END CAP
SMART 55 - 2.0
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
FIRE TRUCK TURNING STUDY
SHEET NUMBER
FIRE TRUCK TURNING STUDY
1" = 20'-0" 1 AS1.2
Packet Pg. 44
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
SIDEWALK FINISH DETAIL PATIO RAILIING DETAIL SIGN BASE DETAIL 6" BOLLARD DETAIL ASSET TYPE: COMP./FRAN
1/2" = 1'-0" 11 1/2" = 1'-0" 9 1/2" = 1'-0" 6 1/2" = 1'-0" 3 CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
PUD AMENDMENT
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
SAFETY RAILIING DETAIL PAVEMENT MARKER DETAIL
1/2" = 1'-0" 8 1/2" = 1'-0" 2
PROJECT TYPE: END CAP
SMART 55 - 2.0
SIDEWALK RAMP DETAIL
N.T.S. 5
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
SITE DETAILS
SHEET NUMBER
ACCESSIBLE SIGN
10
EXTERIOR POLE LIGHT DETAIL
7 CONCRETE CURB DETAIL
AS2.1
N.T.S. 3/4" = 1'-0"
1" = 1'-0" 1
Packet Pg. 45
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
PUD AMENDMENT
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
MENU BOARD FOUNDATION DETAIL CANOPY PROTECTION BAR PRE-SELL BOARD DETAIL
3/4" = 1'-0" 6 1/2" = 1'-0" 4 3/4" = 1'-0" 2
PROJECT TYPE: END CAP
SMART 55 - 2.0
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
®
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
SINGLE LANE DRIVE-THRU
ORDER STATION DETAILS
SHEET NUMBER
PARTIAL PLAN VIEW CANOPY FOOTING SECTION
5 ORDER STATION CANOPY CANOPY FOOTING DETAIL
1
AS3.1
3/8" = 1'-0" 7 3/4" = 1'-0" 1/2" = 1'-0" 3 1 1/2" = 1'-0"
Packet Pg. 46
4.1.e
MRV
ARCHITECTS, INC.
111'-8" 5105TOLLVIEWDR S,.UITE197
24'-0" 8'-0" 22'-0" 8'-0" 4'-0" 43'-8" 2'-0" ROLLINGMEADOWIS,L60008
2" 4 1/2" 1'-7 1/2" TEL2:24-318-2140
4'-0" 5'-0" 6'-0" 5'-0" 4'-0" 4'-0" 10'-10" 3'-0" 4'-0" 2'-2" 3'-0" 13'-2 1/2" 20'-3 1/2" 3'-0" MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
4'-0"
3'-11"
5'-4 1/2"
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
4'-11 1/2"
CLASSIFICATION: NEW
4 1/2" 5" 5" 14'-2"
OWNER:
4'-10 1/2"
64'-0" 18'-6" 7'-8" 10'-7" 8'-3 1/2"
BASE VERSION: 2021
5"
UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
24'-0" 16'-0"
4'-8 1/2"
3'-6"
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
8'-2 1/2"
DRAWING RELEASE SUMMER 2021
7" 4'-0"
13'-8" 7'-11" 4'-2 1/2" 4'-3" 10'-4" 8'-9 1/2"
4"
1'-1"
PUD AMENDMENT
4" 6"
4'-0"
3'-0"
40'-3" 13'-8"
4'-0"
3'-1"
1101 E. DUNDEE ROAD
3'-9 1/2"
4"
9 1/2"
4" 4" 4" 4" 4"
5'-3"
9'-9 1/2" 5'-7 1/2" 5'-9" 3'-1" 7'-6" 11'-2"
2'-0"
51'-2"
11'-0"
4" 5"
PALATINE, ILLINOIS
SP
6'-7 1/2"
7'-0" 5 1/2" SP
5'-7 1/2" 12'-1" 2'-9"
62'-6 1/2"
4" 5"
5 1/2"
4"
64'-0" 2'-2"
4"
PROJECT TYPE: END CAP
15'-2" SMART 55 - 2.0
5'-8"
3'-0"
4" 10'-4" 3'-8 1/2"
4"
5 1/2" 5"
2'-0"
3'-6 1/2" 3'-4"
4" 3'-6"
3'-11"
40'-0" 2'-4"
7'-3" REV. DATE DESCRIPTION
9'-2" 1 06-02-21 SPECIAL USE PERMIT SUBMISSION
4"
6'-10" 8'-2"
4'-0"
3'-2 1/2" 2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
4"
54'-7 1/2" 9'-4 1/2" 2'-3 1/2"
1'-5" 5"
9'-5 1/2" ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
15'-6" 3'-10" 26'-8" 3'-3"
5"
14'-5"
49'-8" SEAL
11'-2" 13'-2"
2'-0"
SHEET NAME
FLOOR PLAN
10'-0" 13'-4" 3'-4" 13'-4" 5'-4" 3'-4" 1'-4" 10'-8" 3'-4" 1'-6"
65'-6"
SHEET NUMBER
65'-6"
PLAN
Packet Pg. 47
4.1.e
EXTERIOR FINISH SCHEDULE
SF-1
PUW
M-1
M-3
STOREFRONT -"DARK BRONZE"
PICK-UP WINDOW TO MATCH STOREFRONT
PARAPET CAP/ BRAKE METAL - "DARK BRONZE"
EXCEPTIONAL METALS - "BRIGHT RED"
MRV
M-4 EXCEPTIONAL METALS - PAINTED TO MATCH BRICK BELOW ARCHITECTS, INC.
M-5 BRAKE METAL - "CLEAR ANNODIZED"
M-7 EXCEPTIONAL METALS - "CUSTOM DARK GREY"
M-8 EXCEPTIONAL METALS - PAINTED TO MATCH CORNICE 5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
E-2 EIFS - "WENDY'S RED" TEL2:24-318-2140
M-3 E-7 EIFS - "DARK GREY" MRV ARCHITECTS, INC. 2021
M-3 ALL DRAWINGS, SPECIFICATIONS, PLANS
E-8 EIFS - "TAN" AND CONCEPTS ARE INSTRUMENTS OF
E-2 SERVICE AND THEREFORE ARE PROPERTY
BR-1 BL-1 BOLLARD SLEEVE - "YELLOW" OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
M-7 M-7 PEX-1 PAINT - DARK BRONZE (SEE PAINT SCHEDULE) WITHOUT PERMISSION AND EXPRESS
M-4 BR-1 M-4 WRITTEN CONSENT FROM MRV
E-7 E-7 PEX-3 PRE-FINISHED DARK BRONZE SIGN CABINETS (SEE PAINT ARCHITECTS, INC.
SCHEDULE)
PEX-10 PAINT / POWDER COAT- BLACK (SEE PAINT SCHEDULE)
PEX-12 PAINT- DARK GREY (SEE PAINT SCHEDULE) SITE NUMBER: 12983
BR-1 THRU-WALL - INTERSTATE (7 5/8"H x 3 5/8"D x15 5/8"L) BASE MDL: SMART 55 - 2.0
"BRONZESTONE"
BR-2 THRU-WALL - INTERSTATE (7 5/8"H x 3 5/8"D x15 5/8"L) ASSET TYPE: COMP./FRAN
"WALNUT"
CLASSIFICATION: NEW
M-5 M-5
ST-1 CAST STONE SILL- SHOULDICE DESIGNER STONE "824"
WATER TABLE, "CRYSTAL WHITE - LS" OWNER:
PUW
BASE VERSION: 2021
UPGRADE CLASSIFICATION:
M-5
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
E-2
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
BL-1 SF-1 ST-1 BL-1 SF-1 PUW ST-1 E-2
BR-1 M-1 M-1
PUD AMENDMENT
BR-2 BR-2
EAST ELEVATION
3/16" = 1'-0" 1 1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
PROJECT TYPE: END CAP
SMART 55 - 2.0
M-3 M-3 E-8
E-8
M-3 E-2 E-2 M-8
E-8 M-4 M-4
M-8
E-2
M-8 BR-1 BR-1
M-7
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
E-7 E-8
M-5 M-1 M-5 M-5 M-5
ISSUE DATE: 03-19-21
M-5 PROJECT NUMBER: 21074
BR-1
DRAWN BY: EVC
CHECKED BY: MRV
ST-1
SEAL
BR-2
SF-1 SF-1 SF-1 BR-2 SF-1 BR-1 SF-1 BR-2 ST-1
E-2 ST-1 BR-1 BR-2 ST-1 BR-1 SF-1 BR-2
SHEET NAME
EXTERIOR ELEVATIONS
NORTH ELEVATION
3/16" = 1'-0" 2 SHEET NUMBER
A2.1
Packet Pg. 48
4.1.e
EXTERIOR FINISH SCHEDULE
SF-1
PUW
M-1
M-3
STOREFRONT -"DARK BRONZE"
PICK-UP WINDOW TO MATCH STOREFRONT
PARAPET CAP/ BRAKE METAL - "DARK BRONZE"
EXCEPTIONAL METALS - "BRIGHT RED"
MRV
M-4 EXCEPTIONAL METALS - PAINTED TO MATCH BRICK BELOW ARCHITECTS, INC.
M-5 BRAKE METAL - "CLEAR ANNODIZED"
M-7 EXCEPTIONAL METALS - "CUSTOM DARK GREY"
M-8 EXCEPTIONAL METALS - PAINTED TO MATCH CORNICE 5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
E-2 EIFS - "WENDY'S RED" TEL2:24-318-2140
E-7 EIFS - "DARK GREY" MRV ARCHITECTS, INC. 2021
E-8 M-3 ALL DRAWINGS, SPECIFICATIONS, PLANS
E-8 EIFS - "TAN" AND CONCEPTS ARE INSTRUMENTS OF
M-8 SERVICE AND THEREFORE ARE PROPERTY
M-4
E-2 BL-1 BOLLARD SLEEVE - "YELLOW" OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
PEX-1 PAINT - DARK BRONZE (SEE PAINT SCHEDULE) WITHOUT PERMISSION AND EXPRESS
M-4 BR-1 WRITTEN CONSENT FROM MRV
PEX-3 PRE-FINISHED DARK BRONZE SIGN CABINETS (SEE PAINT ARCHITECTS, INC.
SCHEDULE)
E-8 PEX-10 PAINT / POWDER COAT- BLACK (SEE PAINT SCHEDULE)
PEX-12 PAINT- DARK GREY (SEE PAINT SCHEDULE) SITE NUMBER: 12983
BR-1 THRU-WALL - INTERSTATE (7 5/8"H x 3 5/8"D x15 5/8"L) BASE MDL: SMART 55 - 2.0
"BRONZESTONE"
E-8
BR-2 THRU-WALL - INTERSTATE (7 5/8"H x 3 5/8"D x15 5/8"L) ASSET TYPE: COMP./FRAN
BR-1 "WALNUT"
CLASSIFICATION: NEW
ST-1 CAST STONE SILL- SHOULDICE DESIGNER STONE "824"
WATER TABLE, "CRYSTAL WHITE - LS" OWNER:
BR-1
BASE VERSION: 2021
M-5 UPGRADE CLASSIFICATION:
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
BR-2 SF-1 BR-1
PUD AMENDMENT
BR-1 ST-1 BR-1
WEST ELEVATION
3/16" = 1'-0" 1 1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
PROJECT TYPE: END CAP
SMART 55 - 2.0
M-3 M-3 M-3
E-8
E-2 BR-1 E-2 E-2
M-4 M-4
M-8
BR-1 M-4 M-4 BR-1 M-7
E-8 REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
E-7
M-5
BR-1
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
SF-1 CHECKED BY: MRV
BL-1
ST-1 SEAL
BR-2
ST-1
BR-2
BR-1 BR-1
SHEET NAME
EXTERIOR ELEVATIONS
SOUTH ELEVATION
3/16" = 1'-0" 2 SHEET NUMBER
A2.2
Packet Pg. 49
4.1.e
MRV
ARCHITECTS, INC.
5105TOLLVIEWDR S,.UITE197
ROLLINGMEADOWIS,L60008
TEL2:24-318-2140
MRV ARCHITECTS, INC. 2021
ALL DRAWINGS, SPECIFICATIONS, PLANS
AND CONCEPTS ARE INSTRUMENTS OF
SERVICE AND THEREFORE ARE PROPERTY
OF MRV ARCHITECTS, INC. THEY MAY NOT
BE REUSED, COPIED OR REPRODUCED
WITHOUT PERMISSION AND EXPRESS
WRITTEN CONSENT FROM MRV
ARCHITECTS, INC.
SITE NUMBER: 12983
BASE MDL: SMART 55 - 2.0
ASSET TYPE: COMP./FRAN
CLASSIFICATION: NEW
OWNER:
BASE VERSION: 2021
SOUTH ELEVATION (BOH ENTRANCE) UPGRADE CLASSIFICATION:
3/16" = 1'-0" 1
Attachment: 120821_Wnedy's multi-tenant building -ARCH/ENG plans (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
END CAP
PROJECT YEAR: 2021
FURNITURE PACKAGE: 2021
DRAWING RELEASE SUMMER 2021
PUD AMENDMENT
1101 E. DUNDEE ROAD
PALATINE, ILLINOIS
PROJECT TYPE: END CAP
SMART 55 - 2.0
EAST ELEVATION (DRIVE-THRU) WEST ELEVATION
3/16" = 1'-0" 2 3/16" = 1'-0" 3
REV. DATE DESCRIPTION
1 06-02-21 SPECIAL USE PERMIT SUBMISSION
2 12-06-21 SPECIAL USE PERMIT RE-SUBMISSION
ISSUE DATE: 03-19-21
PROJECT NUMBER: 21074
DRAWN BY: EVC
CHECKED BY: MRV
SEAL
SHEET NAME
COLOR ELEVATIONS
SHEET NUMBER
NORTH ELEVATION (MAIN ENTRANCE)
3/16" = 1'-0" 4 CE1.1
Packet Pg. 50
4.1.f
"EXHIBIT C"
DUNDEE ROAD
Attachment: Cross Access Easement - Exhibit C (1101 E. Dundee Road - Wendy's - PDA and SU -
(DON-A-BAR TRACT)
"ACCESS
DRIVE"
(HAMRA TRACT)
(PRIVATE DRIVE)
"CURB CUT AREA"
PICK-UP
WINDOW
PICK-UP
WINDOW
(COMMERCIAL
RETAIL)
(COMMERCIAL
(COMMERCIAL
RETAIL)
RETAIL)
(PUBLIC
LIBRARY)
Packet Pg. 51
4.1.g
Attachment: Front and Signature Pages - Palatine - Access Easement Agreement (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant -
THIS DOCUMENT
WAS PREPARED BY
AND AFTER RECORDING
RETURN TO:
Krista Kron, Esq.
c/o Hamra Enterprises
1855 S. Ingram Mill Road, Suite 100
Springfield, MO 65804
ACCESS EASEMENT AGREEMENT
THIS ACCESS EASEMENT AGREEMENT (this “Agreement”) is made as of the ___ day of
____________, 2021, by and between HAMRA GATEWAY, LLC, a Missouri limited liability company
(“Hamra”), and DON-A-BAR, LLC, an Illinois limited liability company (“Don-A-Bar”).
R E C I T A L S:
This Agreement is entered into upon the basis of the following facts, understandings and intentions of
the parties hereto:
A. Hamra is the owner of the parcel of land situated in Cook County, Illinois, being more particularly
described on Exhibit A attached hereto, and which is identified as the “Hamra Tract” on the site plan
(the “Site Plan”) attached hereto as Exhibit C.
B. Don-A-Bar is the owner of the parcel of land situated immediately adjacent to the Hamra Tract, being
more particularly described on Exhibit B attached hereto, and which is identified as the “Don-A-Bar
Tract” on the Site Plan.
C. Governmental approval has been or will be obtained for a curb cut (the “Curb Cut”) from the Hamra
Tract to the Don-A-Bar Tract, at the location designated on the Site Plan.
D. The Hamra Tract and the Don-A-Bar Tract are sometimes hereinafter collectively referred to as
“Tracts” and individually as a “Tract”. Hamra and Don-A-Bar, and their respective successors and
assigns who become owners of a Tract, are sometimes hereinafter referred to collectively as “Parties”
and individually as a “Party”.
E. The Parties desire to create reciprocal easements for vehicular and pedestrian ingress and egress for
the benefit of their respective Tracts.
NOW, THEREFORE, in consideration of the above Recitals and other good and valuable
consideration, the receipt and sufficiency of which is hereby acknowledged, the Parties agree and covenant as
follows:
Packet Pg. 52
4.1.g
Attachment: Front and Signature Pages - Palatine - Access Easement Agreement (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant -
IN WITNESS WHEREOF, the parties hereto have caused these presents to be executed as of the day
and year first above written.
HAMRA GATEWAY, LLC, a Missouri limited liability company
By:
Name: Michael K. Hamra
Its: President and CEO
DON-A-BAR, LLC, an Illinois limited liability company
By:
Name:
Its:
Packet Pg. 53
4.1.g
Attachment: Front and Signature Pages - Palatine - Access Easement Agreement (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant -
ACKNOWLEDGMENTS
STATE OF_____________ )
) SS.
COUNTY OF __________ )
I, the undersigned, a Notary Public in and for said County, in the State aforesaid, DO HEREBY
CERTIFY that MICHAEL K. HAMRA, the President and CEO of HAMRA GATEWAY, LLC, a Missouri limited
liability company, personally known to me to be the same person whose name is subscribed to the foregoing instrument
as such President and CEO, appeared before me this day in person and acknowledged that he signed and delivered
said instrument as such President and CEO of said limited liability company, as his own free and voluntary act and as
the free and voluntary act of said company, for the uses and purposes therein set forth.
GIVEN under my hand and Notarial Seal this day of _________, 2021.
____________________________________
NOTARY PUBLIC
My Commission Expires:
STATE OF_____________ )
) SS.
COUNTY OF __________ )
I, the undersigned, a Notary Public in and for said County, in the State aforesaid, DO HEREBY
CERTIFY that __________________ , the _________________ of DON-A-BAR, LLC, an Illinois limited liability
company, personally known to me to be the same person whose name is subscribed to the foregoing instrument as
such_______________ , appeared before me this day in person and acknowledged that he/she signed and delivered
said instrument as such ________________ of said limited liability company, as his/her own free and voluntary act
and as the free and voluntary act of said company, for the uses and purposes therein set forth.
GIVEN under my hand and Notarial Seal this day of _________, 2021.
____________________________________
NOTARY PUBLIC
My Commission Expires:
Packet Pg. 54
4.1.h
Packet Pg. 55
Attachment: Plat of Survey (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 56
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 57
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 58
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 59
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 60
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 61
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 62
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 63
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 64
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.i
Packet Pg. 65
Attachment: Park Place Planned Development (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)
4.1.j
Packet Pg. 66
Attachment: Public Notice - 1101 E. Dundee Road (1101 E. Dundee Road - Wendy's - PDA and SU - restaurant - drive through)