Muyni
← Back to Skokie

Appearance Commission

Regular Meeting

Skokie, IL · April 10, 2024

AgendaMinutes

Minutes

Appearance Commission Meeting Minutes Date: April 10, 2024 Appearance Members Present: Chairman Lynk Maryjane Klein Joe Maschek Jay Pathak Thomas DaMario Julie Naumiak Archana Shah Appearance Members Absent: Staff Present: Brian Augustine, Zoning Administrator Nasko Pelinkaj, Building & Zoning Coordinator (I) CALL TO ORDER A quorum being present, Chairman Lynk called the meeting to order. (II) APPROVAL OF MINUTES A motion was made by Commissioner Mascheck to approve the minutes of the previous meeting. The motion was seconded by Commissioner Klein. All members voted aye (III) CASE DESCRIPTIONS Case 2024-009A – 8447 Gross Point Rd Applicant: & Owner: Syed Qasim Request: 1st Floor Addition Discussion and Interested Parties The architect stated a 10x7 sunroom has been built. Staff showed renderings that depict home prior to rehab and showed new addition. Chair asked if that is the extent of the entire project. Staff said the façade and color change as well. 1 Commissioner Maschek asked about materials to be used. The architect said hardy board. Commissioner DaMario asked if addition is visible from the street. The architect said it is set back. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness to approve as Presented. The vote was unanimous. Motion: Naumiak Second: Pathak Absent: None Ayes: 7 Nays: 0 Case 2024-011A – 4999 Old Orchard Center A26 Applicant Laszlo Simovic Owner: Alexios Georges Request: Non-Residential- Façade and Signage Discussion and Interested Parties Commissioner DaMario read Staff comments into the record. Chairman Lynk asked if the proposed was a separate tenant and whether it was different from Maggiano’s. The petitioner replied, yes. Commissioner Maschek asked if the changes include those requested by Old Orchard review. The petitioner replied, yes. Chairman Lynk said that it looked great but questioned whether patrons would mistake the space as being part of Maggiano’s. The petitioner added that the concept currently exists in Evanston on Grove St. Commissioner DaMario asked for the material of the façade. The petitioner replied, black tile. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness. The vote is unanimous. 2 Motion: Maschek Second: Naumiak Absent: None Ayes: 7 Nays: 0 Case 2024-010A – 9023 Niles Center Rd Applicant & Owner: Saleem Ghaffar Request: Residential- 2nd Floor Addition Discussion and Interested Parties Commissioner DaMario read Staff comments into the record. Chairman Lynk asked the petitioner if he was the homeowner. He replied that he is the son of the homeowner. The petitioner added that they are planning an addition to accommodate a growing family. Chairman Lynk asked if it will be all new brick. The petitioner replied that the 1st floor brick would stay and try to match existing. Commissioner Maschek mentioned that there are two different kinds of brick. Chairman Lynk said that the brick cannot be matched. He added that there should be a way to separate the two brick colors. Commissioner Maschek said that stained brick has been approved in the past with common bricks on the side. He asked if the 2nd floor would be bricked or siding. The notes and rendering contradict material usage. The petitioner said that he would need to verify the proposed material for the 2nd floor. Chairman Lynk said that the canopy at the front is too small. Staff added that if a canopy comes into the required front yard by 3’, a Zoning Board of Appeals case would be required. Chairman Lynk said that the canopy should be about 25% wider. Commissioner DaMario said the petitioner must consider whether to match the existing brick or use siding. Chairman Lynk goes to the screen to verify where the new brick meets the existing on the rendering. Commissioner Machek said he preferred hardy board or different cementitious material. Commissioner Macheck said that horizonal siding on the front elevation may look better than brick. Commissioner Shah suggested a band of stone to separate the new and the old. Commissioner Maschek brought up brick spraying as another potential solution. 3 Chairman Lynk stated that brick is ok on the front elevation if it matches and added that it could be stained to match. He added that siding is ok on the side elevations but it should be taken down to the existing brick and that it must be hardy board, not siding. Commissioner Maschek said that there should be a return added to the sides. Commissioner Naumiak does not like the notch on the side. Commissioner DaMario asked the petitioner if he would like to go with the recommendations or come back with a new plan in a month. The petitioner would like to consider the recommendations. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness with the following provisions: the canopy at the front door be widened at least a foot on either side of center; the front elevation be constructed of face brick to match existing brick or stain existing and new brick to match; the side elevations permit the use of a cementitious siding, not vinyl siding; and that the siding match come down to meet the existing brick with no additional brick on side elevations; and a 12’’ return to be incorporated on the front elevation with face brick to the sides. Motion: DaMario Second: Naumiak Absent: Ayes: 7 Nays: 0 (V) ADJOURNMENT Chairman Lynk adjourned the meeting a 7:59PM. 4

Agenda

Meeting Agenda Skokie Appearance Commission Wednesday, April 10, 2024 at 7:30 P.M. Village of Skokie 5127 Oakton Street Skokie, IL 60077 I. Call to Order II. Roll Call III. Approval of Minutes from March 27, 2024 Meeting IV. New Business a. Consideration of a Certificate of Appropriateness for Residential Properties: 2024-009A – 8447 Gross Point Rd. Applicant & Owner: Syed Qasim Request: 1st Floor Addition 2024-010A – 9023 Niles Center Rd. Applicant & Owner: Saleem Ghaffar Request: 2nd Floor Addition b. Consideration of a Certificate of Appropriateness for Non-Residential Properties: 2024-011A – 4999 Old Orchard Center A26. Applicant: Laszlo Simovic Owner: Alexios Georges Request: Non-Residential – Façade & Signage V. Old Business VI. Public Comment (for non-agenda items) VII. Adjourn 618508- Appearance Commission Agenda for April 10, 2024 Appearance Commission Meeting Minutes Date: March 27, 2024 Appearance Members Present: Chairman Lynk Maryjane Klein Joe Maschek Jay Pathak Thomas DaMario Appearance Members Absent: Julie Naumiak Staff Present: Brian Augustine, Zoning Administrator Nasko Pelinkaj, Building & Zoning Coordinator (I) CALL TO ORDER A quorum being present, Chairman Lynk called the meeting to order. (II) APPROVAL OF MINUTES A motion was made by Commissioner DaMario to approve the minutes of the February 28, 2024 meeting. The motion was seconded by Commissioner Pathak. All members voted aye (III) CASE DESCRIPTION Case 2024-005A – 4300 Keeney Ave Applicant: & Owner: Mark & Margaret Lindsay Request: 1st Floor Attached Garage Addition Discussion and Interested Parties DaMario read Staff comments into the record. Chariman Lynk asked if colors would match would existing. The Petitioner responded, yes. Commissioner Maschek admired the midcentury design. Recommendation and Voting 1 A motion was made to grant a Certificate of Appropriateness to approve as Presented. The vote was unanimous. Motion: Maschek Second: Pathak Absent: Naumiak Ayes: 6 Nays: 0 Case 2024-006A – 9543 Lincolnwood Dr Applicant & Owner: Ryan Lezcano Request: 1st and 2nd Floor Addition Discussion and Interested Parties DaMario read Staff comments into the record. Staff asked for verification on where addition will be placed. The architect points out the area near the grill on renderings. Chairman Lynk also asked for clarification on proposed addition location. Commissioner Maschek asked if the gable will peak out. The architect added that that the gable will align with the front and will not be visible from street. Chairman Lynk asked what the material used will be. The architect responded that it will be hardy board or a different type of siding and will match existing in color. Chairman Lynk asked if a calculation on the siding/brick proportions would be required. Staff replied, no. Commissioner Maschek asked if the existing sunroom would be sided with the same cementitious material. The architect said this will be discussed with the homeowner. Commissioner Maschek advised to replace the siding because it is melted. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness. The vote is unanimous. Motion: Pathak Second: Shah Absent: Naumiak Ayes: 6 Nays: 0 2 Case 2024-007A – 9340 Avers Ave Applicant & Owner: Michael Arfa Request: Residential- 1st and 2nd Floor Addition Discussion and Interested Parties Chairman Lynk asked if new materials will blend and if residing. The Petitioner responded, yes. Commissioner Maschek asked for clarification about whether or not the shutters would remain while siding is replaced. He said a wider shutter would look nice. Chairman Lynk reminded the Petitioner to take note of comment regarding fire sprinkler requirements. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness to approve as Presented. The vote is unanimous. Motion: Shah Second: Pathak Absent: Naumiak Ayes: 6 Nays: 0 Case 2024-008A – 8452 Harding Ave Applicant: Walsh Custom Homes Owner: Mark & Terri Bernstein Request: Residential 2nd Floor Addition Discussion and Interested Parties Commissioner DaMario read Staff comments into the record. Staff stated that a slight revision was made and hard copy renderings were brought to the meeting. Chairman Lynk asked if the cantilever is on the back. Chairman DaMario asked if will be less than 2’ in length. The cantilever component is briefly discussed. Chairman Lynk asked Commissioner DaMario if he was ok with the cantilever. Both were ok with the cantilever component. Recommendation and Voting 3 A motion was made to grant a Certificate of Appropriateness to approve as Presented. The vote is unanimous. Motion: Klein Second: Pathak Absent: Naumiak Ayes: 6 Nays: 0 Case 2023-043A – 5425 Touhy Ave Applicant: MJM Architects/Amanda Clark Request: Non Residential- Façade & Signage Discussion and Interested Parties Commissioner DaMario read Staff comments into the record. Chairman Lynk asked whether the changes were part of a nationwide rebranding. Commissioner Maschek said he liked the proposed design better than the current. Chairman Lynk asked for photos of the rest of the mall. He added that the original design of the mall has changed over time, and that he would be ok with the changes if there is precedent for such design. Commissioner DaMario said the lettering on the blue looked smaller than the current. The architect said the lettering will be smaller. Recommendation and Voting A motion was made to grant a Certificate of Appropriateness to approve as Presented. The vote is unanimous. Motion: DaMario Second: Pathak Absent: Naumiak Ayes: 6 Nays: 0 (V) ADJOURNMENT Chairman Lynk adjourned the meeting a 7:49PM. 4 MEMORANDUM Community Development Department To: Michael Lynk, Appearance Commission Chair Appearance Commission Members From: Brian J Augustine, Zoning Administrator/Permit Supervisor Nasko Pelinkaj, Building & Zoning Division Coordinator Jose Acosta, Planning Coordinator Justin Malone, Neighborhood Services Coordinator Date: April 10, 2024 SUBJECT: APPEARANCE COMMISSION STAFF REPORT Staff offers the following comments on the cases scheduled for the April 10, 2024, Appearance Commission meeting: NEW BUSINESS: RESIDENTIAL REQUESTS 2024-009A 8447 Gross Point Rd – Staff has no objections to the proposed addition and façade changes that have already taken place. The proposed addition will need to meet all building code requirements and it need be, will be required to be re-built. The color changes to the siding updated a building that needed some refreshing. 2024-010A 9023 Niles Center Rd – Staff has no objections to the proposed second story addition. The addition is similar in terms of size to an addition at 9031 Niles Center Rd. Staff will verify if all zoning requirements are met, during permit review. If the existing 1st floor brick is not changing, staff would like to see the 2nd floor brick match the existing. If the existing brick is changing, all of the brick should be of a uniform color. NON-RESIDENTIAL REQUESTS 2024-011A 4999 Old Orchard Center A26 – In August, 2022, Maggiano’s received a certificate of appropriateness for their proposed façade and signage changes. The changes included the former Corner Bakery. The approved elevations are in the packet. Staff has no objections to the proposed signage and façade changes. The proposed wall color compliments the approved colors of the Maggiano’s portion of the façade. The signage looks similar to Maggiano’s, but has its own font to stand out on its own. Staff appreciates the landscape planters and lighting on the east elevation to help soften up the façade. Doc 618214 March 27, 2024 Appearance Staff Report 1 8447 GROSS POINT RD, SKOKIE IL LOCATION MAP PROJECT SCOPE MINOR INTERIOR RENOVATION TO EXISTING SINGLE FAMILY RESIDENCE WORK AREA SCHEDULE PROJECT CERTIFICATION FLOOR AREA FIRST FLOOR 1183 SQFT I HEREBY CERTIFY THAT THESE DRAWINGS WERE PREPARED UNDER MY PERSONAL BASEMENT 1101 SQFT SUPERVISION AND TO THE BEST OF MY KNOWLEDGE COMPLY WITH THE LOCAL CODES OF SKOKIE ILLINOIS. TOTAL 2284.00 SQFT ARCHITECT IS NOT RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION. INDEX OF DRAWINGS GENERAL : T100 COVER SHEET ILLINOIS LICENSE NUMBER: 001.020008 LIC. EXP.: APR. 2025 ARCHITECTURAL : PRASHANTH MAHAKALI P.C. ILLINOIS DESIGN FIRM REG. NUMBER: 184.005230 A100 DEMOLITION PLANS A300 PROPOSED PLANS P A400 PROPOSED ELEVATIONS ENERGY CERTIFICATION ELECTRICAL : (50 OIN E100 ELECTRICAL PLANS AND NOTES PLUMBING : I CERTIFY THAT I AM A REGISTERED ENERGY PROFESSIONAL (REP). I ALSO CERTIFY THAT TO P100 PLUMBING DIAGRAMS AND NOTES THE BEST OF MY PROFESSIONAL KNOWLEDGE AND BELIEF THAT THE ATTACHED PLANS FOR 8447 GROSS POINT SKOKIE IL VILLAGE OF OAK PARK, IL / ADOPTED NEED TO COMPLY WITH THE REQUIREMENTS OF THE MUNICIPAL CODE OF SKOKIE .00 T BUILDING CODES 2021 INTERNATIONAL RESIDENTIAL CODE SIGNED: (ARCH.,) DATE:2-8-24 2014 STATE OF ILLINOIS PLUMBING CODE 2020 NATIONAL ELECTRIC CODE ') RD 2021 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL FIRE CODE OS . (12 S 5.0 GR 0') REVISIONS (12 NO. DATE 1 3-25-24 DESCRIPTION REVISIONS 5.0 8'- 1 5 2" 0') 3'- 1 4 DRAWN BY: ----- -----@pmpcarch.com 4" CHECKED BY: JON jon@pmpcarch.com ') DATE ISSUED: .00 0" PROJECT ADDRESS: 2'- 3'- 1 8447 GROSS POINT 9 4" SKOKIE IL 7'- 1 6 (50 2" PERMIT #: N SITE PLAN SCALE: 1/8" = 1'-0" COVER SHEET COPYRIGHT 2025 PRASHANTH MAHAKALI P.C. T100 DEMOLITION NOTES 1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION 2.PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 3.ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE 18'-2" 5'-0" 11'-6" PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH 18'-0" ADJACENT SURFACES. 4.IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED AREAS AT NO COST TO THE OWNER. FP 5.REMOVE EXISTING FLOOR FINISHES AS INDICATED PER PLANS. 6.REMOVE EXISTING DRYWALL AS INDICATED PER PLANS DN 7.REMOVE EXISTING PARTITION WALLS. PROVIDE ANY BATH RM NECESSARY SHORING & BRACING DURING DEMO WORK. 8.REMOVE EXISTING DOORS, FRAMES, AND HARDWARE. 9.REMOVE EXISTING LIGHT FIXTURES AND CEILING FINISHES BEDROOM DOWN TO GYPSUM BOARD AND/OR PLASTER AND LATH CEILING. AS INDICATED PER PLANS REMOVE AND REPLACE EXISTING FLOORING 12'-1" 10.REMOVE ALL BUILT-IN/FREE STANDING EXISTING ROOF OVER DISPLAYUNITS/EQUIPMENT CABINETS, COUNTER TOPS, 16'-0" 14'-4" CARPORT TO REMAIN SHELVING/ ETC. STORE FOR RE-INSTALLATION. COORDINATE WITH OWNER AS INDICATED PER PLANS. LIVING RM 10'-103 4" 11. REMOVE EXISTING PLUMBING FIXTURES AND CAP OFF REMOVE AND REPLACE EXISTING WASTE, WATER PIPING ETC. STORE FOR RE- KITCHEN EXISTING FLOORING INSTALLATION AS INDICATED PER PLANS DW REF CUTTING, PATCHING 10'-9" & REFINISHING 7'-0" SUNROOM 1. WHERE REQUIRED TO CUT INTO EXISTING CONSTRUCTION, REMOVE AND REPLACE RESTORE SURFACES TO THEIR ORIGINAL CONDITION OR TO EXISTING FLOORING THE ADJOINING NEW SURFACE. USE MATERIALS THAT ARE 9'-1112" IDENTICAL TO EXISTING MATERIALS UNLESS OTHERWISE NOTED. IF IDENTICAL MATERIALS ARE NOT AVAILABLE, BEDROOM MATCH WITH REGARD TO VISUAL EFFECT. RESTORE IN A BEDROOM MANNER WHICH WILL ELIMINATE EVIDENCE OF PATCHING 10'-6" AND REFINISHING. 2.DO NOT CUT AND PATCH STRUCTURAL WORK, OR OPERATIONAL- OR SAFETY-RELATED COMPONENTS, THAT WOULD RESULT IN A REDUCTION OF LOAD-CARRYING CAPACITY, LOAD-DEFLECTION RATIO, OR CAPACITY TO PERFORM. 3. TEMPORARILY SEAL DUCT REGISTER BOXES, SUPPLY PLENUMS, FIRST FLOOR PLAN: DEMOLITION 10'-3" 13'-2" RANGE HOOD, BATH EXHAUST FANS, AND LINER BOXES SCALE : 1/4" = 1'-0" DIRECTLY FOLLOWING MECHANICAL ROUGH-IN TO PREVENT O 2' 4' 8' ENTRY OF CONSTRUCTION DUST AND POLLUTANTS INTO DUCT SYSTEM. REMOVE AND REPLACE 4.LEAD BASED PAINT TESTING: THIS HOME WAS CONSTRUCTED EXISTING WALLS AND ROOF IN 1967, AND IS REQUIRED BY FEDERAL LAW TO BE TESTED FOR OVER BASEMENT ENTRY LEAD BASED PAINT. A.TEST ALL INTERIOR AND EXTERIOR PAINTED SURFACES FOR THEPRESENCE OF LEAD. THIS TESTING SHALL BE PERFORMED PRIOR TO ANY REPAIR WORK. TEST RESULTS SHALL BE FURNISHED TO THE OWNER WITHIN 10 CALENDAR DAYS OF THE NOTICE TO PROCEED. 4'-6" 10'-9" B. CERTIFIED TESTER: THE TESTING SHALL BE ACCOMPLISHED AND A REPORT FURNISHED BY A CERTIFIED AND LICENSED INDIVIDUAL. ALL PROCEDURES AND TESTING METHODS SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS. C.LEAD BASED PAINT ABATEMENT, REMOVAL, OR UP ENCAPSULATION: IF ANY SURFACES TEST POSITIVE FOR THE PRESENCE OF LEAD BASED PAINT, THE CONTRACTOR SHALL RECOMMEND THE MOST COST EFFECTIVE METHOD OF ABATING, REMOVING, OR ENCAPSULATING THE HAZARD BATH RM AND A BID FOR THE ACCOMPLISHMENT OF THE REQUIRED 18'-5" REMOVE AND REPLACE WORK. EXISTING FLOORING 12'-0" D.COMPLIANCE RECORDS: SHARE A COPY OF THE STORAGE COMPLIANCE RECORDS REQUIRED FOR REMODELERS UNDER 13'-6" WASHER DRYER THE REGULATION (SUCH AS THE CHECKLIST OF FOLLOWED PRACTICES) WITH HOME OWNERS WITHIN 30 DAYS OF LDRY RM COMPLETION OF THE WORK. 9'-7" F-1 5. ASBESTOS ABATEMENT: IF ASBESTOS-CONTAINING MATERIAL IS DISTURBED, THEN MOVE, REMOVE, ENCAPSULATE OR EXISTING REMOVE AND REPLACE REVISIONS EXISTING FLOORING DISPOSE OF ACCORDING TO ALL LOCAL, STATE AND FEDERAL FURNACE NO. DATE DESCRIPTION LAWS AND REGULATIONS. TO REMAIN HWH MECH. RM. 1 3-25-24 REVISIONS ELEC. PANEL UTILITIES 1.EXISTING UNDERGROUND UTILITIES SHOULD BE LOCATED BY THE CONTRACTOR PRIOR TO BEGINNING 6'-4" 8'-10" DEMOLITION OR CONSTRUCTION. 18'-314" REMOVE AND REPLACE EXISTING DAMAGED DRYWALL DRAWN BY: ----- -----@pmpcarch.com 7'-5" 6" CONC. SLAB JON jon@pmpcarch.com CHECKED BY: SITE WORK FAMILY RM 11'-9" DATE ISSUED: PROJECT ADDRESS: 1.GENERAL CONTRACTOR SHOULD FIELD VERIFY ALL DIMENSIONS AND GRADING CONDITIONS AND SHOULD INFORM ARCHITECT OF FIELD CONDITIONS WHICH REQUIRE MODIFICATIONS TO THE DRAWINGS. 10'-11" 23'-0" G OSS POINT S O IE IL PHASE LEGEND PERMIT #: INDICATES EXISTING CONDITION TO REMAIN UP BASEMENT PLAN: DEMOLITION FD SCALE : 1/4" = 1'-0" O 2' 4' 8' INDICATES EXISTING CONDITION TO BE REMOVED REMOVE AND REPLACE EXISTING/ DEMO PLANS EXISTING WALLS AND ROOF OVER BASEMENT ENTRY GRAPHIC SCALE 0' 2' COPYRIGHT 2025 PRASHANTH MAHAKALI P.C. 4' 8' A100 SECOND FLOOR PLAN: EXISTING 1 WINDOW SCHEDULE CEILING NEW 24" X 24" X 12" NEW PLUMBING TYPE NO. WIDTH HEIGHT SILL HEIGHT LIGHT VENT QTY. CONC. FOOTING UNDER FIXTURES, TILE WALLS NEW POST AND FLOORING FIRST FLOOR DOUBLE HUNG 1 2'-6" 4'-0" 2'-0" 10.00 5.00 1 18'-2" 5'-0" 11'-6" 2'-6" 7'-9" 7'-9" CASEMENT 2 2'-6" 3'-6" 2'-0" 8.75 4.38 12 NOTES : - CONFIRM ALL DOOR AND WINDOW SELECTIONS WITH OWNER PRIOR TO ORDER FP - VERIFY ALL WINDOW AND DOOR SIZES ON SITE BEFORE ORDERING - ALL REPLACEMENT WINDOWS TO HAVE MIN 'U' RATING OF .034 AND CONFORM TO ENERGY CONSERVATION DN CODE OF CITY OF CHICAGO NEW 6 X 6 POST PRESSURE TREATED BATH RM 18'-0" 1. ALL WINDOWS USED FOR LIGHT AND VENT CALCULATIONS IN THIS SCHEDULE ARE SET IN WALLS WHICH VENT ARE A MINIMUM OF 3'-0" FROM THE LOTLINE. (UNLESS PRE-EXISTING) 2. DOORS REQUIRED AS EXITS ARE SIZED AS SHOWN ON THE FLOOR PLAN AS PER 10(13.160.220) ARE SOLID FLOOR EXISTING 2 X 10 CORE DOORS IN 1 HR. WALLS. EXIST DOORS ARE KEYLESS. BEDROOM 12'-1" RAFTERS @ 16" 0.C. NEW FLOORING COMBUSTION AIR OPENING DETAIL 16'-0" 14'-4" EXISTING ROOF OVER NEW APPLIANCES, CABINETS, AND FLOORING SMOKE / CO CARPORT TO REMAIN LIVING RM DETECTOR TO REMAIN SMOKE / CO WALL LEGEND TYP. 1 HR ASSEMBLY NOTE: DETECTOR EACH OPENING SHALL HAVE A MINIMUM KITCHEN NEW FLOORING SMOKE / CO NEW SIDING OVER BUILDING PAPER 34" OVEREXT. PLYWOOD NEW FASCIA AND GUTTERS DETECTOR 3 FREE AREA OF NOT LESS THAN ²1 IN /1000 SMOKE / CO OVER 2 X 4 WD STUDS @ 16" OVER 4" EXT. PLYWOOD OVER VINYL BTU/HR OF THE TOTAL INPUT RATING OF DETECTOR SIDING TOP PLATE ALL FUEL BURNING EQUIPMENT IN THE CONFINED SPACE, BUT NOT LESS THAN 100 EXISTING (3) 2 X 12 TO REMAIN NEW SIDING OVER BUILDING PAPER 34" OVER EX.T PLYWOOD IN². THE MINIMUM DIMENSION OF AIR OVER 2 X 4 WD STUDS @ 16" O.C AND R-19 INSULATION IN OPENINGS SHALL BE NOT LESS THAN 3 IN NEW 6 X 6 POST REF BETWEEN STUDS AND VAPOR BARRIER OVER58"AND GYP. (8CM) DW PRESSURE TREATED DRYWALL FINISH. TAPE & PAINT VINYL SIDING AT EACH SIDE 2'-6" 7'-9" 7'-9" SMOKE / CO DETECTOR (CLASS 1 FINISH) 10'-9" SMOKE / CO SMOKE / CO 3 DETECTOR 4" PLYWOOD 1 LAYER ON EACH DETECTOR SIDE SCREW ATTACH NEW 24" X 24" X 12" 2 SUNROOM CONC. FOOTING UNDER 7'-0" NEW POST 2 X 4 WOOD STUDS KITCHEN HOOD TO BE 100CFM 2 NEW FLOORING NEW 5' SLIDING NEW FLOORING 1 PATIO DOOR NEW FLOORING 9'-1112" A300 SIMPSON BEDROOM BEDROOM STRONG TIE 6x6 TRTD. NEW FOOTINGS POST BASE COLUMN UNDER EXISTING CBSQ66 HDG SUNROOM 10'-6" PRESSURE TREATED FOR 6X6 POST BOTTOM PLATE OR EQUAL 1 1/4"X6 1 FINISH GROUND DECKING 2X6 @ SIMPSON LEVEL STRONG TIE 16"O.C. POST BASE UNDISTURBED NOTE: USE A NEW 2 X 6 CBSQ66 HDG FOR 6X6 POST SOIL SONOTUBE 10'-3" ROOF 13'-2" TO FORM PEDESTAL RAFTERS OR EQUAL 4 - #5 REBAR MIN. CAST -IN-PLACE NEW WOOD DECK 12" DIAMETER VERTICAL CONCRETE PEDESTAL #3 - REBAR 4 - #5 REBAR TIES 18" O.C. NEW RUBBER ROOF MEMBRANE OVER NEW EXTERIOR WALL VERTICAL 2'-0" 3 BUILDING PAPER OVER NEW 4" CDX PLYWOOD WITH NEW ROOF CAST-IN-PLACE SHEATHING OVER 2 X 6 RAFTERS @ 16" O.C CONCRETE 2 3'-33 4" #3 - REBAR FOOTING 3 - #5 REBAR FIRST FLOOR PLAN: PROPOSED A300 TIES 18" O.C. 1'-0" @ 8" O.C. SCALE : 1/4" = 1'-0" EACH DIRECTION O 2' 4' 8' 3" CLEAR 2'-0" 6" 1'-0" 6" CAST -IN-PLACE 2'-0" 12" DIAMETER CONCRETE PEDESTAL NEW PLUMBING 1 FOUNDATION/FOOTING DETAIL FIXTURES, TILE WALLS A-300 SCALE: NTS AND FLOORING 4'-6" 10'-9" NEW RUBBER ROOF MEMBRANE OVER 3 BUILDING PAPER OVER NEW 4" CDX SIMPSON TIES PLYWOOD SHEATHING OVER 2 X 8 JOIST HANGERS OR EQUAL UP RAFTERS @ 16" O.C NEW R-38 INSULATION SMOKE / CO DETECTOR BATH RM STORAGE 18'-5" NOT TO BE USED SIMPSON TIES AS BEDROOM EXISTING FURNACE 12'-0" NEW RUBBER ROOF MEMBRANE OVER JOIST HANGERS 3 OR EQUAL TO REMAIN REVISIONS 13'-6" BUILDING PAPER OVER NEW 4" CDX NEW 2 X 6 LOUVER WASHER DRYER PLYWOOD SHEATHING OVER 2 X 6 NEW GUTTER LEDGER BEAM RAFTERS @ 16" O.C DOOR FOR NO. DATE DESCRIPTION AND FASCIA TO MATCH WITH21"Ø LAG LDRY RM SMOKE / CO COMBUSTION AIR FOR HWH AND FURNACE NEW FLOORING 9'-7" DETECTOR 1 3-25-24 BOLTS F-1 REVISIONS FD FD SMOKE / CO 6'-4" 8'-10" NEW FLOORING DETECTOR NEW 2 X 6 LEDGER BEAM MECH. RM. HWH WITH21"Ø LAG BOLTS NEW GUTTER ELEC. PANEL NEW SIDING OVER BUILDING PAPER 34" OVER AND FASCIA TO MATCH ALL DAMAGED DRYWALL TO BE REMOVED AND REPLACED EX.T PLYWOOD OVER 2 X 4 WD STUDS @ 16" O.C AND R-19 INSULATION IN BETWEEN STUDS NEW VINYL FLOORING DRAWN BY: ----- -----@pmpcarch.com AND VAPOR BARRIER OVER 58 AND " GYP. OVER CONC. SLAB CHECKED BY: JON jon@pmpcarch.com DRYWALL FINISH. TAPE & PAINT EXISTING FURNACE AND HOT WATER EXISTING DATE ISSUED: 18'-314" EXISTING 6" SLAB CONNECTED TO EXISTING CHIMNEY #5 (T&B) DOWELED 6" INTO 6" CONC. SLAB THE EXISTING FOUNDATION NEW FLOORING PROJECT ADDRESS: ON GRADE W/EPOXY GROUT AND EXTENDED 2'-0" INTO NEW GRADE BEAM STEP GRADE BEAM SMOKE / CO DOWN TO BOTTOM DETECTOR +0'-0" GRADE LEVEL VINYL SIDING OVER BUILDING PAPER OVER 3 4" EXT. PLYWOOD OVER 2 X 4 WD STUDS @ OF EXISTING FOOTING ROSS PO N 16" OVER34" EXT. PLYWOOD OVER VINYL 1 FAMILY RM 11'-9" SIDING A300 S O E L NEW21" Ø X 6" EXPANSION NEW 1'-0" X 3'-6" GRADE BEAM 3'-6" MIN. ANCHOR @ 3'-0" O.C. PRESSURE TREATED W/2-#5 CONT. T&B 23'-0" EMBEDDED 6" INTO NEW BOTTOM PLATE (BOTTOM OF GRADE BEAM TO BE MIN. 3'-6" BELOW GRADE #5 (T&B) DOWELED 6" INTO GRADE BEAM THE EXISTING FOUNDATION W/EPOXY GROUT AND EXTENDED PERMIT #: +0'-0" GRADE LEVEL 2'-0" INTO NEW GRADE BEAM 8" CONC. PIER NEW21" Ø X 6" EXPANSION 2-#5 ANCHOR @ 3'-0" O.C. 42" BELOW GRADE EMBEDDED 6" INTO EXISTING T&B FOUNDATION WALL PROPOSED PLANS UP AND SCHEDULES 1'-0" 6X6 COLUMN FD EXISTING FOUNDATION WALL TO REMAIN BASEMENT PLAN: PROPOSED SCALE : 1/4" = 1'-0" COVERED BASEMENT A300 O 2' 4' 8' STAIRS TYP. WALL SECTION @ SUNROOM 1 NTS 2 TYP. WALL SECTION NTS COPYRIGHT 2025 PRASHANTH MAHAKALI P.C. NEW RUBBER ROOF MEMBRANE OVER 3 BUILDING PAPER OVER NEW 4" CDX EXISTING ROOF OVER PLYWOOD SHEATHING OVER 2 X 6 CARPORT TO REMAIN RAFTERS @ 16" O.C NEW FASCIA AND GUTTERS EXISTING 2 X 10 RAFTERS @ 16" 0.C. TO REMAIN EXISTING 2 1 NEW SIDING OVER BUILDING BLG. PAPER OVER34" EXT. PLYWOOD OVER 2 X 4 WD NEW 6 X 6 POST STUDS @ 16" OVER 3 4" EXT. PRESSURE TREATED PLYWOOD OVER VINYL SIDING NEW 24" X 24" X 12" 3'-6" NEW 24" X 24" X 12" 3'-6" NEW SIDING OVER BUILDING 3 CONC. FOOTING UNDER CONC. FOOTING UNDER PAPER OVER 4" EX.T PLYWOOD NEW POST NEW POST OVER 2 X 4 WD STUDS @ 16" O.C SEE DETAIL 1 SHEETA300 SEE DETAIL 1 SHEETA300 AND R-19 INSULATION IN BETWEEN STUDS AND VAPOR BARRIER OVER AND58" GYP. DRYWALL FINISH. TAPE & PAINT EAST ELEVATION: PROPOSED SCALE : 1/4" = 1'-0" O 2' 4' 8' NEW RUBBER ROOF MEMBRANE OVER BUILDING PAPER OVER NEW3 NEW RUBBER ROOF MEMBRANE OVER 4" 3 EXISTING ROOF OVER CDX PLYWOOD SHEATHING BUILDING PAPER OVER NEW 4" CDX CARPORT TO REMAIN OVER 2 X 8 RAFTERS @ 16" O.C PLYWOOD SHEATHING OVER 2 X 6 NEW R-38 INSULATION RAFTERS @ 16" O.C T/O BUILDING 14' - 0" MEAN HEIGHT 11' - 6" NEW FASCIA AND GUTTERS ATTIC 8' - 10" EXISTING 2 X 10 RAFTERS @ 16" 0.C. TO REMAIN NEW SIDING OVER BUILDING EXISTING BLDG. TO REMAIN 8'-0" FIRST FLOOR 0' - 10" 10" GRADE 0' - 0" NEW SIDING OVER BUILDING 3'-6" NEW 6 X 6 POST NEW SIDING OVER BUILDING PAPER OVER34" EXT. NEW 24" X 24" X 12" PRESSURE TREATED 3 PLYWOOD OVER 2 X 4 WD CONC. FOOTING UNDER PAPER OVER 4" EX.T PLYWOOD NEW SLIDING DOOR 3 OVER 2 X 4 WD STUDS @ 16" O.C STUDS @ 16" OVER 4" EXT. NEW POST AND R-19 INSULATION IN BETWEEN PLYWOOD OVER VINYL SEE DETAIL 1 SHEETA300 STUDS AND VAPOR BARRIER OVER SIDING AND58" GYP. DRYWALL FINISH. TAPE SOUTH ELEVATION: PROPOSED & PAINT SCALE : 1/4" = 1'-0" REVISIONS O 2' 4' 8' NO. DATE DESCRIPTION 1 3-25-24 REVISIONS DRAWN BY: ----- -----@pmpcarch.com CHECKED BY: JON jon@pmpcarch.com EXISTING 2 X 10 RAFTERS @ 16" 0.C. EXISTING ROOF OVER DATE ISSUED: TO REMAIN CARPORT TO REMAIN PROJECT ADDRESS: T/O BUILDING 14' - 0" 44 OSS OINT MEAN HEIGHT S O IE IL 11' - 6" ATTIC 8' - 10" NEW FASCIA AND GUTTERS PERMIT #: NEW 6 X 6 POST PRESSURE TREATED EXISTING EXISTING BLG. BLG. ELEVATIONS FIRST FLOOR 0' - 10" GRADE 0' - 0" COPYRIGHT 2025 PRASHANTH MAHAKALI P.C. NORTH ELEVATION: PROPOSED SCALE : 1/4" = 1'-0" O 2' 4' 8' NEW 24" X 24" X 12" CONC. FOOTING UNDER NEW POST SEE DETAIL 1 SHEETA300 3'-6" A400 with new detached garage ROOF RIDGE EL 24'-9" 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 2TH FLOOR EL 10'-8" ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM 1ST FLOOR PROFESSIONAL DESIGN FIRM # 184.007945-0001 EL 0'-0" BASEMENT EL -8'-4" V.I.F. 3 4 ROOF RIDGE EL 24'-9" DATE NO. REMARKS 2ND FLOOR EL 10'-8" 1ST FLOOR EL 0'-0" REVISIONS SHEET TITLE PROPOSED ELEVATIONS BASEMENT EL -8'-11" V.I.F. PHASE: SCALE: 3 4 DATE: SHEET NUMBER A3 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM PROFESSIONAL DESIGN FIRM # 184.007945-0001 DATE NO. REMARKS REVISIONS SHEET TITLE PROPOSED FLOOR PLANS AND NOTES 2 PHASE: A3 SCALE: DATE: N -1 N 1 N 2 SHEET NUMBER A1 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM PROFESSIONAL DESIGN FIRM # 184.007945-0001 DATE NO. REMARKS REVISIONS SHEET TITLE PROPOSED ROOF PLAN, SCHEDULES AND NOTES PHASE: N 1 SCALE: DATE: SHEET NUMBER A2 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM PROFESSIONAL DESIGN FIRM # 184.007945-0001 DATE NO. REMARKS REVISIONS SHEET TITLE GARAGE PHASE: SCALE: DATE: SHEET NUMBER A6 NEW ADDITION OF 2ND FLOOR AND GARAGE TO EXISTING DETACHED HOUSE NEW CONSTRUCTION - SINGLE FAMILY RESIDENCE SINGLE FAMILY RESIDENCE 9023 NILES CENTER RD, SKOKIE, IL 60076 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM PROFESSIONAL DESIGN FIRM # 184.007945-0001 COVER SHEET, GENERAL NOTES, CODE MATRIX AND SITE PLAN MECHANICAL FLOOR PLANS AND SCHEDULES MECHANICAL DIAGRAMS AND NOTES DEMOLITION PLANS AND NOTES ELECTRICAL PLANS, DIAGRAMS AND NOTES PROPOSED FLOOR PLAN AND NOTES PROPOSED ROOF PLAN, ROOM, SCHEDULES AND NOTES PLUMBING DIAGRAMS, SCHEDULES AND NOTES DATE NO. REMARKS PROPOSED ELEVATIONS BUILDING SECTION AND FRAMING PLAN JOIST DETAILS CERTIFICATION STATEMENT SCOPE OF WORK NILES CENTER RD I HEREBY CERTIFY THAT THESE DRAWINGS ARE PREPARED BY ME OR UNDER MY SUPERVISION AND TO THE BEST OF MY REVISIONS PROFESSIONAL KNOWLEDGE CONFORM TO SKOKIE IL BUILDING CODES. SHEET TITLE APPLICABLE CODES COVER SHEET, N 1 GENERAL NOTES, CODE MATRIX AND SITE PLAN PHASE: SCALE: DATE: SHEET NUMBER SIGNED EXPIRED 11/30/2024 T1 9023 NILES CENTER RD 2ND FLOOR ADDITION 9023 NILES CENTER RD SKOKIE, IL 60076 ARCHITECT OF RECORD VARIATION DESIGN LLC CONTACT KLARKE ZHAOCHEN WANG, AIA TEL (626)675-0052 EMAIL VARIATIONDESIGNLLC@GMAIL.COM PROFESSIONAL DESIGN FIRM # 184.007945-0001 DATE NO. REMARKS REVISIONS SHEET TITLE FRONT FACADE RENDERING The image is a rendering only. The color as shown may vary from existing condition. The entire 2nd floor addition is intended to be applied with the same brick veneer matching texture and color of the existing 1st floor. PHASE: SCALE: DATE: SHEET NUMBER T2 FRONT REAR SIDE SIDE NEIGHBORS F RONTE NTRYE LEVA TION FI NISH LEGEND SHERWI NWI LLI AMS“ REPOSEGRAY” SHERWI NWI LLI AMS“ IRONORE” SHERWI NWI LLI AMS“ PAVESTONE” SHERWI NWI LLI AMS“ ORI GAMIWHI TE” SHERWI NWI LLI AMS“ ROOKWOODRED” SHERWI NWI LLI AMS“ PEPPERCORN” SHERWI NWI LLI AMS“ BLACKMAGI C” SUNBRELLA“ BEAUFORTCLASSI C” SUNBRELLA“ DUBONNETTWEED” SUNBRELLA“ BLACK” SI DEE LEVA TION WOOD- LOOKPLAN“ DARKWALNUT” DATE:06- 07- 2022 Col oredEl evat ions SCALE:1/ 8”=1’ -0” GHAAr chi tect ure/Devel opment MAGGIANO’SLI TTLEITAL Y 14901Quor um Dr ive,Suit e300 0 8 Ol dOrchar d-Skoki e,I L Dal las,Texas75254972.239.8884 Village of Skokie APPEARANCE COMMISSION APPLICATION Community Development Department - Building & Inspection Services Division 5127 Oakton St. Skokie, IL 60077 Phone 847/933-8223 The Appearance Commission meets the 2nd Wednesday* of each month at 7:30 p.m. *Unless otherwise noted Applications will only be accepted in a PDF format. APPLICATION DATE: 3/27/2024 _____________________________________ APPLICATION TYPE (Please check all that apply): (TENANT BUILD-OUT) New Construction 1st Floor Addition 2nd Floor Addition Façade Signage X Other LAND USE: Single Family Residential Multifamily Residential Mixed Use X Commercial Industrial Other 4999 OLD ORCHARD SHOPPING CENTER, SUITE A28A, SKOKIE, IL 60077 SUBJECT ADDRESS: ___________________________________________________________________________ OWNER INFORMATION: Please print legibly. NAME(S): ALEXIOS GEORGES ADDRESS: 4999 OLD ORCHARD SHOPPING CTR, STE A28A CITY, STATE ZIP: SKOKIE, IL 60077 PHONE#: 312-502-8994 EMAIL: ALEX@CUPITOL.COM AGENT/PETITIONER INFORMATION (if other than owner): NAME(S): LASZLO SIMOVIC DAYTIME PHONE #: 773-338-2225 ____________________________ ADDRESS: 6512 N. ARTESIAN AVE. CITY, STATE ZIP: CHICAGO, IL 60645 ______________________________ EMAIL: LSAOFFICE@LASZLOARCH.COM SIGNATURE: __________________________________ Please submit the following PDFs to appearance@skokie.org to complete your digital-only application: 1. Elevations, floor plans, and site plans. Scale ¼” = 1’-0” is preferred, but not required. If the file size is greater than 5MB, multiple emails are allowed. Ensure “Appearance Commission PDF” and the project’s property address are in the subject line of the email. Color elevations or one color rendering is required. 2. Completed Zoning Information Worksheet (residential projects only) N/A, NON-RESIDENTIAL 3. Photographs (all sides of the subject building and the fronts of neighboring buildings) 4. Excerpts of brochures and/or cut sheets of new materials and colors proposed for the project. Matching existing materials and colors can be confirmed with the submitted photographs. 5. Plat of Survey Does your project include a green roof? Yes No X * If your project includes a green roof you will placed at or near the top of the agenda. Fee Schedule Residential Site (new) … $100 plus $50.00 per unit Non-Residential Site* (new) … $100 plus $50.00 per 1,000 square feet (based on square footage of building) * Any non-residentially zoned site (Business, Industrial, Mixed-Use districts) Any Other Appearance Review (Additions, Façade, Sign Package, etc.) … $50.00 If you have already paid for a preliminary plan review there is no charge. For Office Use Only: Case Number ____________________________ Meeting Date ________________________________________________ Acct # NR Amt $ _________________________ Cash / Credit Card/ Check # ____________________________________ Any required fees or monies owed by the applicant to the Village must be paid as a condition of approval . VOSDOCS-#149808-v15-Appearance_Commission_Application_form Revised 12/4/23 INDEX OF DRAWINGS: T-0: COVER SHEET "CUPITOL" T-1: RENDERINGS LASZLO SIMOVIC, ARCHITECTS, L.L.C. T-3: EXTERIOR SAMPLE BOARD ARCHITECTURAL: TEL: 773-338-2225 A-0.1: BARRICADE PLAN A-0.2: BARRICADE ELEVATIONS A-1: NOTES AND LEGENDS NEW RESTUARANT SUITE A28A A-2: EXISTING BASEMENT PLAN A-3: DEMO 1ST FLOOR PLAN 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 A-4: DEMO ELEVATIONS A-5: NEW 1ST FLOOR PLAN A-6: NEW ROOF PLAN A-7: NEW ELEVATIONS A-8: BUILDING SECTIONS 4999 OLD ORCHARD SHOPPING CENTER SALES AREA CEILING GENERAL NOTES: 1. ACT OR LAY-IN TILE CEILING IS PROHIBITED AT FRONT-OF-HOUSE / A-9: WALL SECTIONS SUITE A28A SALES AREA AND WHERE OPENLY VISIBLE AT ANY BOH AREAS BY MEANS OF PASS-THROUGH WINDOWS. EMAIL: LASZLO@LASZLOARCH.COM 2. SECURITY CAMERAS WITHIN SALES AREA MUST BE DOME-TYPE AND LIFE SAFETY: SKOKIE, IL 60077 RECESSED WITHIN CEILING. ANY EXPOSED HOUSING MUST BE PAINTED TO MATCH CEILING FINISH COLOR, NO EXCEPTIONS. SUBMIT LS-1 LIFE SAFETY PLANS FAX: 773-338-2226 CUT SHEET FOR REVIEW AND APPROVAL. NO CLG MOUNTED SECURITY FIXTURES, MUST BE FULLY CONCEALED. NO CLG MOUNTED MONITORS. STRUCTURAL: 3. SPRINKLERS WITHIN SALES AREA MUST BE RECESSED AND S-1: CAPPED. S-2: SPRINKLER CAPS MUST MATCH COLOR OF ADJACENT CEILING FINISH, S-3: OWNER / DEVELOPER NO EXCEPTIONS. *CAPS ARE NOT ALLOWED TO BE PAINTED IN-FIELD S-4: AND MUST BE SUPPLIED COLORED BY MANUFACTURER, PER CODE. MECHANICAL: 4. HVAC DIFFISUSERS AND RETURNS WITHIN SALES AREA MUST BE ARCHITECTURAL LINEAR OR SINGLE PLATE (SEE OMNI BY TITUS HVAC MR. CHRIS GEORGES OR SIMILAR). DIFFUSERS AND RETURN AIR GRILLES MUST MATCH COLOR OF ADJACENT CEILING FINISH, NO EXCEPTIONS. SUBMIT CUT M-1: M-2: CUPITOL SHEETS AND SPECIFY WITHIN MECHANICAL DRAWINGS FOR REVIEW AND APPROVAL. M-3: 5. EMERGENCY LIGHTS MUST BE THROUGH SPECIFIED M-4: ARCHITECTURAL LIGHTING BY USING E-INVERTER (OR SIMILAR). NO BUG-EYES ALLOWED. EMERGENCY EXIT SIGNS SHALL BE EDGE-LIT ELECTRICAL: ARCHITECT BLADE TYPE WITH RECESSED BALLAST (WALL OR CEILING MOUNT). SUBMIT CUT SHEET FOR REVIEW AND APPROVAL. 6. ALL ACCESS PANELS AND HARDWARE MUST BE FINISHED TO MATCH E-1: ADJACENT CEILING COLOR FINISHES, NO EXCEPTIONS. DRYWALL E-2: LASZLO SIMOVIC E-3: ACCESS PANELS (SUCH AS MOONLIGHT MOLDS) ARE STRONGLY PREFERRED OVER METAL HINGED DOORS. CONSULT GC WHERE BEST APPLICABLE. ACCESS PANELS SHOULD BE LOCATED AWAY FROM E-4: 01/30/2024 LASZLO SIMOVIC ARCHITECTS, LLC FOCAL POINT AREAS. 7. IF OPEN CLG THEN FIRST 10'+/- MUST BE GYP BOARD WITH PLUMBING: 02/16/2024 01/19/2024 01/19/2024 DATE: RECESSED FIXTURES. 6512 N. ARTESIAN AVE 8. TRACK LIGHTS MAY NOT BE SURFACE MOUNTED ON SHEET ROCK. CLGS TRACK LIGHTS NEED TO BE FULLY RECESSED EITHER 1.IN P-1: P-2: CHICAGO, IL 60645 RECESSED NICHE OR 2. A SPEC WITH FULLY RECESSED TRACK (TAPED INTO CLG) IS SUBMITTED TO & APPROVED BY URW. P-3: 9. TRANSFER GRILLS ARE REQUIRED FOR SMOKE EVAC IN CERTAIN P-4: Design Review Added Supply/Waste AREAS OF THE CENTER (SEE CRITERIA). GRILLS SHOULD BE LINEAR Design Review Reflected Clg Plan AND PAINTED TO MATCH THE WALLS. STRUCTURAL ENGINEER PROGRESS PRINTING ______________________ DESCRIPTION: ______________________ Design Review Design Review OLD ORCHARD ROAD ______________________ MEP ENGINEER NO. ______________________ ______________________ FOREVER XXI ______________________ BLOOMINGDALES LANDLORD WESTFIELD OLD ORCHARD CONTACT: JINYOUNG JANG LEASE OUTLINE DRAWING PHONE: 872-227-4067 1.THIS LOD IS DIAGRAMMATIC ONLY. ACTUAL EMAIL: JINYOUNG.JANG@URW.COM CONDITIONS MAY VARY. 2.INDICATE LEASE LINE ON ALL PLANS. 3.FIELD VERIFY ALL CONDITIONS PRIOR TO START OF WORK. 4.TENANT MUST VERIFY ALL CONDITIONS PRIOR TO START OF WORK AND ADHERE TO ALL 4999 OLD ORCHARD DPT3 DIMENSIONS INDICATED ON THE LEASE OUTLINE DOCUMENT. PROJECT: 5.NO TENANT BUILD-OUT (STOREFRONT, PARKING PARKING FINISHES, FRONT COUNTER, EQUIPMENT, DOORS SHOPPING CENTER DECK DECK SWING, ETC.) IS PERMITTED BEYOND TENANT LEASE LINE UNLESS APPROVED BY LANDLORD. LAWLER AVE PRELIMINARY DRAWING REVIEW STE A28A APPROVED ✔ APPROVED AS NOTED RESUBMIT NEW RESTAURANT SKOKIE BOULEVARD Landlord review is for design intent and compliance with Landlord’s criteria ONLY. DPT 2 SKOKIE, IL 60077 It is the responsibility of the Tenant, Tenant’s Consultants, and Tenant’s General MACY'S Contractor to field verify all site conditions to ensure the work represented herein, satisfactorily meets Landlord’s design criteria and the requirements of all local, state, and Federal building codes, laws, acts, rules, regulations, ordinances, permitting requirements, inspections, and reviews, including but not limited to the Americans with Disabilities Act, and Fire Life Safety. Approval of Tenant’s plans by Landlord does not constitute an assumption of responsibility by Landlord for their accuracy or sufficiency as intended for construction or permitting, and in no way supersedes any provision of Tenant’s Lease. tricia.zeitler 3/4/2024 URW REPRESENTATIVE DATE RETAIL DESIGN MANAGER GENERAL NOTES (if applicable): "CUPITOL" 1. TENANT DESIGN REPRESENTATIVES AND GC. TO VERIFY ALL FIELD DIMENSIONS AND CONTACT TC WITH ANY SITE DISCREPENCIES THAT MAY AFFECT THE DESIGN. AREA OF WORK 2. DURING CONSTRUCTION, TENANT DESIGN PROFESSIONALS OF RECORD ARE RESPONSIBLE TO BE ON SITE TO FIELD VERIFY CONSTRUCTION PROGRESS AND EVALUATE POSSIBLE ISSUES CAUSED BY SITE CONDITIONS. ALL CHANGES MUST BE REVIEWED AND DISCUSSED WITH THE TC. AREA OF WORK 3. TENANT IS TO BUILD WHAT IS REPRESENTED IN THESE DRAWINGS ALONG WITH LANDLORD COMMENTS. IF THERE ARE CHANGES DUE TO TENANT’S INTERNAL OPERATIONS/DECISIONS, EXISTING CONDITIONS, OR BUILDING DEPARTMENT COMMENTS THEN THE TENANT ARCHITECT MUST PROMPLY ISSUE A SKETCH DRAWING (SK) TO LANDLORD FOR FURTHER APPROVAL. TENANT IS RESPONSIBLE TO RETAIN ARCHITECT FOR SUCH DRAWINGS AS ARE NECESSARY. NON-CONFORMING WORK WILL BE REJECTED AND THE TENANT WILL BE RESPONSIBLE FOR THE COST ASSOCIATED WITH RECTIFYING THE WORK AS REQUESTED BY URW. 4.TENANT GC TO HAVE LANDLORD REVIEWED DRAWINGS ONSITE AT ALL TIMES. 5.TENANT ARCHITECT IS RESPONSIBLE FOR CHECKING ALL LOCAL & ADA CODE COMPLIANCE. FOR RENOVATIONS TENANT'S ARCHITECT IS RESPONSBILE TO REVIEW CODE & BRING STORE UP TO CURRENT CODES AS NEC. 6. TENANT’S GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PROPERLY PROTECT ANY COMMON AREAS SURROUNDING THE LEASE PREMISE OR COMMON AREAS BEING UTILIZED AS PATH OF TRAVEL. 7. ANY COMMON AREAS DETERMINED TO BE DAMAGED BY THE TENANT’S GENERAL CONTRACTOR, REPAIRS AND ANY COSTS INCURRED IS THE RESPONSIBILITY OF THE TENANT’S GC. OWNER: 8. NO TENANT FINISH MAY PROJECT BEYOND LEASE LINE. 9. STOREFRONT MUST BE SELF SUPPORTING. TENANT CAN ONLY USE LANDLORD BULKHEAD FOR LATERAL ____________ SUPPORT. 10. ANY STRUCTURAL STEEL REQUIRED FOR STOREFRONT MUST BE FURNISHED AND INSTALLED BY TENANT. 11.TENANT MUST MAINTAIN 10’-0” CLEAR FIRE COORIDOR IN FRONT OF LEASE LINE. NO EXCEPTIONS. ____________ 12.TENANT TO RELOCATE ANY LIFE SAFETY KNOX BOX/HORN/STROBE/SPEAKER DEVICES THAT ARE CURRENTLY LOCATED ON THEIR STOREFRONT TO THEIR NEW STOREFRONT. 13.STOREFRONT METAL TO BE MIN OF .063 THINKNESS TO AVOID OIL CANNING/CRIMPING AT FASTENERS. PARKING 14.TENANT TO SUBMIT MATERIAL SAMPLE BOARD FOR LANDLORD APPROVAL PRIOR TO START OF CONSTRUCTION. DECK NO MATERIAL CONSIDERED APPROVED UNTIL MATERIAL SAMPLES ARE RECEIVED AND REVIEWED BY LANDLORD. SHEET NAME: RETENTION 15.TENANT TO SUBMIT SIGN SHOP DRAWINGS UNDER SEPARATE COVER FOR LANDLORD APPROVAL. NO SIGNS CONSIDERED APPROVED UNTIL ALL SHOP DRAWINGS ARE RECEIVED AND REVIEWED BY LANDLORD. DPT 1 Cover Sheet 16. NO COLOR CHANGING LIGHTS OR SIGNS ON STOREFRONT. NORDSTROM POND 17. OPEN CLGS ONLY PERMITTED WITH SPECIAL APPROVAL AND NOT WITHIN 5' OF LEASE LINE. 18. OPEN CEILING ON SALES FLOOR MUST UTILIZE CABLE TRAYS IF RIGID CONDUIT IS NOT USED. NO LOOSE MC CABLE OR LOOSE WIRING. 19. OPEN CEILING ON SALES FLOOR MUST HAVE RIGID DUCTWORK (NO FLEX DUCTS). 20. DIGITAL MONITORS TO BE SET BACK AT LEAST 5' FROM LEASE LINE. PROJECT: 7438 21. ALL TVS /MONITORS /LIGHT BOXES MUST BE RECESSED INTO WALL OR BE FRAMED OUT WITH ONLY SCREEN VISIBLE - NO VISIBLE CORDS - SCALE: AS NOTED 22.ALL SPRINKLER HEADS MUST BE RECESSED WITH COVER TO MATCH CEILING. 23.ALL EMERGENCY AND EXIT LIGHTING IN SALES AREA MUST HAVE RECESSED BASE AND BE FLUSH / EDGE-LIT LED DATE: 08/20/2023 (GREEN LETTERS)- NOT SURFACE MOUNTED. NO "BUG-EYES" PERMITTED IN SALES AREA. 24.MINIMUM PASSAGE WIDTH 36" CLEAR AISLES. TYPICAL THRU-OUT 25. NO ADDITIONAL DISPLAYS, FURNITURE, SIGNS AND ACCESSORIES ARE ALLOWED OTHER THAN THE ITEMS PRESENTED ON THE DESIGN PACKAGE. CHANGES TO THE CONCEPT’S LAYOUT AND DESIGN MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE TCM. 26. VISUAL COMMUNICATION: ALL DESCRIPTIONS AND PRICING SHOULD BE PROFESSIONALLY DESIGNED AND GOLF ROAD T-0 PRINTED. ENSURE TICKETING IS LAMINATED AND CONSISTENT IN APPEARANCE. PROFESSIONAL TICKET HOLDERS ARE TO BE USED AND PLACED IN A CONSISTENT FORMAT. REFER TO VISUAL COMMUNICATION GUIDE SUMMARY FOR ADDITIONAL INFORMATION. 27. TRASH CANS MUST BE FULLY CONCEALED FROM CUSTOMER LINE OF SIGHT, BEHIND COUNTER OR BUILT INTO THE MILLWORK. N N SITE PLAN KEY PLAN 28. ALL STAFF’S PERSONAL ITEMS MUST BE HIDDEN AT ALL TIMES. PERSONAL ELECTRONICS MAY NOT BE PLACED ON THE DISPLAYS AND COUNTERTOPS. 29. ALL COUNTER TASK LIGHTING LIKE DESK LAMPS ETC. MUST BE OUT OF CUSTOMER VISIBITY AND WIRING TO BE CONCEALED WITHIN MILLWORK. FIXTURE FINISH TO BE COHERENT WITH OVERAL PALETTE OF CONCEPT. SCALE: N.T.S. 30. NO EXPOSED SECURITY PEDS OR DOOR MAX, SECURITY SYSTEMS MUST BE FULLY CONSEALED. SCALE: 1" = 200' Tenant to submit sign shop drawings for landlord approval prior to start of construction. No sign considered approved until sign shop drawings LASZLO SIMOVIC, ARCHITECTS, L.L.C. are received and reviewed by Landlord. TEL: 773-338-2225 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 EMAIL: LASZLO@LASZLOARCH.COM FAX: 773-338-2226 02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE: Design Review Reflected Clg Plan Design Review Added Supply/Waste PROGRESS PRINTING Design Review Design Review DESCRIPTION: NO. EAST ELEVATION RENDERING SCALE: N.T.S. Cupitol is responsible for re-building this pier examples or modern planters LANDLORD COMMENTS Tenant must return side back at least 5' and preferrably to die into bulkhead beyond. False 4999 OLD ORCHARD BLADE SIGN - SEE fronts are no longer PROJECT: LOCATION AND SIZE IN CRITERIA. permitted. No exceptions. SHOPPING CENTER WE WILL ALLOW ROUND BUT MUST BE MOUNTED AT CORRECT HEIGHT STE A28A ADN NO MORE THAN 18" NEW RESTAURANT SKOKIE, IL 60077 storefront needs lighting element such as sconces. otherwise propose alternative lighting element. OWNER: ____________ ____________ SHEET NAME: Renderings PROJECT: 7438 SCALE: AS NOTED DATE: 08/20/2023 Storefront needs green element to soften it. Add planters. T-1 EXTERIOR SAMPLE BOARD ONLY LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 EMAIL: LASZLO@LASZLOARCH.COM FAX: 773-338-2226 where is this lighting? hanging off canopy? please show in next round. 02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE: Design Review Reflected Clg Plan Design Review Added Supply/Waste PROGRESS PRINTING Design Review Design Review DESCRIPTION: NO. VUSUAL COMFORT & CO. COTSWOLD LANE SMALL PENDANT. OL 5431 WINDOWS & DOOR COMBINATIONS WINDOWS & DOOR COMBINATIONS 4999 OLD ORCHARD PROJECT: SHOPPING CENTER ALUMI SMARTIA 567 URBAN ALUMI SMARTIA 567 URBAN CUPITOL - OLD ORCHARD STE A28A PRELIMINARY DESIGN NEW RESTAURANT SKOKIE, IL 60077 SUITE 828A FEB 23, 2024 NOTE: METAL CLADDING AT CANOPY TO MACH ALUMNI SMARTIA 567 URBAN OWNER: ____________ ____________ SHEET NAME: Sample Board PROJECT: 7438 SCALE: AS NOTED DATE: 08/20/2023 SAMPLE CLADDING EXTERIOR CLADDING BOOST STONE - TARMAC 120X 278 T-2 LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 EMAIL: LASZLO@LASZLOARCH.COM ROOF LEVEL BUILDING ABOVE MAGGIANO'S BSMT SLAB ON GRADE FAX: 773-338-2226 • Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Barricade graphics must be full wrap, printed scrim graphic and must include the following: Color to be approved by Westfield Tenant Coordination. 15. No Smoking Policy • Store name and opening date on graphic returns • All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the • Website or email address for employment opportunities Smoking is prohibited on the premises, common areas or base building construction site. edges and backs with good quality primer/paint designed for wood surfaces to ensure good adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- • Language related to open location in mall during construction if applicable, i.e. “Visit our Existing gloss finish, Fauna. ID 10YY 18/074. Store near Nordstrom.” • All plywood joints need to be screwed down to framing to eliminate bowing and warping. 16. Storefront Barricade Policy • Install wind bracing as necessary to stabilize the barricade. At Westfield’s option, barricades will be constructed by Westfield at General Contractor’s expense. All • Barricade must be full height. In order to accommodate installation of Tenant canopy, barricade 17. Door Name & Address questions regarding barricade graphics requirements must be submitted to Tenant Coordinator before should be constructed in 2 sections, height of each section to be determined by height of Tenant General Contractor needs to have store name and address painted on back door. The address on the installing the barricade. front door area should be applied with the proper address sticker. Exact location must be approved by the canopy. Facilities Director. 1'-6" Barricades requirements are as follows: o Example: Barricade is 20’ high. If Tenant canopy is at 12’, lower section of barricade 16.1 • If underneath Landlord canopy: Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a would be up to 12’ high (bottom of Tenant canopy AFF), upper section to be 8’. Full wrap graphic required on lower section; upper would eventually be removed so graphic should be different than that of lower section. Refer to illustration below. • • 1 inch letters for metal rear doors 4 inch height white block letters, Arial font, installed on the inside lower right side of the storefront, 2½” from bottom of glazing to bottom of letters. Furthest glazing panel on the right, right justified. Not on doors, glazing panel only 6'-1" smooth grade and not textured. • • Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Color to be approved by Westfield Tenant Coordination. All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the edges and backs with good quality primer/paint designed for wood surfaces to ensure good 18. Quality of Workmanship General Contractor’s work shall be performed in a through, first class and workmanlike manner and shall 3'-4" adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- be in good usable condition at the date of completion thereof. If in Westfield’s judgment, the General gloss finish, Fauna. ID 10YY 18/074. Contractor’s work is not completed in a first class and workmanlike manner, Tenant will not be allowed to • All plywood joints need to be screwed down to framing to eliminate bowing and warping. open until said discrepancies are corrected. • Install wind bracing as necessary to stabilize the barricade. • Barricade must be full height, to bottom of canopy or top of parapet wall.= • Barricade to be 5’ from storefront. 19. Supervision • Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the General Contractor shall provide a full-time supervisor on site at all times when construction is being barricade is open to the atmosphere, top edge shall be level and secured structurally to the performed in retailer’s space. Failure to comply will result in immediate work stoppage until such time as building. At no time whatsoever will sandbags or water barrels be allowed. said supervisor is present. • Paver flooring inside the barricade must be protected. • Doors are allowed on the barricade if the premises does not have a back door. Door must be pre- 10'-3" hung, finished, & trimmed. 20. Approved Design • General Contractor must provide Facilities Director with a key to the premises. • Barricade to be 5’ from storefront. Retailer’s store shall be constructed in accordance with the plans, which have been approved by the • Barricade graphics are required and must be approved by Westfield. Graphics must be • Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the Tenant Coordinator. These plans will comply with all city, county, and state rules, ordinances and installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72 regulations relating thereto. If the store has not been constructed in accordance with said plans, the barricade is open to the atmosphere, top edge shall be level and secured structurally to the hours. retailer shall not be permitted to open the store for business based on the obligations under the retailer’s building. At no time whatsoever will sandbags or water barrels be allowed. lease. A copy of said plans must be kept on the job-site at all times during construction. Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in • Paver flooring inside the barricade must be protected. sections depending upon total length of barricade. Contractor to coordinate with Tenant to provide a • Doors are allowed on the barricade if the premises does not have a back door. Door must be pre- layout submittal to Facilities Director for approval prior to installation. hung, finished, & trimmed. • General Contractor must provide Facilities Director with a key to the premises. 02/16/2024 01/30/2024 • Barricade graphics are required and must be approved by Westfield. Graphics must be 21. Building Permit 01/19/2024 01/19/2024 Barricade graphics must be full wrap, printed scrim graphic and must include the following: installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72 hours. Retailer shall apply for all permits, coordinate building department submittal and pay all associated fees. 14'-2" • Store name and opening date on graphic returns Retailer shall apply for and obtain all approvals and permits from the local health department if required. • Website or email address for employment opportunities Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in Building permit shall be posted in retailer’s space before any work begins (i.e., demolition, rough framing, • Language related to open location in mall during construction if applicable, i.e. “Visit our Existing rough plumbing or electrical). A copy of the permits must be on file with the mall management office DATE: sections depending upon total length of barricade. Bottom and top sections of barricade to be framed. Store near Nordstrom.” Contractor to coordinate with Tenant to provide a layout submittal to Facilities Director for approval before work starts, and a copy must be placed in clear sight within the job space. prior to installation. 22. Security 7'-11" 16.2 • If Tenant building Tenant canopy: Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a smooth grade and not textured. Scrim description 10oz. Ultramesh, allow for a 3” bleed included outside the perimeter for mounting purposes underneath the frame. General Contractor shall ensure the security of premises by whatever measures it deems necessary including the re-keying of all locksets. 10'-10" BARRICADE SPECIFICATIONS Revision date 07.19.2021 Revision date 07.19.2021 Revision date 07.19.2021 4'-0" 3'-11" 1'-10" LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ 18'-4" Design Review Added Supply/Waste DISHWASHING 4 1/4" 3'-7 3/4" 3'-0" SCALE: 1/4" = 1'-0" Design Review Reflected Clg Plan 16'-0" x 2'-6" 4 1/4" PROGRESS PRINTING ALINE W/ MULLION 1'-11" 73'-6" BAR KITCHEN Design Review Design Review DESCRIPTION: 9'-0" x 3'-0" 17'-0" x 2'-8" COOLER 8'-2" x 8'-0" NO. DISPLAY 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS BAR 9'-10" x 3'-0" KITCHEN HELP 17'-0" x 4'-4" @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR WATER ROOM WASTE WATER LINE SUPPLY RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. - TOILET 33'-0" RM #4 TOILET RM #3 EMER. EXIT ONLY SEE SECTIONS ABOVE. 36'-5 3/8" TYP. 4'-0" SECTIONS DINING ROOM DINING ROOM #1 #2 43'-11 1/4" (V.I.F.) 43'-2 3/4" 4999 OLD ORCHARD TOILET PROJECT: POINT OF RM #2 SALES TOILET SHOPPING CENTER DINING ACCESS 2'-8" x 14'-0" CORR. TOILET 1 RM #1 STE A28A ENTRY/ WAITING A-0.2 28'-6" x 19'-3" NEW RESTAURANT SKOKIE, IL 60077 3'-0" 7 3/4" 112'-1" 3'-0" PROTECTIVE COVERNING OVER LINE OF CANOPY PAVER FLOORING WITHIN BARRICADE 9'-0" 8'-0" 9'-0" 6'-0" 3'-0" x 7'-0" DOOR TYP. 4'-0" SECTIONS OWNER: 4 1/4" 4 1/4" 4 1/4" 2'-0" 4 1/4" ____________ ____________ 82'-1 3/4" 40'-0 1/4" ER 3 1 E BY OW N 2 SEWER LIN 122'-6 1/4" (V.I.F.) A-0.1 A-0.1 A-0.1 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS SHEET NAME: WATER 2 PROJECT TRUE @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR 2 SUPPLY Barricade Plan NORTH NORTH RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. - SEE SECTIONS ABOVE. A-0.2 BARRICADE PLAN SCALE: 1/4" = 1'-0" A-0.2 PROJECT: 7438 SCALE: AS NOTED DATE: 08/20/2023 A-0.1 20'-0" 14'-6" 1'-9" 3'-7 1/2" 13'-3 3/4" 6'-8 1/4" 4'-0" TYP. 4 X 8 PLYWD SHTS 20'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" SCALE: 1/4" = 1'-0" 3068 SCALE: 1/4" = 1'-0" TYP. 4 X 8 PLYWD SHTS TYP. 4 X 8 PLYWD SHTS EAST BARRICADE ELEVATION NORTH BARRICADE ELEVATION 12'-0" 9'-10" 1'-5" 11'-3" EL. + 11'-3" EL. +/- 0'-0" BOT MTL DECK EL. + 9'-10" FINISHED FLOOR FINISHED CEILING 17'-11" 2'-4" EL. +/- 0'-0" EL. + 20'-3" EL. + 13'-0" TOP PARAPET FINISHED FLOOR FINISHED CEILING PROGRESS PRINTING OWNER: PROJECT: ____________ NEW RESTAURANT Design Review 02/16/2024 LASZLO SIMOVIC, ARCHITECTS, L.L.C. PROJECT: 7438 ____________ Design Review Reflected Clg Plan 01/30/2024 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 SCALE: AS NOTED 01/19/2024 DATE: 08/20/2023 4999 OLD ORCHARD Design Review Added Supply/Waste EMAIL: LASZLO@LASZLOARCH.COM Barricade Elevations SHEET NAME: SHOPPING CENTER Design Review 01/19/2024 FAX: 773-338-2226 TEL: 773-338-2225 STE A28A NO. DESCRIPTION: DATE: A-0.2 SKOKIE, IL 60077 14'-6" 1'-9" 13'-3 3/4" 19'-10 1/2" 13'-2" 13'-10 1/4" SCALE: 1/4" = 1'-0" 3068 SCALE: 1/4" = 1'-0" EXIST'G PARTIAL SOUTH ELEVATION EXIST'G PARTIAL EAST ELEVATION 9'-10" 1'-5" 11'-3" EL. + 11'-3" EL. +/- 0'-0" BOT MTL DECK EL. + 9'-10" FINISHED FLOOR FINISHED CEILING 0 SCALE 1/4" = 1'-0" 5 10 17'-11" 2'-4" PARTITION CONSTR. TYPE 15 EL. +/- 0'-0" EL. + 20'-3" EL. + 13'-0" INCLUD'G UL # - SEE SHEET A-__ TOP PARAPET FINISHED FLOOR FINISHED CEILING 20 FT PROGRESS PRINTING OWNER: PROJECT: ____________ NEW RESTAURANT Design Review 02/16/2024 LASZLO SIMOVIC, ARCHITECTS, L.L.C. PROJECT: 7438 ____________ Design Review Reflected Clg Plan 01/30/2024 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 SCALE: AS NOTED 01/19/2024 DATE: 08/20/2023 4999 OLD ORCHARD Design Review Added Supply/Waste EMAIL: LASZLO@LASZLOARCH.COM Existing Elevations SHEET NAME: FAX: 773-338-2226 TEL: 773-338-2225 A-4 SHOPPING CENTER Design Review 01/19/2024 STE A28A NO. DESCRIPTION: DATE: SKOKIE, IL 60077 SPEAKERS/SECURITY CAMERAS SHOULD BE RECESSED, NOT SURFACE MOUNTED LAWLER AVE LASZLO SIMOVIC, ARCHITECTS, L.L.C. RETENTION POND NO DIGITAL SCREENS WITHIN 5' OF WINDOW. PARKING PARKING BLOOMINGDALES DECK DECK TEL: 773-338-2225 FOREVER XXI K10 LANDLORD MILLWORK GENERAL NOTES: SALES AREA CEILING GENERAL NOTES: 1. ACT OR LAY-IN TILE CEILING IS PROHIBITED AT FRONT-OF-HOUSE / GOLF ROAD DPT 1 NORDSTROM DPT 2 MACY'S OLD ORCHARD ROAD 1. MILLWORK AND FLOOR FIXTURES GENERAL NOTES: ALL TCM COMMENTS AND DESIGN DIRECTION REGARDING GENERAL SALES AREA AND WHERE OPENLY VISIBLE AT ANY BOH AREAS BY 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 MILLWORK (IE CASHWRAPS, SERVICE COUNTERS, WALL SHELVING SYSTEMS, PRODUCT DISPLAYS, ETC) MUST BE FULLY MEANS OF PASS-THROUGH WINDOWS. DPT3 INCORPORATED INTO SHOP DWGS AND SUBMITTED TO TCM FOR REVIEW AND APPROVAL, PRIOR TO FABRICATION. 2. CUT SHEETS FOR MERCHANDISE APPARATUS SUCH AS MANNEQUINS AND COUNTERTOP DISPLAYS MUST BE SUBMITTED FOR 2. SECURITY CAMERAS WITHIN SALES AREA MUST BE DOME-TYPE AND REVIEW AND APPROVAL. RECESSED WITHIN CEILING. ANY EXPOSED HOUSING MUST BE 3. ALL FIXTURES TO BE UL-RATED AS AN ASSEMBLY. FLOOR FIXTURES TO BE A MAXIMUM OF 4'-0" HIGH. ALL MILLWORK & WOODS PAINTED TO MATCH CEILING FINISH COLOR, NO EXCEPTIONS. SUBMIT PARKING DECK TO MEET LOCAL CODE FLAMMABILITY REQUIREMENTS. 4. ALL UPHOLSTERY / FABRICS MUST MEET LOCAL CODE FLAMMABILITY REQUIREMENTS AND HAVE A COMMERCIAL-GRADE CUT SHEET FOR REVIEW AND APPROVAL. NO CLG MOUNTED SKOKIE BOULEVARD RATING OF 100,000 DOUBLE-RUBS OR GREATER. ALL FIXTURES & MILLWORK MUST BE PROPERLY PROTECTED AT EXPOSED SECURITY FIXTURES, MUST BE FULLY CONCEALED. NO CLG MOUNTED EDGES AND POINTS OF IMPACT BY USE OF NECESSARY CORNER GUARDS OR SPLINES. CORNER GUARDS MUST BE OF SLIM MONITORS. NORTH KEY PLAN DESIGN, RECESSED FLUSH AND POWDER COATED TO MATCH ADJACENT MATERIAL FINISHES FOR A CONSISTENT LOOK. 5. ALL MILLWORK AND DISPLAY FIXTURES ALONG WALLS MUST HAVE A BUILT-IN LOOK. ANY VOID CORNERS AND BULKHEAD 3. SPRINKLERS WITHIN SALES AREA MUST BE RECESSED AND SHALL BE FURRED OUT TO AVOID DEAD / HOLLOW AREAS AND CEILINGS DROPPED TO CREATE SOFFITS ABOVE FIXTURE CAPPED. FINISHES IN ORDER TO RECESS MILLWORK AND ACHIEVE A BUILT-IN LOOK. ABUNDANT USE OF SLAT WALL IS NOT PERMITTED, AS SPRINKLER CAPS MUST MATCH COLOR OF ADJACENT CEILING FINISH, EMAIL: LASZLO@LASZLOARCH.COM THIS CREATES VISUAL CLUTTER AND OVERPOPULATION OF MERCHANDISE. NO EXCEPTIONS. *CAPS ARE NOT ALLOWED TO BE PAINTED IN-FIELD ROOF LEVEL SCALE: N.T.S. 6. CLUTTER AND OVER-MERCHANDISING IS NOT PERMITTED WITHIN SALES AREA AND IS AT TCM DISCRETION, PER DESIGN BUILDING ABOVE MAGGIANO'S BSMT SLAB ON GRADE CRITERIA. AND MUST BE SUPPLIED COLORED BY MANUFACTURER, PER CODE. 7. ALL POWER SOURCES & ELECTRICAL WIRING MUST BE FULLY CONCEALED FROM CUSTOMER SIGHTLINES; NO EXPOSED 4. HVAC DIFFISUSERS AND RETURNS WITHIN SALES AREA MUST BE FAX: 773-338-2226 POWER CORDS WILL BE PERMITTED TO RUN BETWEEN CASHIER STAND TO MILLWORK DIRECTLY BEHIND TO CAUSE TRIP HAZARD; NO MATS WILL BE PERMITTED TO CONCEAL SUCH CONDITIONS - TYP NO OPEN, UNDER-COUNTER STORAGE ALLOWED ARCHITECTURAL LINEAR OR SINGLE PLATE (SEE OMNI BY TITUS HVAC WITHIN SALES AREA, INCLUDING CASHWRAP. OR SIMILAR). DIFFUSERS AND RETURN AIR GRILLES MUST MATCH 8. ALL STORAGE SHELVING MUST HAVE HINGED DOORS, WITH RECESSED / FLUSH LOCKS AND PULL HANDLES. COLOR OF ADJACENT CEILING FINISH, NO EXCEPTIONS. SUBMIT CUT 9. CONTINUOUS LED LIGHTING WITHIN FIXTURES MUST BE INSTALLED IN A RECESSED MANNER, WITHIN COVE OR OTHERWISE 19'-10" NOTED - AND A DIFFUSER MUST BE PROVIDED IN ORDER TO AVOID "HOT" OR "SHADOW" SPOTS REFLECTED ONTO MERCHANDISE. SHEETS AND SPECIFY WITHIN MECHANICAL DRAWINGS FOR REVIEW LED STRIP LIGHTING MUST BE INSTALLED IN A MANNER AS TO AVOID DIRECT SIGHTLINES OF THE "DOT PATTERN", WHICH AND APPROVAL. 3'-4" 5'-8" TYPICALLY SHOWS BY REFLECTION WITH USE OF GLASS AND MIRRORS. CONFIRM MILLWORK COMPONENTS AND BASE ARE 5. EMERGENCY LIGHTS MUST BE THROUGH SPECIFIED HIGHLY DURABLE AND IMPACT-RESISTANT TO ASSURE MINIMAL DAMAGE. 10. BASE OF FIXTURES TO BE METAL SUCH AS STAINLESS STEEL OR HEAVY GAUGE ALUMINUM AND MUST BE CONTINUOUS AND ARCHITECTURAL LIGHTING BY USING E-INVERTER (OR SIMILAR). NO BENT TO WRAP AT ALL EXPOSED EDGES, WITH MINIMAL SEAMS THAT ARE OUT OF CUSTOMER SIGHTLINES. RECESSED BASE BUG-EYES ALLOWED. EMERGENCY EXIT SIGNS SHALL BE EDGE-LIT DETAIL IS PREFERRED. 11. COUNTERTOPS TO BE SOLID SURFACE OR OTHER DURABLE MATERIAL AND MUST HAVE EASED, BEVELED OR RADIUS EDGES. 12. PLASTIC LAMINATES AND UNPROTECTED WOOD VENEERS USED FOR FIXTURE FINISHES ARE NOT ALLOWED. BLADE TYPE WITH RECESSED BALLAST (WALL OR CEILING MOUNT). SUBMIT CUT SHEET FOR REVIEW AND APPROVAL. 1'-6" 6'-1" 6. ALL ACCESS PANELS AND HARDWARE MUST BE FINISHED TO MATCH 3'-4" 13. ANY VISIBLE PRE-DRILLED HOLES IN MILLWORK, NOT USED FOR SHELVING OR MERCHANDISING APPARATUS IS NOT ALLOWED, TYP. STANDARDS AND MERCHANDISING HARDWARE MUST BE CONSISTENT TO MATCH WITH OVERALL MILLWORK FINISHES FOR ADJACENT CEILING COLOR FINISHES, NO EXCEPTIONS. DRYWALL A CONSISTENT LOOK. ALL HARDWARE, FASTENERS, UTINSIL HOLDERS AND COUNTERTOP MERCHANDISE APPARATUS THAT IS ACCESS PANELS (SUCH AS MOONLIGHT MOLDS) ARE STRONGLY 1'-6" EXPOSED AND WITHIN CUSTOMER SIGHTLINES MUST BE COUNTERSUNK, FLUSH AND PAINTED TO MATCH ADJACENT SURFACE FINISHES FOR AN OVERALL CLEAN APPEARANCE. PREFERRED OVER METAL HINGED DOORS. CONSULT GC WHERE BEST 14. FLOOR FIXTURES ON ROLLING CASTERS MUST BE ABLE TO LOCK-IN-PLACE DURING OPERATIONAL HOURS. CASTERS AND APPLICABLE. ACCESS PANELS SHOULD BE LOCATED AWAY FROM ATTACHMENT HARDWARE MUST BE RECESSED FROM MILLWORK FACE AND A "SKIRT" BASE MUST BE INCORPORATED INTO MILLWORK DESIGN TO CONCEAL CASTERS. FOCAL POINT AREAS. 15. SNEEZGUARDS AND/OR CLEAR GLASS SHROUDS MUST BE OF LOW-IRON [PPG STARPHIRE OR EQUIV.] AND MUST BE 7. IF OPEN CLG THEN FIRST 10'+/- MUST BE GYP BOARD WITH UV-BONDED / FUSED AT JOINTS. RECESSED FIXTURES. 16. SILICONE JOINTS ARE STRICTLY PROHIBITED, NO EXCEPTIONS. TEMPORARY & PROMOTIONAL DISPLAY FIXTURES AND NEW 8. TRACK LIGHTS MAY NOT BE SURFACE MOUNTED ON SHEET ROCK. 10'-3" MILLWORK OR MERCHANDISE DISPLAY SYSTEMS NOT PRESENTED WILL NOT BE PERMITTED WITHOUT FORMAL REVIEW AND APPROVAL. CLGS TRACK LIGHTS NEED TO BE FULLY RECESSED EITHER 1.IN 38'-2" 10'-3" 17. P.O.S. EQUIPMENT MUST BE FULLY INTEGRATED AND CONCEALED WITHIN CASHWRAP MILLWORK AND ANY SHROUDS MUST RECESSED NICHE OR 2. A SPEC WITH FULLY RECESSED TRACK BE PROVIDED FOR COUNTERTROP MONITORS. 18. ALL WIRES AND DOCK STATION MUST NOT BE VISIBLE TO CUSTOMERS WITHIN SALES AREA. P.O.S. AREA MUST BE CLEAN AND (TAPED INTO CLG) IS SUBMITTED TO & APPROVED BY URW. CLUTTER-FREE AND CONFIGURATION MUST BE INCORPORATED INTO OVERALL STORE'S DESIGN. P.O.S. MUST COMPLY WITH ALL 9. TRANSFER GRILLS ARE REQUIRED FOR SMOKE EVAC IN CERTAIN K10.7 ACCESSBILITY REQUIREMENTS. AREAS OF THE CENTER (SEE CRITERIA). GRILLS SHOULD BE LINEAR 02/16/2024 01/30/2024 19. ALL IMPLUSE FIXTURES AT POS MUST BE INTEGRATED WITH THE OVERAL CONCEPT. 01/19/2024 01/19/2024 14'-3 7/8" 20. ENSURE FIXTURES AND CASHWRAP ARE ADA COMPLIANT AND CODE COMPLIANT AS REQ'D BY ALL LOCAL CODES AND AND PAINTED TO MATCH THE WALLS. 9'-0" 10'-10 1/8" 10'-8 7/8" 5" 7'-2" Tenant must show 14'-2" JURISDICTIONS elevation at parapet above DATE: maggiano's 10'-10" DISHWASHING 1'-10" 1'-10" 18'-4" Design Review Added Supply/Waste 3'-0" Tenant must show 2'-0" 11'-0" 2'-6" 18'-3" 1'-0" 6'-0" 1'-0" 19'-0" 4'-0" 8'-6 1/2" 5" Design Review Reflected Clg Plan 16'-0" x 2'-6" demolition and construction 2'-5 3/4" plans including existing pier, 3'-10 1/2" 3'-0" PROGRESS PRINTING storefront, awning 16'-0" 4'-0" 1'-1" 2'-6" 73'-6" 5'-7" 8 7/8" DESCRIPTION: 5" Design Review Design Review 5" K11 20'-0" 2'-0" 2'-0" 3'-0" 2'-6" 5" 3'-0" 8'-2" 3'-0" 4'-6 1/8" BAR KITCHEN 2'-8" 9'-0" x 3'-0" 17'-0" x 2'-8" 8'-11 1/2" 3'-0" 18'-1" 17'-1" COOLER 8'-0" 8'-2" x 8'-0" NO. 3'-0" 3'-0" DISPLAY 4'-6 1/4" 8'-6 1/4" 5" 11'-2" 5'-0" BAR KITCHEN HELP 11'-1 1/2" 9'-10" x 3'-0" 11'-0" 2'-1" 5" 45'-3" 4'-0" 3'-0" 17'-0" x 4'-4" 3'-0" WATER 3'-0" ROOM WASTE 2'-6" WATER LINE SUPPLY 3'-0" K11.4 5" 3'-6" 1'-6" TOILET MIN. 5'-0" 33'-0" 6" 3'-0" 6" 2'-6" 9'-10" 17'-8 1/2" 3'-0" RM #4 TOILET RM #3 5'-0" EMER. EXIT ONLY 36'-5 3/8" 27'-0 1/2" 3'-0" 3'-0" 2'-6" 2'-6" 5'-0" 30'-1 1/2" 6'-0 1/4" 28'-1 1/2" DINING ROOM 33'-0" 18'-0 3/4" 5" #1 1'-6" DINING ROOM #2 13'-4 1/2" 4'-9" 1'-6" 3'-10 5/8" 4999 OLD ORCHARD TOILET 21'-1 1/2" PROJECT: POINT OF RM #2 SALES TOILET 20'-0" SHOPPING CENTER DINING ACCESS 2'-8" x 14'-0" 5" CORR. TOILET RM #1 STE A28A ENTRY/ WAITING 8'-7 1/8" 13'-0" 4'-9" 16'-7 1/2" 5'-0" 28'-6" x 19'-3" NEW RESTAURANT SKOKIE, IL 60077 9" 5" 2'-6" 5" 5'-9" 5" 5'-0" 4'-9" 3'-9 1/2" 2'-0" 6'-1 1/4" K12 2'-6" 1'-9" 112'-1" 2'-0" 11'-0" 2'-6" 45'-3" 4'-0" 47'-1 1/2" 5" 3'-0" 5'-0" 5'-0" 7'-8" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 3'-6" 5'-0" 12'-0" 5'-0" 3'-6" 5'-0" 3'-4" 6'-4" 3'-4" 5'-0" 3'-6" 5'-0" 3'-2 1/2" If tenant uses patio at all then it must comply with guidelines. Tenant must show it on Final LOCATION OF TEMPOARARY 2'-6" VESTIBULE (COLD MONTHS ONLY) Drawing Submittal. It must 2'-6" seating & include railings, planters, lighting and optional heating. See attached guidelines that OWNER: 9'-6 7/8" are an addendum to the criteria. ____________ 1'-9" 12'-6" 20'-0" 20'-0" 10'-0" 16'-10" 13'-2" 30'-0" 111'-10 1/2" 30'-0" to KF ER ____________ XX KA SEWER LIN E BY OW N KB KB.7 KC KC.6 KD We cannot approve a full height structure outside SHEET NAME: lease line including a WATER temporary vestibule. If it's SUPPLY New Floor Plan PROJECT TRUE needed then it must be NORTH NORTH NEW 1ST FLOOR PLAN inside space. We recommend a curtain PROJECT: 7438 SCALE: 1/4" = 1'-0" 3,855 SF LEASED SPACE 2/1/24 situation inside door. PARTITION LEGEND SCALE: AS NOTED WALL TO REMAIN DATE: 08/20/2023 WALL TO BE REMOVED WALL FINISH TO BE REMOVED STUDS TO REMAIN A-5 WALL TO BE CONSTRUCTED PARTITION CONSTR. TYPE INCLUD'G UL # - SEE SHEET A-__ 0 5 10 15 20 FT SCALE 1/4" = 1'-0" LAWLER AVE LASZLO SIMOVIC, ARCHITECTS, L.L.C. RETENTION POND PARKING PARKING BLOOMINGDALES DECK DECK TEL: 773-338-2225 FOREVER XXI K10 OLD ORCHARD ROAD DPT 1 NORDSTROM DPT 2 GOLF ROAD MACY'S 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 DPT3 PARKING DECK SKOKIE BOULEVARD NORTH KEY PLAN EMAIL: LASZLO@LASZLOARCH.COM SCALE: N.T.S. FAX: 773-338-2226 EXIST'G RUBBER ROOF K10.7 02/16/2024 01/30/2024 01/19/2024 01/19/2024 DATE: Tenant must show elevation at parapet above maggiano's Design Review Reflected Clg Plan Design Review Added Supply/Waste PROGRESS PRINTING Design Review Design Review DESCRIPTION: K11 NEW EXTRUDED ALUMINUM COPING, COLOR TO MATCH EXTERIOR FINISH, TYP. NO. EXIST'G 2ND FLOOR (N.I.C.) K11.4 EXIST'G RUBBER ROOF NEW RUBBER ROOF TO MATCH EXIST'G 4999 OLD ORCHARD PROJECT: SHOPPING CENTER STE A28A NEW RESTAURANT SKOKIE, IL 60077 NEW EXTRUDED ALUMINUM COPING, COLOR TO MATCH EXTERIOR FINISH, TYP. K12 OWNER: ____________ ____________ XX KA KB KB.7 KC KC.6 KD SHEET NAME: New Roof Plan PROJECT TRUE NORTH NORTH NEW ROOF PLAN PROJECT: 7438 SCALE: 1/4" = 1'-0" 3,855 SF LEASED SPACE PARTITION LEGEND SCALE: AS NOTED WALL TO REMAIN DATE: 08/20/2023 WALL TO BE REMOVED WALL FINISH TO BE REMOVED STUDS TO REMAIN A-6 WALL TO BE CONSTRUCTED PARTITION CONSTR. TYPE INCLUD'G UL # - SEE SHEET A-__ 0 5 10 15 20 FT SCALE 1/4" = 1'-0" CUPITOL TENANT BUILD OUT NEW RESTAURANT TO REPLACE EXISTING RESTAURANT 4999 OLD ORCHARD SHOPPING CENTER,SUITE A28 SKOKIE, IL 60077 PROJECT TO COMPLY WITH: INDEX OF DRAWINGS: T-1: COVER SHEET 2021 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS TENANT 2014 STATE OF ILLINOIS PLUMBING CODE WITH LOCAL AMENDMENTS 2020 NATIONAL ELECRIC CODE WITH LOCAL AMENDMENTS 2021 INTERNATIONAL MECHANICAL CODE WITH LOCAL AMENDMENTS ARCHITECTURAL: A-0: BARRICADE PLAN ALEXIOS GEORGES 2021 INTERNATIONAL FUEL GAS CODE WITH LOCAL AMENDMENTS 2018 INTERNATIONAL ENERGY CONSERVATION CODE WITH ILLINOIS AMENDMENTS 2010 ADA DESIGN GUIDELINES A-0.1 A-6: BARRICADE ELEVATIONS NEW 1ST FLOOR PLAN 4999 OLD ORCHARD SHOPPING CENTER 2018 ILLINOIS ACCESSIBILITY CODE 2021 INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS A-7: A-8: NEW ROOF PLAN NEW ELEVATIONS SUITE A28 2021 LIFE SAFETY CODE A-13: ENLARGED FRONT ELEVATION SKOKIE, IL 60077 LANDLORD WESTFIELD OLD ORCHARD OLD ORCHARD ROAD CONTACT: JINYOUNG JANG PH: (872)227-4067 EMAIL: JINYOUNF.JANG@URW.COM ARCHITECT FOREVER XXI LASZLO SIMOVIC LASZLO SIMOVIC ARCHITECTS, LLC BLOOMINGDALES 6512 N ARTESIAN AVE CHICAGO, IL 60645 DPT3 PARKING PARKING DECK DECK LAWLER AVE SKOKIE BOULEVARD DPT 2 MACY'S "CUPITOL" AREA OF WORK AREA OF WORK PARKING DECK RETENTION I CERTIFY THAT I AM THE REGISTERED ENERGY PROFESSIONAL FOR THIS PROJECT. I ALSO CERTIFY THAT TO THE BEST OF DPT 1 MY PROFESSIONAL KNOWLEDGE AND BELIEF THE ATTACHED PLANS FOR: 4999 OLD ORCHARD SHOPPING CENTER, SUITE NORDSTROM POND A28A., SKOKIE, IL. 60077 DOES COMPLY WITH THE REQUIREMENTS OF CHAPTER 18-13, ENERGY CONSERVATION, OF THE MUNICIPAL CODE OF SKOKIE AS OF APRIL 22, 2009. SIGNED_____________________________________________DATE: MARCH 27, 2024 (ARCHITECT) ILLINOIS LICENSE NUMBER: 001-012275 THESE DRAWINGS ARE PREPARED UNDER MY SUPERVISION AND TO THE BEST OF MY KNOWLEDGE & BELIEF, ARE IN COMPLIANCE WITH THE VILLAGE OF SKOKIE BUILDING CODE. GOLF ROAD EXPIRES 11/30/24 N PROFESSIONAL DESIGN FIRM LICENSE NO. 184.006791 EXPIRES 4/30/2025 SITE PLAN N SCALE: N.T.S. C LASZLO SIMOVIC, ARCHITECTS 2024 KEY PLAN SCALE: 1" = 200' CUPITOL - OLD ORCHARD PRELIMINARY DESIGN SUITE 828A FEB 23, 2024 MARCH 23, 2024 C LASZLO SIMOVIC ARCHITECTS, LLC EXTERIOR SAMPLE BOARD ONLY CANOPY PENDANT LIGHTING EXTERIOR WALL LIGHTING MODEL # MODEL # WINDOWS & DOOR COMBINATIONS WINDOWS & DOOR COMBINATIONS ALUMI SMARTIA 567 URBAN ALUMI SMARTIA 567 URBAN SAMPLE POT W/ PLANT EXTERIOR CHAIRS & TABLES MODEL # MODEL # CUPITOL - OLD ORCHARD PRELIMINARY DESIGN SUITE 828A FEB 23, 2024 MARCH 23, 2024 SAMPLE CLADDING EXTERIOR CLADDING NOTE: METAL CLADDING AT CANOPY TOC MACH ALUMNI SMARTIA 567 URBAN LASZLO SIMOVIC ARCHITECTS, LLC BOOST STONE - TARMAC 120X 278 LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 MAGGIANO'S BSMT SLAB ON GRADE EXIST'G EXT. ROOF LEVEL BUILDING ABOVE WALL 1/4"/ FT PITCH 1/4"/ FT PITCH 1/4"/ FT PITCH EMAIL: LASZLO@LASZLOARCH.COM • Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Barricade graphics must be full wrap, printed scrim graphic and must include the following: Color to be approved by Westfield Tenant Coordination. 2'-0" 2'-0" 15. No Smoking Policy • Store name and opening date on graphic returns • All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the • Website or email address for employment opportunities Smoking is prohibited on the premises, common areas or base building construction site. edges and backs with good quality primer/paint designed for wood surfaces to ensure good • Language related to open location in mall during construction if applicable, i.e. “Visit our Existing adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- 18 GA. MTL 7'-7" (V.I.F.) FAX: 773-338-2226 Store near Nordstrom.” 16. Storefront Barricade Policy • gloss finish, Fauna. ID 10YY 18/074. All plywood joints need to be screwed down to framing to eliminate bowing and warping. EXIST'G 18 GA. MTL EXIST'G 18 GA. MTL FRAM'G 16" O.C. At Westfield’s option, barricades will be constructed by Westfield at General Contractor’s expense. All • • Install wind bracing as necessary to stabilize the barricade. 17. Door Name & Address PARAPET FRAM'G 16" O.C. PARAPET FRAM'G 16" O.C. Barricade must be full height. In order to accommodate installation of Tenant canopy, barricade WALL WALL V.I.F. V.I.F. questions regarding barricade graphics requirements must be submitted to Tenant Coordinator before should be constructed in 2 sections, height of each section to be determined by height of Tenant General Contractor needs to have store name and address painted on back door. The address on the installing the barricade. front door area should be applied with the proper address sticker. Exact location must be approved by the canopy. 22'-0". (V.I.F.) Barricades requirements are as follows: o Example: Barricade is 20’ high. If Tenant canopy is at 12’, lower section of barricade Facilities Director. ROOF 22'-0". (V.I.F.) 22'-0". (V.I.F.) 16.1 If underneath Landlord canopy: would be up to 12’ high (bottom of Tenant canopy AFF), upper section to be 8’. Full • 1 inch letters for metal rear doors wrap graphic required on lower section; upper would eventually be removed so graphic • 4 inch height white block letters, Arial font, installed on the inside lower right side of the storefront, should be different than that of lower section. Refer to illustration below. 2½” from bottom of glazing to bottom of letters. Furthest glazing panel on the right, right justified. • Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a smooth grade and not textured. Not on doors, glazing panel only BLOCK'G • BLOCK'G BLOCK'G AS REQ'D Barricade to be framed with 1”x4” wood, painted either black or white depending upon graphic. Color to be approved by Westfield Tenant Coordination. 18. Quality of Workmanship AS REQ'D 3'-0" AS REQ'D • All exterior wood surfaces must be fully primed and painted on all exposed surfaces including the ROOF 1'-6" 6'-1" edges and backs with good quality primer/paint designed for wood surfaces to ensure good General Contractor’s work shall be performed in a through, first class and workmanlike manner and shall adhesion under exterior weather conditions. Paint Specifications: Glidden, exterior latex, semi- be in good usable condition at the date of completion thereof. If in Westfield’s judgment, the General gloss finish, Fauna. ID 10YY 18/074. Contractor’s work is not completed in a first class and workmanlike manner, Tenant will not be allowed to • All plywood joints need to be screwed down to framing to eliminate bowing and warping. open until said discrepancies are corrected. • Install wind bracing as necessary to stabilize the barricade. 3'-0" 3'-4" • Barricade must be full height, to bottom of canopy or top of parapet wall.= 19. Supervision • • Barricade to be 5’ from storefront. EXIST'G BLDG Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the barricade is open to the atmosphere, top edge shall be level and secured structurally to the General Contractor shall provide a full-time supervisor on site at all times when construction is being performed in retailer’s space. Failure to comply will result in immediate work stoppage until such time as EXIST'G BLDG EXIST'G EXT. EXIST'G BLDG building. At no time whatsoever will sandbags or water barrels be allowed. said supervisor is present. WALL • • Paver flooring inside the barricade must be protected. Doors are allowed on the barricade if the premises does not have a back door. Door must be pre- EXIST'G EXT. PAVER • hung, finished, & trimmed. General Contractor must provide Facilities Director with a key to the premises. • Barricade to be 5’ from storefront. 20. Approved Design WALL PAVER PAVER PROTECTION Retailer’s store shall be constructed in accordance with the plans, which have been approved by the • Barricade graphics are required and must be approved by Westfield. Graphics must be installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72 • Top of the barricade should have a solid lid to contain noise, conditioned air, and weather. If the Tenant Coordinator. These plans will comply with all city, county, and state rules, ordinances and regulations relating thereto. If the store has not been constructed in accordance with said plans, the PROTECTION PROTECTION barricade is open to the atmosphere, top edge shall be level and secured structurally to the hours. retailer shall not be permitted to open the store for business based on the obligations under the retailer’s building. At no time whatsoever will sandbags or water barrels be allowed. lease. A copy of said plans must be kept on the job-site at all times during construction. Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in • Paver flooring inside the barricade must be protected. sections depending upon total length of barricade. Contractor to coordinate with Tenant to provide a • Doors are allowed on the barricade if the premises does not have a back door. Door must be pre- 10'-3" layout submittal to Facilities Director for approval prior to installation. hung, finished, & trimmed. 3 TYP. SECT. • General Contractor must provide Facilities Director with a key to the premises. 1 TYP. SECT. 2 TYP. SECT. • Barricade graphics are required and must be approved by Westfield. Graphics must be 21. Building Permit Barricade graphics must be full wrap, printed scrim graphic and must include the following: installed within 72 hours of barricade installation. Fines of $500/day will be levied after 72 hours. Retailer shall apply for all permits, coordinate building department submittal and pay all associated fees. • Store name and opening date on graphic returns Retailer shall apply for and obtain all approvals and permits from the local health department if required. • Website or email address for employment opportunities Barricade graphics must be framed with 1 x 4 painted wood, either white or black. Frames may be in Building permit shall be posted in retailer’s space before any work begins (i.e., demolition, rough framing, • rough plumbing or electrical). A copy of the permits must be on file with the mall management office Language related to open location in mall during construction if applicable, i.e. “Visit our Existing Store near Nordstrom.” sections depending upon total length of barricade. Bottom and top sections of barricade to be framed. Contractor to coordinate with Tenant to provide a layout submittal to Facilities Director for approval before work starts, and a copy must be placed in clear sight within the job space. SCALE: 1" = 1'-0" prior to installation. 22. Security SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" 16.2 If Tenant building Tenant canopy: 03/21/2024 Scrim description 10oz. Ultramesh, allow for a 3” bleed included outside the perimeter for mounting General Contractor shall ensure the security of premises by whatever measures it deems necessary • Barricade must be constructed of exterior-rated plywood that will not warp or delaminate with a purposes underneath the frame. including the re-keying of all locksets. 7'-11" 14'-2" smooth grade and not textured. Revision date 07.19.2021 Revision date 07.19.2021 Revision date 07.19.2021 4'-0" 3'-11" DATE: LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ LL Initials_______________ Contractor Initials_______________ Date______________ 4 1/4" 3'-7 3/4" 3'-0" 10'-10" 4 1/4" BARRICADE SPECIFICATIONS SCALE: 1/4" = 1'-0" DISHWASHING 1'-10" 18'-4" GREASE 1 TYP. SECT. INTERCEPTOR PROGRESS PRINTING HWH ALIGN W/ MULLION EXISTING 73'-6" EXISTING ROOF DRAIN BLACK IRON EXHAUST SCALE: 1" = 1'-0" OPEN OFFICE Design Review DESCRIPTION: BAR KITCHEN DISPLAY COOLER 8'-2" x 8'-0" NO. 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS BAR KITCHEN HELP @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR DINING ROOM TOILET #2 RM #4 HC TOILET RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. - RM #3 33'-0" DISPLAY CASE EMER. EXIT ONLY C L SEE SECTIONS ABOVE. POINT OF TYP. 4'-0" SECTIONS C L SALES DINING ROOM 36'-5 3/8" #1 46'-3 3/4" (V.I.F.) TOILET 45'-7 1/4" RM #2 OLD ORCHARD MALL TOILET RM #1 PROJECT: TOILET CORR. SKOKIE, IL 1 A-0.2 DINING 2" WATER NEW RESTAURANT WATER ACCESS MAIN RM ENTRY/ WAITING WASTE LINE 3'-0" 7 3/4" 112'-1" 3'-0" OUTDOOR PATIO PROTECTIVE COVERNING OVER LINE OF CANOPY PAVER FLOORING WITHIN ENTRY 9'-0" 9'-0" BARRICADE 8'-0" 6'-0" 3'-0" x 7'-0" DOOR TYP. 4'-0" SECTIONS OWNER: 4 1/4" 4 1/4" 4 1/4" 2'-0" 4 1/4" ____________ ____________ 82'-1 3/4" 40'-0 1/4" 3 1 2 122'-6 1/4" (V.I.F.) A-0.1 SHEET NAME: A-0.1 A-0.1 4 1/4" THK BARRICADE WALL- 2 X 4 18 GA. MTL STUDS WATER 2 PROJECT TRUE @ 16" O.C. w/ 5/8" T & G SMOOTH GRADE EXTERIOR 2 SUPPLY Barricade Plan NORTH NORTH RATED PLYWD SHTS EXTERIOR SIDE ONLY TYP. - SEE SECTIONS ABOVE. A-0.2 BARRICADE PLAN SCALE: 1/4" = 1'-0" A-0.2 PROJECT: 7438 SCALE: AS NOTED DATE: 08/20/2023 A-0.1 20'-0" 14'-6" 1'-9" 3'-7 1/2" 13'-3 3/4" 6'-8 1/4" 4'-0" TYP. 4 X 8 PLYWD SHTS 20'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" SCALE: 1/4" = 1'-0" 3068 SCALE: 1/4" = 1'-0" TYP. 4 X 8 PLYWD SHTS TYP. 4 X 8 PLYWD SHTS EAST BARRICADE ELEVATION NORTH BARRICADE ELEVATION 12'-0" 9'-10" 1'-5" 11'-3" EL. + 11'-3" EL. +/- 0'-0" BOT MTL DECK EL. + 9'-10" FINISHED FLOOR FINISHED CEILING 17'-11" 2'-4" EL. +/- 0'-0" EL. + 20'-3" EL. + 13'-0" TOP PARAPET FINISHED FLOOR FINISHED CEILING PROGRESS PRINTING OWNER: PROJECT: ALEXIOS GEORGES NEW RESTAURANT LASZLO SIMOVIC, ARCHITECTS, L.L.C. PROJECT: 7438 4999 OL ORCHARD 6512 N. ARTESIAN AVE. SHOPPING CTR, SUITE A28 CHICAGO, IL. 60645-5328 DATE: 08/20/2023 SCALE: AS NOTED Barricade Elevations SHEET NAME: SKOKIE, IL 60077 4999 OL ORCHARD EMAIL: LASZLO@LASZLOARCH.COM SHOPPING CTR, SUITE A28 Design Review 03/21/2024 FAX: 773-338-2226 TEL: 773-338-2225 SKOKIE, IL 60077 A-0.1 NO. DESCRIPTION: DATE: LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 K10 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 MAGGIANO'S BSMT SLAB ON GRADE ROOF LEVEL BUILDING ABOVE EMAIL: LASZLO@LASZLOARCH.COM FAX: 773-338-2226 1'-6" 6'-1" 3'-4" 1 ALIGN A-13 10'-3" K10.7 14'-2" 03/21/2024 DATE: 10'-10" DISHWASHING 1'-10" 18'-4" GREASE INTERCEPTOR HWH PROGRESS PRINTING EXISTING 73'-6" EXISTING ROOF DRAIN BLACK IRON EXHAUST OPEN OFFICE Design Review DESCRIPTION: VELVET BANQUET #1 VELVET BANQUET #2 K11 BAR KITCHEN DISPLAY COOLER 8'-2" x 8'-0" NO. BAR KITCHEN HELP DINING ROOM TOILET #2 RM #4 K11.4 2 HC TOILET RM #3 A-12 33'-0" DISPLAY 3 CASE EMER. EXIT ONLY C L LEATHER BANQUET #3 LEATHER BANQUET #4 POINT OF C L SALES DINING ROOM 36'-5 3/8" #1 TOILET RM #2 1 OLD ORCHARD MALL A-12 TOILET RM #1 PROJECT: rendering TOILET view #2 CORR. rend view e#ring 1 SKOKIE, IL DINING rendering view #3 2" WATER WATER NEW RESTAURANT MAIN ACCESS RM F.D. ENTRY/ WAITING WASTE LINE K12 L11.9 112'-1" ALIGN OUTDOOR PATIO NEW COLUMNS AND COLUMN LINE PER STRUCTURAL DRAWINGS ENTRY NEW WATER LIN NEW SEWER LINE BY OWNER 2 1 BY OWNER - ROUTED UNDER 1 A-10 A-11 BOTTOMOF A-10 FOOTING OWNER: 2 ____________ A-11 ____________ XX KA KB KB.7 KC KC.6 KD SHEET NAME: WATER SUPPLY New Floor Plan PROJECT TRUE NORTH NORTH NEW 1ST FLOOR PLAN PROJECT: 7438 SCALE: 1/4" = 1'-0" 3,855 SF LEASED SPACE SCALE: AS NOTED DATE: 08/20/2023 A-6 LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 K10 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 EMAIL: LASZLO@LASZLOARCH.COM FAX: 773-338-2226 EXIST'G RUBBER ROOF 2 A-13 K10.7 03/21/2024 DATE: NOTE: PROVIDE OPENING AT BOTTOM OF RETURN WALL ALIGNING W/ TOP' OF LOWER PARAPET WALL TO ALLOW EXIST'G DRAINAGE TO REMAIN. NOTE: ALIGN TOP OF RETURN WALL WITH TOP OF PARAPET WALL EXISTING ROOF DRAIN PROGRESS PRINTING EXISTING BLACK IRON EXHAUST Design Review DESCRIPTION: K11 NEW EXTRUDED ALUMINUM NO. COPING, COLOR TO MATCH EXTERIOR FINISH, TYP. EXIST'G 2ND FLOOR (N.I.C.) K11.4 2 A-12 EXIST'G RUBBER ROOF REPAIR / REPLACE AS NEW RUBBER REQUIRED ROOF TO MATCH EXIST'G 4999 OL ORCHARD 1 A-12 PROJECT: SHOPPING CTR, SUITE A28 NEW RESTAURANT SKOKIE, IL 60077 NEW EXTRUDED ALUMINUM COPING, COLOR TO MATCH EXTERIOR FINISH, TYP. K12 OWNER: 2 1 1 ALEXIOS GEORGES A-10 A-11 A-10 4999 OL ORCHARD SHOPPING CTR, SUITE A28 SKOKIE, IL 60077 2 A-11 XX KA KB KB.7 KC KC.6 KD SHEET NAME: KE New Roof Plan PROJECT TRUE NORTH NORTH NEW ROOF PLAN PROJECT: 7438 SCALE: 1/4" = 1'-0" 3,855 SF LEASED SPACE PARTITION LEGEND SCALE: AS NOTED WALL TO REMAIN DATE: 08/20/2023 WALL TO BE REMOVED WALL FINISH TO BE REMOVED STUDS TO REMAIN A-7 WALL TO BE CONSTRUCTED PARTITION CONSTR. TYPE INCLUD'G UL # - SEE SHEET A-__ 0 5 10 15 20 FT SCALE 1/4" = 1'-0" LASZLO SIMOVIC, ARCHITECTS, L.L.C. TEL: 773-338-2225 EXTRUDED ALUMINUM EXTRUDED ALUMINUM COPING, COLOR TO MATCH COPING, COLOR TO MATCH PANELS, TYP. PANELS, TYP. EL. + 20'-4" EL. + 20'-4" TOP PARAPET TOP PARAPET 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 4'-2" 4'-1" STONE PANEL, TYP. STONE PANEL, TYP. 7'-6" NEW WINDOW SYSTEM WITH BLACK ALUMINUM FRAMING, TYP. BLACK ALUMINUM CLAD STEEL 1'-9" CANOPY SYSTEM WITH TRANSULUCENT ROOF PANELS, TYP. EMAIL: LASZLO@LASZLOARCH.COM 4'-2" 1'-6" EL. + 13'-0" FAX: 773-338-2226 FINISHED CEILING 1'-0" 1'-0" 2" 2" 1'-6" 2" 20'-4" 4'-2" 3'-3" 20'-4" 2" 13'-0" 4'-2" 11'-10" 11'-10" 11'-10" 10'-0" PROVIDE 3/4" STAINLESS STEEL CHANNEL AT CONNECTION BETWEEN NEW EXTERIOR FACADE AND EXISTING 8'-1" EXTERIOR FACADE 2'-9 3/4" 03/21/2024 10" 2" EL. +/- 0'-0" GRANITE BASE FINISHED FLOOR DATE: COLOR TO MATCH FACADE TYP. 112'-3" NEW PARTIAL NORTH ELEVATION SCALE: 1/4" = 1'-0" PROGRESS PRINTING NEW PARTIAL EAST ELEVATION Design Review DESCRIPTION: SCALE: 1/4" = 1'-0" NO. EXTRUDED ALUMINUM COPING, COLOR TO MATCH PANELS, TYP. EL. + 20'-4" TOP PARAPET STONE PANEL, TYP. NEW WINDOW SYSTEM WITH BLACK ALUMINUM FRAMING, TYP. BLACK ALUMINUM CLAD STEEL PROVIDE 3/4" STAINLESS STEEL CANOPY SYSTEM WITH TRANSULUCENT CHANNEL AT CONNECTION BETWEEN NEW EXTERIOR FACADE AND EXISTING ROOF PANELS, TYP. EXTERIOR FACADE 7'-0" EL. + 13'-0" FINISHED CEILING 1'-0" 4999 OL ORCHARD NOTE: PATCH & REPAIR EXISTING CANOPY TO MATCH EXISTING EXACTLY, COLOR, SIZE, SHAPE, ETC. (USE EXIST'G MANUF.) PROJECT: SHOPPING CTR, SUITE A28 NEW WINDOW TO MATCH EXISTING EXACTLY, COLOR, 11'-10" SIZE, SHAPE, ETC. 9'-6" SKOKIE, IL 60077 EXISTING DECORATIVE NEW RESTAURANT COLUMN, ETC. EL. +/- 0'-0" FINISHED FLOOR GRANITE BASE COLOR TO MATCH PROVIDE NEW DECORATIVE COLUMN TO MATCH EXIST'G FACADE TYP. EXACTLY, SIZE, SHAPE, COLOR, ETC. NEW PARTIAL EAST ELEVATION SCALE: 3/8" = 1'-0" OWNER: EL. + 20'-4" ALEXIOS GEORGES TOP PARAPET 4999 OL ORCHARD SHOPPING CTR, SUITE A28 SKOKIE, IL 60077 SHEET NAME: New Elevations PROJECT: 7438 PARTITION LEGEND SCALE: AS NOTED WALL TO REMAIN DATE: 08/20/2023 WALL TO BE REMOVED WALL FINISH TO BE REMOVED STUDS TO REMAIN A-8 WALL TO BE CONSTRUCTED PARTITION CONSTR. TYPE INCLUD'G UL # - SEE SHEET A-__ 0 5 10 15 20 FT SCALE 1/4" = 1'-0" LASZLO SIMOVIC, ARCHITECTS, L.L.C. SLOPE DN TEL: 773-338-2225 RETURN WALL SEE ROOF PLAN OPEN AT BOTTOM EXIST'G RUBBER NEW RUBBER SLOPE DN SLOPE DN PROVIDE 3/4" BRONZE ROOF REVEAL AT CONNECTION BETWEEN ROOF TO 6512 N. ARTESIAN AVE. CHICAGO, IL. 60645-5328 NEW EXTERIOR FACADE AND EXISTING MATCH EXIST'G EXTERIOR FACADE XX EMAIL: LASZLO@LASZLOARCH.COM FAX: 773-338-2226 K10.7 K11 K11.4 K12 L11.9 PROJECT TRUE NORTH NORTH 2 NEW PARTIAL ROOF PLAN SCALE: 3/8" = 1'-0" INFILL EXISTING OPENING WITH C 03/21/2024 MATERIALS TO MATCH EXISTING L EXACTLY AT THIS SIDE EMER. EXIT ONLY DATE: XX PROVIDE 3/4" BRONZE PROGRESS PRINTING REVEAL AT CONNECTION BETWEEN PROVIDE NEW WINDOW TO NEW EXTERIOR FACADE AND EXISTING MATCH EXISTING, EXACTLY. EXTERIOR FACADE (COLOR, SHAPE, SIZE, ETC.) Design Review DESCRIPTION: PROVIDE NEW DECORATIVE COLUMN TO MATCH EXIST'G EXACTLY, SIZE, SHAPE, COLOR, ETC. K10.7 K11 K11.4 K12 L11.9 NO. PROJECT TRUE NORTH NORTH 1 NEW PARTIAL 1ST FLOOR PLAN SCALE: 3/8" = 1'-0" K10.7 K11 K11.4 K12 EXTRUDED ALUMINUM COPING, COLOR TO MATCH PANELS, TYP. EL. + 20'-4" TOP PARAPET 3'-1" 8'-7 1/4" STONE PANEL, TYP. 4999 OL ORCHARD 1'-5 3/4" 2'-7 7/8" BLACK ALUMINUM CLAD STEEL 7 1/8" 7" CANOPY SYSTEM WITH TRANSULUCENT PROJECT: SHOPPING CTR, SUITE A28 PROVIDE 3/4" BRONZE CHANNEL AT ROOF PANELS, TYP. CONNECTION BETWEEN NEW EXTERIOR FACADE AND EXISTING EXTERIOR FACADE NEW WINDOW SYSTEM WITH 11 3/4" 6'-7 3/4" 11 3/4" BLACK ALUMINUM FRAMING, TYP. EL. + 13'-0" FINISHED CEILING SKOKIE, IL 60077 1'-0" NEW RESTAURANT EXISTING DECORATIVE 14'-7 1/8" COLUMN, ETC. NEW WINDOW TO MATCH EXISTING EXACTLY, COLOR, 11'-10" OWNER: SIZE, SHAPE, ETC. GRANITE BASE, COLOR TO MATCH ALEXIOS GEORGES STONE PANELS, TYP. 4999 OL ORCHARD EL. +/- 0'-0" SHOPPING CTR, SUITE A28 SKOKIE, IL 60077 FINISHED FLOOR PROVIDE NEW DECORATIVE COLUMN TO MATCH EXIST'G FULLY ADHERED STONE BASE EXACTLY, SIZE, SHAPE, COLOR, ETC. CEMTENTIOUS FIBER BOARD PANELS, SMOOTH, WITH GROOVES TO MATCH EXISITNG TO MATCH EXISTING NEW PARTIAL EAST ELEVATION SCALE: 3/8" = 1'-0" SHEET NAME: Enlarged Front Elevation PROJECT: 7438 SCALE: AS NOTED DATE: 08/20/2023 A-13
Appearance Commission — Skokie, IL